This unit relates to the control of insects and other pests by means of fumigation of grain and seed in storage and crops and plants grown in protected environments. These storage areas and protected environments may be deemed to be confined spaces "in situ" or be deemed to be confined spaces because of the impact of the fumigation activities.
This unit covers the process of fumigation of grain, seed, crops and plants in enclosed spaces and defines the standard required to: assess the need for fumigation; select appropriate fumigant and application method; prepare and monitor storage facility and equipment; apply fumigant; restore facility and clean equipment; record work activities.
You may want to include more information here about the target group and the purpose of the assessments (eg formative, summative, recognition)
Employability Skills
This unit contains employability skills.
Evidence Required
List the assessment methods to be used and the context and resources required for assessment. Copy and paste the relevant sections from the evidence guide below and then re-write these in plain English.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The evidence required to demonstrate competency in this unit must be relevant to workplace operations and satisfy holistically all of the requirements of the performance criteria and required skills and knowledge and include achievement of the following:
assess the need for fumigation
select appropriate fumigant and application method
prepare and monitor storage facility and equipment
apply fumigant
restore facility and clean equipment
record work activities.
Context of and specific resources for assessment
Competency requires the application of work practices under work conditions. Selection and use of resources for some worksites may differ due to the regional or enterprise circumstances.
Submission Requirements
List each assessment task's title, type (eg project, observation/demonstration, essay, assingnment, checklist) and due date here
Assessment task 1: [title] Due date:
(add new lines for each of the assessment tasks)
Assessment Tasks
Copy and paste from the following data to produce each assessment task. Write these in plain English and spell out how, when and where the task is to be carried out, under what conditions, and what resources are needed. Include guidelines about how well the candidate has to perform a task for it to be judged satisfactory.
Required skills
prepare fumigants
conduct pre-operational checks, clean up and storage of fumigation equipment and PPE
prepare and seal facility
set up and calibrate fumigation equipment
apply fumigants
check for residual fumigant gas
use literacy skills to read, interpret and follow organisational policies and procedures, follow sequenced written instructions, record accurately and legible information collected and select and apply procedures for a range of tasks
use oral communication skills/language competence to fulfil the job role as specified by the organisation, including questioning techniques, active listening, clarifying information and consulting with supervisors as required
use numeracy skills to estimate, calculate and record routine workplace measures
use interpersonal skills to work with and relate to people from a range of cultural, social and religious backgrounds and with a range of physical and mental abilities.
Required knowledge
primary and secondary pests relevant to grain, seed, crops or plants to be treated
threshold pest levels and cost benefit options
fumigant free options for pest control including Integrated Pest/Resistance Management principles
fumigant label and MSDSs formats
interpretation and application of fumigant label requirements
factors and considerations in relation fumigation of relevant grain, seed, crops and plants
techniques for sealing facility
types and application of personal protective equipment
legislation and regulations including OHS and licensing requirements in relation to fumigant use
confined space regulations including, signage, gas detection and entry procedures
features, functions, calibration and set up of fumigation equipment
risk factors including human and animal health, weather, leakage, spillage and environmental
assessment of residual gas and safe re-entry periods
consequence of fumigant residues and Maximum Residue Limits (MRLs)
ventilation processes
requirements for disposal of excess fumigants, clearing spillages and equipment clean up.
The range statement relates to the unit of competency as a whole.
Operating procedures may include:
Standard Operating Procedures (SOPs) used for fumigation in storage areas and in protected environments.
Copy and paste from the following performance criteria to create an observation checklist for each task. When you have finished writing your assessment tool every one of these must have been addressed, preferably several times in a variety of contexts. To ensure this occurs download the assessment matrix for the unit; enter each assessment task as a column header and place check marks against each performance criteria that task addresses.
Observation Checklist
Tasks to be observed according to workplace/college/TAFE policy and procedures, relevant legislation and Codes of Practice
Yes
No
Comments/feedback
Ascertain the threshold level of infestation against quality requirements and industry practice.
