This unit is appropriate for those working in an operational role at worksites within:

Metalliferous mining

This unit covers the monitoring and maintenance of flue gas efficiency in the metalliferous mining industry. It includes preparing for plant and equipment operation, maintaining efficient operation of gas plant and systems, maintaining plant and equipment efficiency, and shutting down plant and equipment. Licensing, legislative, regulatory and certification requirements that apply to this unit can vary between states, territories, and industry sectors. Relevant information must be sourced prior to application of the unit.

You may want to include more information here about the target group and the purpose of the assessments (eg formative, summative, recognition)

Prerequisites

Not applicable.


Co-Requisites

Not applicable.


Employability Skills

This unit contains employability skills.




Evidence Required

List the assessment methods to be used and the context and resources required for assessment. Copy and paste the relevant sections from the evidence guide below and then re-write these in plain English.

The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.

Overview of assessment

Critical aspects for assessment and evidence required to demonstrate competency in this unit

The evidence required to demonstrate competency in this unit must be relevant to worksite operations and satisfy all of the requirements of the performance criteria, required skills and knowledge and the range statement of this unit and include evidence of the following:

knowledge of the requirements, procedures and instructions for monitoring and maintaining flue gas efficiency

implementation of requirements, procedures and techniques for the safe, effective and efficient completion of flue gas efficiency monitoring and maintenance

working with others to undertake and complete the monitoring and maintenance of flue gas efficiency in a way that meets all of the required outcomes

consistent timely completion of flue gas efficiency monitoring and maintenance that safely, effectively and efficiently meets the required outcomes

Context of and specific resources for assessment

This unit must be assessed in the context of the work environment. Where personal safety or environmental damage are limiting factors, assessment may occur in a simulated environment provided it is realistic and sufficiently rigorous to cover all aspects of workplace performance, including task skills, task management skills, contingency management skills and job role environment skills.

Assessment of this competency requires typical resources normally used in a resources and infrastructure sector environment. Selection and use of resources for particular worksites may differ due to the site circumstances.

The assessment environment should not disadvantage the participant. For example, language, literacy and numeracy demands of assessment should not be greater than those required on the job.

Customisation of assessment and delivery environment to sensitively accommodate cultural diversity.

Aboriginal people and other people from a non English speaking background may have second language issues.

Where applicable, physical resources should include equipment modified for people with disabilities. Access must be provided to appropriate learning and/or assessment support when required.

Method of assessment

This unit may be assessed in a holistic way with other units of competency. The assessment strategy for this unit must verify required knowledge and skill and practical application using more than one of the following assessment methods:

written and/or oral assessment of the candidate's required knowledge

observed, documented and/or first hand testimonial evidence of the candidate's:

implementation of appropriate requirement, procedures and techniques for the safe, effective and efficient achievement of required outcomes

consistent achievement of required outcomes

first hand testimonial evidence of the candidate's:

working with others to undertake and complete the monitoring and maintenance of flue gas efficiency

Guidance information for assessment

Consult the SkillsDMC User Guide for further information on assessment including access and equity issues.


Submission Requirements

List each assessment task's title, type (eg project, observation/demonstration, essay, assingnment, checklist) and due date here

Assessment task 1: [title]      Due date:

(add new lines for each of the assessment tasks)


Assessment Tasks

Copy and paste from the following data to produce each assessment task. Write these in plain English and spell out how, when and where the task is to be carried out, under what conditions, and what resources are needed. Include guidelines about how well the candidate has to perform a task for it to be judged satisfactory.

Required skills

Specific skills are required to achieve the Performance Criteria of this unit, particularly for its application in the various circumstances in which this unit may be used. This includes the ability to carry out the following, as required to monitor and maintain flue gas efficiency:

apply legislative, organisation and site requirements and procedures for monitoring and maintaining flue gas efficiency

troubleshoot

apply precautions necessary for safe working

use protective clothing and equipment

apply operating procedures

report faults

recognise limits of authority

apply team working practices

communicate information

use hand and power tools

Required knowledge

Specific knowledge is required to achieve the Performance Criteria of this unit, particularly for its application in the various circumstances in which this unit may be used. This includes knowledge of the following, as required to monitor and maintain flue gas efficiency:

principles of flue gas plant operation

gas paths

environmental protection requirements

hygiene management

dust collection and disposal systems and plant

plant inspections

insulation (refractory)

combustion principles

methods of resolving gas problems

ability to isolate problem to item of equipment

The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.

