List the assessment methods to be used and the context and resources required for assessment. Copy and paste the relevant sections from the evidence guide below and then re-write these in plain English.
ELEMENTS | PERFORMANCE CRITERIA |
Elements describe the essential outcomes | Performance criteria describe the performance needed to demonstrate achievement of the element. Where bold italicised text is used, further information is detailed in the range of conditions section. |
1. Plan and prepare for work | 1.1 Determine work requirements as outlined in the standard operating procedure. 1.2 Select and check equipment and tools required to meet safety requirements of task and site. 1.3 Select, fit and use personal protective equipment. |
2. Monitor system performance | 2.1 Monitor UV irradiation disinfection processes. 2.2 Collect process samples and conduct standard tests. 2.3 Maintain and monitor relevant WHS requirements. |
3. Maintain and operate UV irradiation disinfection system | 3.1 Carry out routine inspections of system components. 3.2 Clean and replace system components as required. 3.3 Operate UV lamp sequencing. |
4. Complete documentation | 4.1 Collect and report process data. 4.2 Report observations outside defined parameters for further action. |
Evidence required to demonstrate competence must satisfy all of the requirements of the elements and performance criteria. If not otherwise specified the candidate must demonstrate evidence of performance of the following on at least one occasion.
using cleaning chemicals
applying policies, standard operating procedures and regulatory standards
performing calculations
identifying control system faults and operational problems
identifying hazards
interpreting safety data sheets (SDS)
monitoring, operating and reporting on UV irradiation disinfection systems
scheduling work
selecting and using appropriate tools and equipment, including personal protective equipment
monitoring UV irradiation disinfection systems
collecting process samples
performing standard tests, including at least one of:
UVT
turbidity
suspended solids
iron
lamp intensity
hardness
total organic carbon
maintaining and operating UV irradiation disinfection systems
Evidence required to demonstrate competence must satisfy all of the requirements of the elements and performance criteria. If not otherwise specified the depth of knowledge demonstrated must be appropriate to the job context of the candidate.
properties of UV irradiation
microbiological water quality guidelines
UV irradiation disinfection system layout, including components
lockout procedures for mechanical and electrical installations
policies, standard operating procedures and legislation
communication systems
safe use of cleaning chemicals and prevention of associated hazards
risk factors and potential hazards associated with UV irradiation systems
UV irradiation generation equipment operation, capacity and limitations
effects of weather and conditions on operation of site or plant
SDS
Competency should be assessed in an actual workplace or in a simulated environment, with access to equipment and infrastructure appropriate to the outcome. Competency should be demonstrated over time to ensure the candidate is assessed across a variety of situations.
Some components of this unit require assessment in a workplace environment therefore the unit is not suitable for fully external or electronic based assessment.
Assessors must satisfy the NVR/AQTF mandatory competency requirements for assessors.