Determine the need for fumigation as an option within an Integrated Pest Management (IPM) and IRM strategy.
Determine the appropriate fumigation method with regard to pest type, facility and storage/growing conditions.
Undertake a cost-benefit analysis of fumigation.
Select method of fumigant application to suit type of pests, facility and grain/plant type in accordance with manufacturer's specifications, environmental, legislative, Occupational Health and Safety (OHS) requirements and industry practice.
Determine type of fumigant and application rate in accordance with manufacturer's specifications, standards and environmental, legislative, OHS and industry practice.
Assess appropriateness of facility and conditions for selected fumigation method.
Identify and report any factors affecting the safe application of fumigants.
Determine facility capacity to ensure fumigation conditions are in accordance with manufacturer's specifications and environmental, legislative, OHS and industry practice.
Assess hazards and control risks in relation to the use of fumigants in accordance with legislative, environmental, OHS requirements and industry practice.
Establish security measures to control access during fumigation and prescribed re-entry periods in accordance with label directions.
Erect signage and barriers to control risk of inadvertent entry to facility.
Apply sealing methods as appropriate to contain fumigant in accordance with label and industry practice.
Check seal, calculate volume of storage facility, and take appropriate measurement to ensure the required concentration of fumigant is retained in accordance with label directions.
Set up emergency and confined spaces systems in accordance with legislative and OHS and requirements.
Select and use appropriate personal protective equipment in accordance with label and Material Safety Data Sheets (MSDSs) requirements.
Select application equipment appropriate for the fumigation in accordance with label directions and industry practice.
Check operational effectiveness of equipment in accordance with manufacturer's specifications and industry practice.
Calibrate fumigation equipment to application rate in accordance with label directions.
Prepare fumigant in accordance with label legislative and OHS requirements and industry practice.
Apply fumigation using appropriate equipment, fumigation methods and sealing methods in accordance with label and industry practice.
Respond to emergency situations using emergency response procedures in accordance with legislative and OHS requirements and industry practice.
Monitor fumigation site during exposure time and ventilation to prevent unauthorised access in accordance with legislative and OHS requirements and industry practice.
Maintain integrity of seals throughout the active fumigation period in accordance with label, legislative and OHS requirements and industry practice.
Establish ventilation and re-entry times and control risks to public health and safety in accordance with label, legislative, OHS requirements and industry practice.
Ventilate facility to remove fumigant in a safe and controlled manner in accordance with label, legislative, OHS and industry practice.
Test for evidence of residual gas using appropriate equipment.
Notify appropriate person(s) of any further risk control measures required in accordance with label, legislative, OHS and industry practice.
Collect and remove all equipment, fumigants and waste in accordance with label, legislative, OHS and industry practice.
Remove signage and barriers when facility is available for re-use in accordance with legislative and industry practice.
Restore storage facility in accordance with legislative and industry practice.
Clean, decontaminate, check and store equipment and Personal Protective Equipment (PPE) in accordance with manufacturer's specifications, OHS and industry practice.
Transport and store fumigants in accordance with label, OHS and industry practice.
Dispose of all waste in accordance with label, legislative, OHS environmental and industry practice.
Record details of fumigant applications in accordance with legislative and quality assurance requirements and industry practice.
Record and report gas escapes, safety incidents or poisoning to the appropriate person or authority in accordance with legislative requirements.
Forms
Assessment Cover Sheet
AHCCHM301A - Conduct fumigation in enclosed spaces
Assessment task 1: [title]
Student name:
Student ID:
I declare that the assessment tasks submitted for this unit are my own work.
Student signature:
Result: Competent Not yet competent
Feedback to student
Assessor name:
Signature:
Date:
Assessment Record Sheet
AHCCHM301A - Conduct fumigation in enclosed spaces
Student name:
Student ID:
Assessment task 1: [title] Result: Competent Not yet competent
(add lines for each task)
Feedback to student:
Overall assessment result: Competent Not yet competent