Google Links

Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge

Elements and Performance Criteria

  1. Research requirements of applicable legislation.
  2. Research requirements of applicable codes and standards.
  3. Analyse compliance requirements.

Range Statement

This section specifies work environments and conditions that may affect performance. Essential operating conditions that may be present (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) are included. Bold italicised wording, if used in the performance criteria, is detailed below.

Legislation must include:

legislation and regulations relating to:

building

conservation

construction materials and methods

energy

environment

heritage

work health and safety (WHS)

planning

water

local authority planning schemes

industry-specific requirements relating to building use.

Project locations must include:

jurisdictions of two or more different:

countries

local authorities

States and Territories

areas with these two specific conditions:

bushfire threat zone

cyclone zone

one or more of the following:

coastal area

flood zone

mountainous area

rural area

snow zone.

Conditions must include:

natural waterways

protected flora and fauna.

Codes and standards must include:

Australian standards

National Construction Code (NCC)

codes and standards applicable:

at project locations

in particular conditions.


Performance Evidence

A person demonstrating competency in this unit must satisfy the requirements of the elements, performance criteria, foundation skills and range of conditions of this unit.

The person must also develop a body of current research findings suitable for application to three projects (except construction Type A buildings), each of a maximum area of 2000 square metres and involving different classes of commercial and industrial buildings as defined in the Building Code of Australia (BCA) section of the National Construction Code (NCC), consisting of:

one project incorporating Classes 2, 5, 6 and 7a

one project incorporating Class 3 or 9c (aged care facility)

one project incorporating Classes 7b and 8

Each of the above projects must be in a different climatic, geographic or planning zone.

In doing the above, the person must:

analyse compliance requirements in relation to the three different types of projects, different locations and conditions

systematically document and store research findings

communicate with clients regarding compliance conflicts and constraints affecting design preferences, including proposing innovative solutions.


Knowledge Evidence

A person demonstrating competency in this unit must demonstrate knowledge of:

building designers’ duty of care to ensure quality and safety of designs

compliance requirements relating to small-scale commercial and industrial building design projects, including:

Australian standards

NCC requirements

environmental and sustainability requirements, including:

energy efficiency

fire resistance, including resistance to bushfire attack

legislative requirements

regulatory limitations

organisational scope of business and client demographics, including:

geographic areas of operation

trends in clients’ design preferences

types of building design projects that form the core business of the organisation

sources of reliable information on compliance requirements.