Prerequisite Unit(s)
2)
2.1) Competencies
Granting competency in this unit shall be made only after competency in the following unit(s) has/have been confirmed.
UEENEEJ134A Design heating, ventilation and air conditioning (HVAC) systems and select components
UEENEEJ138A Analyse vibration and noise in refrigeration and air conditioning systems
UEENEEJ165A Evaluate thermodynamic and fluid parameters of refrigeration systems
UEENEEJ164A Analyse the operation of HVAC air and hydronic systems
UEENEEJ192A Analyse the psychrometric performance of HVAC/R systems
and
UEENEEJ193A Analyse the thermodynamic performance of HVAC/R systems
or
UEENEEJ109A Verify functionality and compliance of refrigeration and air conditioning installations
UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace
UEENEEE102A Fabricate, assemble and dismantle utilities industry components
UEENEEE003B Solve problems in extra-low voltage single path circuits
UEENEEE105A Fix and secure electrotechnology equipment
UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications
UEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work
UEENEEJ102A Prepare and connect refrigerant tubing and fittings
UEENEEJ103A Establish the basic operating conditions of vapour compression systems
UEENEEJ104A Establish the basic operating conditions of air conditioning systems
UEENEEJ106A Install refrigerant pipe work, flow controls and accessories
UEENEEJ107A Install air conditioning and refrigeration systems, major components and associated equipment
UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerants
UEENEEJ110A Select refrigerant piping, accessories and associated controls
UEENEEJ111A Diagnose and rectify faults in air conditioning and refrigeration systems and components
UEENEEJ113A Commission air conditioning and refrigeration systems
UEENEEJ153A Find and rectify faults motors and associated controls in refrigeration and air conditioning systems
UEENEEJ170A Diagnose and rectify faults in air conditioning and refrigeration control systems
UEENEEJ194A Solve problems in low voltage refrigeration circuits
UEENEEP012A Disconnect / reconnect composite appliances connected to low voltage installation wiring
UEENEEP017A Locate and rectify faults in low voltage composite appliances using set procedures
UEENEEP024A Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply
UEENEEP025A Attach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supply