This unit involves the skills and knowledge required to verify functionality and compliance of electrical refrigeration/air conditioning appliances.

It includes testing and visually inspecting electrical refrigeration/air conditioning appliance to verifying that it is safe and complies with requirements. It also includes following procedures for conducting safety and functionality tests, conducting visual inspections, identifying non-compliance defects, documenting results and recommendations, and initiating the rectification of any defect.

To undertake this unit, the learner must have a Trainee Refrigerant Handling Licence as it includes work on refrigeration and air conditioning equipment that carries the risk of a fluorocarbon refrigerant being emitted.

The skills and knowledge described in this unit require a national Refrigerant Handling Licence as it includes work on refrigeration and air conditioning equipment that carries the risk of a fluorocarbon refrigerant being emitted while decanting the refrigerant or manufacturing, installing, commissioning, servicing, maintaining or decommissioning refrigeration and air conditioning equipment.

The skills and knowledge described in this unit require a licence or permit to practice in the workplace where work is carried out on electrical installations which are designed to operate at voltages greater than 50 V alternating current (a.c.) or 120 V direct current (d.c.).

Competency development activities in this unit are subject to regulations directly related to licensing. Where a licence or permit to practice is not held, skills and knowledge described in this unit require a relevant contract of training, such as an Australian Apprenticeship.

Additional and/or other conditions may apply in some jurisdictions subject to regulations related to refrigeration, air conditioning or electrical work. Practice in the workplace and during training is also subject to work health and safety (WHS)/occupational health and safety (OHS) regulations.

Permits may also be required for some work environments, such as confined spaces, working aloft, near live electrical apparatus and site rehabilitation.

You may want to include more information here about the target group and the purpose of the assessments (eg formative, summative, recognition)



Evidence Required

List the assessment methods to be used and the context and resources required for assessment. Copy and paste the relevant sections from the evidence guide below and then re-write these in plain English.

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions on at least two separate occasions and include:

applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures and practices, including using of risk control measures

applying sustainable energy principles and practices

dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment

verifying compliance and functionality of electrical refrigeration/air conditioning appliances, including:

acting within regulatory limits

conducting electrical tests safely and correctly

conducting refrigeration/air conditioning tests safely and correctly

identifying non-compliant defects from test results

identifying visual defects

recommending appropriate corrective actions

reporting electrical inspection and verifying findings.

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions and include knowledge of:

mandatory testing and verification requirements

refrigeration/air conditioning appliance efficiency

refrigeration/air conditioning appliance electrical testing techniques, including testing and compliance verification methods

relevant refrigeration/air conditioning appliance manufacturer specifications

relevant safe work method statements (SWMS)/job safety assessments or risk mitigation processes

relevant WHS/OHS legislated requirements

relevant workplace documentation

relevant workplace policies and procedures

visual inspection methods.

Assessors must hold credentials specified within the Standards for Registered Training Organisations current at the time of assessment.

Assessment must satisfy the Principles of Assessment and Rules of Evidence and all regulatory requirements included within the Standards for Registered Training Organisations current at the time of assessment.

Assessment must occur in workplace operational situations where it is appropriate to do so; where this is not appropriate, assessment must occur in simulated workplace operational situations that replicate workplace conditions.

Assessment processes and techniques must be appropriate to the language, literacy and numeracy requirements of the work being performed and the needs of the candidate.

Resources for assessment must include access to:

a range of relevant exercises, case studies and/or other simulations

relevant and appropriate materials, tools, equipment and personal protective equipment (PPE) currently used in industry

applicable documentation, including workplace procedures, equipment specifications, regulations, codes of practice and operation manuals.


Submission Requirements

List each assessment task's title, type (eg project, observation/demonstration, essay, assingnment, checklist) and due date here

Assessment task 1: [title]      Due date:

(add new lines for each of the assessment tasks)


Assessment Tasks

Copy and paste from the following data to produce each assessment task. Write these in plain English and spell out how, when and where the task is to be carried out, under what conditions, and what resources are needed. Include guidelines about how well the candidate has to perform a task for it to be judged satisfactory.