Relevant compliance documentation may include:

legislative, organisational and site requirements and procedures

manufacturer's guidelines and specifications

Australian standards

code of practice

Employment and workplace relations legislation

Equal Employment Opportunity and Disability Discrimination legislation

Legislation may include Acts and regulations dealing with:

mining safety and health

mine inspection

OHS

explosives

environment

Auxiliary equipment may be anything that is portable and mobile that is not part of the fixed infrastructure, and may include:

weighers

compressors

distribution control systems

feeders

gantry cranes and attachments and other mobile equipment

hand and power tools

hoses (water and air)

pumps

Pre-start checks may include:

availability of equipment

detection of conditions that are unusual

job requirements

personnel availability

walk through plant

communications

Environmental issues may include:

drainage

dust (dump)

emissions

flora and fauna

hazardous chemicals

noise

recycling

run-off

spills

waste management and disposal

water quality

Equipment start-up checks and procedures may include:

draft systems

cameras and monitors

checking distribution control system (DCS)

chutes

display instruments, lights and gauges

equipment stop engine lights

hydraulic system

isolations

lighting

suppression systems

valves

visual and audio warning devices and lights

Cleaning methods may include:

degreasing

forced air

sweeping

Monitoring may include:

blockages and spillages

feed rates

overloads

pressures

power draw

wear and tear

emissions

levels

temperatures

moisture content

on-stream analysis (OSA)

filtering

corrosion

Plant alarms may include those for:

alarms

distribution control systems

mimic panel

screens

temperature

flow

weight

pressure

Minor plant maintenance may include:

lubrication

minor adjustments to operational plant

cleaning plant, equipment and work area

installation/removal of devices to allow safe maintenance

fixing leaks

Copy and paste from the following performance criteria to create an observation checklist for each task. When you have finished writing your assessment tool every one of these must have been addressed, preferably several times in a variety of contexts. To ensure this occurs download the assessment matrix for the unit; enter each assessment task as a column header and place check marks against each performance criteria that task addresses.

Observation Checklist

Tasks to be observed according to workplace/college/TAFE policy and procedures, relevant legislation and Codes of Practice Yes No Comments/feedback
Access, interpret and apply compliance documentation relevant to the work activity 
Receive, interpret and clarify shift changeover details 
Establish and maintain communication with other personnel using approved communication methods 
Select personal protective equipment appropriate for work activities 
Select appropriate auxiliary equipment for work activities 
Carry out equipment visual pre-start checks to ensure equipment is ready for operation 
Identify, address and report potential risks and hazards 
Identify, address and report environmental issues 
Follow emergency procedures to ensure safety of personnel and plant 
Use approved dust suppression and extraction methods 
Ventilate work area before entry 
Carry out plant and equipment start-up checks and procedures according to plant/equipment configurations and system requirements 
Operate and maintain air operated breathing equipment for flue gas plant off-line entry 
Control mixing chamber temperatures by automatic or manual methods 
Clean, inspect and maintain gas cooling plant in operational condition to ensure efficient gas cooling 
Monitor and control flue gas temperature control additive to maintain mixing chamber temperature 
Clean plant to maintain condition of all equipment to ensure safe and efficient operations 
Identify and report hazards to maintain a safe working environment 
Interpret and respond to plant alarms, take remedial actions and notify appropriate personnel 
Check and adjust plant condition to maintain efficient operation 
Maintain plant hygiene and safety 
Changeover and adjust plant to meet operational and maintenance requirements 
Carry out minor plant maintenance and lubrication tasks 
Provide support for maintenance personnel where necessary to organisation's requirements 
Shutdown or isolate plant/equipment based on process and safety requirements 
Perform post shutdown or isolation checks 
Pass on shift changeover details to oncoming shift 

Forms

Assessment Cover Sheet

RIIPSM309A - Monitor and maintain flue gas efficiency
Assessment task 1: [title]

Student name:

Student ID:

I declare that the assessment tasks submitted for this unit are my own work.

Student signature:

Result: Competent Not yet competent

Feedback to student

 

 

 

 

 

 

 

 

Assessor name:

Signature:

Date:


Assessment Record Sheet

RIIPSM309A - Monitor and maintain flue gas efficiency

Student name:

Student ID:

Assessment task 1: [title] Result: Competent Not yet competent

(add lines for each task)

Feedback to student:

 

 

 

 

 

 

 

 

Overall assessment result: Competent Not yet competent

Assessor name:

Signature:

Date:

Student signature:

Date: