Google Links

Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge

Elements and Performance Criteria

  1. Set up and prepare to work with live fibre
  2. Connect splitter input fibre to feeder cable
  3. Perform live WDM commission testing of ODN installation used in FTTx network
  4. Complete installation process

Range Statement

Specifies different work environments and conditions that may affect performance. Essential operating conditions that may be present (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) areincluded. It is restricted to essential operating conditions and any other variables essential to the work environment.

Operating wavelengths must include:

1310 nm

1490 nm

1550 nm.

Range of acceptable power levels must include:

-20 to + 2 dBm @ 1310 nm

-26 to -6 dBm @ 1490 nm

-11.5 to +5 dBm @ 1550 nm.

Maximum and minimum power losses must include:

23.3 dB to 15.0 dB @1310 nm

21.6 dB to 8.0 dB @1490 nm

20.9 dB to 9.5 dB @1550 nm.

Acceptance tests must include:

delay

dispersion

optical attenuation and loss measurements

optical power levels

phase.