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEE Electrotechnology Training Package Companion Volume Implementation Guide.

Verifying functionality and compliance of air conditioner/refrigeration system appliances must include at least the following:

two types of appliances, including:

conducting visual inspection of appliances

conducting all electrical tests

conducting all refrigeration tests

Electrical testing must include at least the following:

isolation testing

insulation resistance of equipment

resistance of the internal circuits of equipment

polarity of supply and equipment

continuity of earthing

correct electrical connections load current

Refrigeration/air conditioning testing must include at least the following:

pressure test apparatus/circuits

leak test apparatus/circuits

evacuation test apparatus/circuits

compressor efficiency

controls tests

refrigerant charge

operating pressures

system operation system capacity

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions on at least two separate occasions and include:

applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures and practices, including using of risk control measures

applying sustainable energy principles and practices

dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment

verifying compliance and functionality of electrical refrigeration/air conditioning appliances, including:

acting within regulatory limits

conducting electrical tests safely and correctly

conducting refrigeration/air conditioning tests safely and correctly

identifying non-compliant defects from test results

identifying visual defects

recommending appropriate corrective actions

reporting electrical inspection and verifying findings.

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions and include knowledge of:

mandatory testing and verification requirements

refrigeration/air conditioning appliance efficiency

refrigeration/air conditioning appliance electrical testing techniques, including testing and compliance verification methods

relevant refrigeration/air conditioning appliance manufacturer specifications

relevant safe work method statements (SWMS)/job safety assessments or risk mitigation processes

relevant WHS/OHS legislated requirements

relevant workplace documentation

relevant workplace policies and procedures

visual inspection methods.

Assessors must hold credentials specified within the Standards for Registered Training Organisations current at the time of assessment.

Assessment must satisfy the Principles of Assessment and Rules of Evidence and all regulatory requirements included within the Standards for Registered Training Organisations current at the time of assessment.

Assessment must occur in workplace operational situations where it is appropriate to do so; where this is not appropriate, assessment must occur in simulated workplace operational situations that replicate workplace conditions.

Assessment processes and techniques must be appropriate to the language, literacy and numeracy requirements of the work being performed and the needs of the candidate.

Resources for assessment must include access to:

a range of relevant exercises, case studies and/or other simulations

relevant and appropriate materials, tools, equipment and personal protective equipment (PPE) currently used in industry

applicable documentation, including workplace procedures, equipment specifications, regulations, codes of practice and operation manuals.

Copy and paste from the following performance criteria to create an observation checklist for each task. When you have finished writing your assessment tool every one of these must have been addressed, preferably several times in a variety of contexts. To ensure this occurs download the assessment matrix for the unit; enter each assessment task as a column header and place check marks against each performance criteria that task addresses.

Observation Checklist

Tasks to be observed according to workplace/college/TAFE policy and procedures, relevant legislation and Codes of Practice Yes No Comments/feedback
WHS/OHS hazards, risk control methods, relevant standards, codes and legislation are obtained and applied 
 
 
 
 
 
Electrical appliances are checked and isolated in accordance with WHS/OHS requirements and workplace procedures 
 
 
 
 
Testing or measuring on live electrical appliance and operating system is conducted in accordance with WHS/OHS requirements and workplace procedures 
 
 
 
 
Appliance is cleaned and made safe in accordance with established procedures 
 
 
 

Forms

Assessment Cover Sheet

UEERA0093 - Verify functionality and compliance of appliances
Assessment task 1: [title]

Student name:

Student ID:

I declare that the assessment tasks submitted for this unit are my own work.

Student signature:

Result: Competent Not yet competent

Feedback to student

 

 

 

 

 

 

 

 

Assessor name:

Signature:

Date:


Assessment Record Sheet

UEERA0093 - Verify functionality and compliance of appliances

Student name:

Student ID:

Assessment task 1: [title] Result: Competent Not yet competent

(add lines for each task)

Feedback to student:

 

 

 

 

 

 

 

 

Overall assessment result: Competent Not yet competent

Assessor name:

Signature:

Date:

Student signature:

Date: