Assessor Resource

UEGNSG811
Monitor and operate complex flow control, measuring and regulating devices for gas distribution

Assessment tool

Version 1.0
Issue Date: May 2024


This unit involves the skills and knowledge required to monitor and operate complex flow control, measuring and regulating device to monitor and control gas supply in gas distribution system in accordance with relevant legislation, codes of practice, regulations and workplace procedures.

It includes on site local inspecting and controlling of gas flow and pressure; local monitoring of gas flow, pressure and measurement; recording and reporting on anomalies to gas flow pressure and measurement; and controlling the system to organisational and statutory requirements.

This unit applies to gas distribution systems, subject to all work health and safety (WHS)/occupational health and safety (OHS) and duty of care requirements being met for the workplace.

The application of the skills and knowledge described in this unit may require a license or permit to practice in the workplace.

Other conditions may apply under state and territory legislative and regulatory licencing requirements which must be confirmed prior to commencing this unit.

You may want to include more information here about the target group and the purpose of the assessments (eg formative, summative, recognition)

Submission Requirements

List each assessment task's title, type (eg project, observation/demonstration, essay, assingnment, checklist) and due date here

Assessment task 1: [title]      Due date:

(add new lines for each of the assessment tasks)


Assessment Tasks

Copy and paste from the following data to produce each assessment task. Write these in plain English and spell out how, when and where the task is to be carried out, under what conditions, and what resources are needed. Include guidelines about how well the candidate has to perform a task for it to be judged satisfactory.

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEG Gas Industry Training Package Companion Volume Implementation Guide.

competency must demonstrate monitoring and operating of complex gas flow control, measuring and regulating devices for gas pressure and flow control with the following:

custody transfer stations

inlets and city gates

scraper stations

gas storage facilities

main line valves

constants and variables must include the following:

inspecting and controlling

regulation of flow and pressure

measuring

recording and reporting

regulation of flow and regulation devices

regulation of the system

equipment

organisational and statutory requirements

equipment must include at least two (2) of the following procedures:

pressure controllers - operation and maintenance commissioning/setting

troubleshooting

pressure boosters minor repairs

types/models

basic regulators must include at least two (2) of the following:

sleeve types

diaphragm types

hydraulic plug types

distribution valves must include the following:

ball, plug, gate instrument and butterfly valves

meters must include at least two (2) of the following:

meters diaphragm meters

rotary meters

turbine meters

oil changing

operational checks must include at least three (3) of the following:

single run units

dual run units

district regulators

field regulators

pressure alterations must include the following:

industrial units

regulator stations

distribution mains

flaring and purging must include the following:

industrial units

regulator stations

distribution mains

overpressure protection systems - function and operation must include at least three (3) of the following:

over-pressure shut-off (OPSO)

internal pressure relief systems

pressure relief valves

slam shut systems

valve actuator & control systems

documentation must include the following:

risk assessments

timesheets

completing worksheets

notifications and work permits

equipment checklists

meter bypass forms

service orders

pressure recording charts

regulator station heaters must include the following:

heater: scheduled maintenance procedures

heater: operational checks

water quality testing

Copy and paste from the following performance criteria to create an observation checklist for each task. When you have finished writing your assessment tool every one of these must have been addressed, preferably several times in a variety of contexts. To ensure this occurs download the assessment matrix for the unit; enter each assessment task as a column header and place check marks against each performance criteria that task addresses.

Observation Checklist

Tasks to be observed according to workplace/college/TAFE policy and procedures, relevant legislation and Codes of Practice Yes No Comments/feedback
Work requirements for monitoring and operating complex gas flow control, measuring and regulating device are interpreted from plans, specifications and job instructions 
 
 
 
 
 
 
 
 
Gas flow device and equipment performance information is collected and reported in accordance with workplace and job requirements 
 
 
 
 
 
 
Flow regulating systems are inspected and adjustments made to meet gas flow demand and customer requirements 
 
 
 
 

Forms

Assessment Cover Sheet

UEGNSG811 - Monitor and operate complex flow control, measuring and regulating devices for gas distribution
Assessment task 1: [title]

Student name:

Student ID:

I declare that the assessment tasks submitted for this unit are my own work.

Student signature:

Result: Competent Not yet competent

Feedback to student

 

 

 

 

 

 

 

 

Assessor name:

Signature:

Date:


Assessment Record Sheet

UEGNSG811 - Monitor and operate complex flow control, measuring and regulating devices for gas distribution

Student name:

Student ID:

Assessment task 1: [title] Result: Competent Not yet competent

(add lines for each task)

Feedback to student:

 

 

 

 

 

 

 

 

Overall assessment result: Competent Not yet competent

Assessor name:

Signature:

Date:

Student signature:

Date: