List the assessment methods to be used and the context and resources required for assessment. Copy and paste the relevant sections from the evidence guide below and then re-write these in plain English.
Elements describe the essential outcomes. | Performance criteria describe the performance needed to demonstrate achievement of the element. |
1 | Prepare for installation | 1.1 | Applicable work health and safety (WHS), legislative and organisational requirements relevant to installing resilient sheet to walls are verified and complied with |
1.2 | Instructions and/or plans are read and interpreted to identify process required to complete work tasks |
1.3 | Substrate condition is assessed for suitability for installation of resilient coverings to the walls |
1.4 | Suitable adhesives, trims and accessories are selected |
1.5 | Tools, equipment and materials are selected and checked prior to use to ensure that they are appropriate for the work, serviceable and in a safe condition |
1.6 | Sequence of work is planned, including the starting point, to ensure efficiency and quality of installation |
2 | Set out floor coverings | 2.1 | Resilient sheet to be installed is checked against work order |
2.2 | Resilient sheets are acclimatised according to manufacturer recommendations |
2.3 | Resilient sheets for fixing are organised and used in accordance with relevant safety management requirements |
2.4 | Working lines and starting point are established |
2.5 | Pre-form fillet is cut and fitted, if required |
2.6 | Feathering systems and applications are prepared and applied in accordance with the installation plan |
3 | Install resilient sheet | 3.1 | Resilient sheet are laid out to meet directional sequence, pattern match, specification requirements and to minimise waste and joins as appropriate |
3.2 | The aesthetics of the materials is maximised, where appropriate, matching grains, colours and patterns |
3.3 | Materials are cut to length and size, allowing for final adjustment, trimming and welding processes |
3.4 | Header and/or perimeter contact adhesive is applied to surfaces |
3.5 | Adhesive is applied to the body of the walls as specified by the adhesive manufacturer |
3.6 | Resilient sheet is positioned in accordance with the plan, pressed out and hand-rolled |
3.7 | Resilient sheet is heated to form required profiles |
3.8 | Seams are prepared and welded in accordance with the plan, manufacturer instructions and industry standards |
3.9 | Joins and/or seams are trimmed and finished to industry standards |
3.10 | Resilient sheet are sealed to floor coverings, door and window frames, as well as fixtures and fittings in wet area installations |
3.11 | Completed installation is checked for flaws in installation and materials and faults rectified following workplace procedures |
4 | Complete housekeeping | 4.1 | Unused materials are stored or recycled as required |
4.2 | Tools and equipment are cleaned and stored appropriately |
4.3 | Work area is cleaned and rubbish disposed of appropriately |
4.4 | Workplace documentation is completed |
Interpret work order and locate and apply relevant information
Apply safe handling requirements for equipment, products and materials, including use of personal protective equipment
Identify materials used in the work process
Follow work instructions, operating procedures and inspection processes to:
minimise the risk of injury to self or others
prevent damage to goods, equipment and products
maintain required production output and product quality
Complete a minimum of:
one (1) installation of a wet wall resilient wall covering installation using a horizontal installation system, including internal and external corners to walls, the covering of window reveals, and sealing to door frames and fittings
one (1) installation of a wet wall resilient wall covering installation using a vertical installation system, including internal and external corners to walls, the covering of window reveals and sealing to door frames and fittings
Use mathematical ideas and techniques to correctly complete measurements, calculate area and estimate material requirements
Communicate ideas and information to enable confirmation of work requirements and specifications and the reporting of work outcomes and problems, interpret basic plans and follow safety procedures
Avoid backtracking, work flow interruptions or wastage
Work with others and in a team by recognising dependencies and using cooperative approaches to optimise work flow and productivity
State or territory WHS legislation, regulations, standards and codes of practice relevant to installing resilient sheet to walls
Organisational and site standards, requirements, policies and procedures for installing resilient sheet to walls
Environmental protection requirements
Established communication channels and protocols
Relevant problem identification and resolution
Types of tools and equipment and procedures for their safe use, operation and maintenance
Characteristics of materials, products and defects
Set-up and operation of equipment
Products assembly techniques
Procedures for the recording, reporting and maintenance of workplace records and information
Appropriate mathematical procedures for estimation and measurement
Type, characteristics, uses and limitations of:
weldable resilient wall coverings
resilient wall covering installation adhesives
Types and uses of resilient wall covering installation tools and equipment
Workplace safety system requirements related to resilient wall covering installation
Characteristics and requirements of substrate preparation for wall coverings
Work flow in relation to fixing, welding and finishing of resilient wall coverings
Assessors must:
hold training and assessment competencies as determined by the National Skills Standards Council (NSSC) or its successors
have vocational competency in the furnishing industry at least to the level being assessed with broad industry knowledge and experience, usually combined with a relevant industry qualification
be familiar with the current skills and knowledge used and have relevant, current experience in the furnishing industry.
Assessment methods must confirm consistency of performance over time rather than a single assessment event and in a range of workplace relevant contexts.
Assessment must be by observation of relevant tasks with questioning on underpinning knowledge and, where applicable, multimedia evidence, supervisor’s reports, projects and work samples.
Assessment is to be conducted on single units of competency or in conjunction with other related units of competency. Foundation skills are integral to competent performance in the unit and should not be assessed separately.
Assessment must occur on the job or in a workplace simulated facility with relevant process, equipment, materials, work instructions and deadlines.
Access is required to materials, equipment and specifications relevant to installing resilient sheet to walls.