Google Links

Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge

Elements and Performance Criteria

  1. Remove aircraft electrical hardware
  2. Install aircraft electrical hardware

Required Skills

Required skills

Look for evidence that confirms skills in

the preparation and termination of electrical cables to aircraft industry standards using crimping techniques soldering techniques and solder sleeves joints

the correct interpretation of aircraft wire markings terminal block identification and plugsocket pin numbering systems

inspection of electrical looms and harness pre and post removal and installation to ensure minimum bends are maintained cable is not in tension plugs are correctly aligned security of route ensures no chaffing of insulation adequate clipping and cable ties have been utilised and construction complies with aircraft industry standards

positive identification of miscellaneous electrical hardware andor components in all aircraft systems

Required knowledge

Look for evidence that confirms knowledge of

component attachment methods

connection of hardware and plugs

application of relevant OHS practices

the use of approved maintenance documentation and aircraft publications relating to miscellaneous aircraft electrical hardware and components

electrical wiring used in aircraft and wire marking

plugsocket pin numbering and terminal block identification

cable and loom installation requirements

crimping tools and crimp terminals

soldering techniques and the use of solder sleeve joints

electrical fundamentals and related mathematical and physics principles

Evidence Required

The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria required skills and knowledge range statement and the Assessment Guidelines for the Training Package

Overview of assessment

A person who demonstrates competency in this unit must be able to apply hand skills use specialist tools and use maintenance publications to remove and install miscellaneous items of aircraft electrical hardwarecomponents while observing all relevant safety precautions

Critical aspects for assessment and evidence required to demonstrate competency in this unit

It is essential that applicable cleanliness requirements and OHS safety precautions are fully observed including awareness of electrostatic discharge procedures

Evidence of transferability of skills and knowledge related to removal and installation is essential An understanding of the attachment methods connection of hardware and system operation as they relate to the work must be demonstrated before undertaking any action The work plan should take account of applicable safety and quality requirements in accordance with the industry and regulatory standards

A person cannot be assessed as competent until it can be demonstrated to the satisfaction of the workplace assessor that the relevant elements of the unit of competency are being achieved under routine supervision on each of the connection methods and listed in the Range Statement This shall be established via the records in the Log of Industrial Experience and Achievement or where appropriate an equivalent Industry

Context of and specific resources for assessment

Competency should be assessed in the workplace or simulated workplace using tools and equipment specified in maintenance manuals It is also expected that generalpurpose tools test and ground support equipment found in most routine situations would be used where appropriate

Method of assessment

Guidance information for assessment


Range Statement

The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.

Note

Range statements listed below are numbered to facilitate specification of the assessment requirements included in the Evidence Guide

Hardware connection methods

Removal and installation of electrical hardware involves one or more of the following connection methods:

1. Bolted

2. Soldered

3. Plug connectors

Types of electrical hardware

Electrical hardware includes:

switches, relays, lamps, terminal blocks, current limiters, circuit breakers, fuses, sockets, potentiometers, capacitors, inductors, magnetic amplifiers, transformers, rheostats, resistors and diodes, miscellaneous sensors and minor components hard mounted throughout the aircraft, busbars, lugs, ferrules, splices, connectors and electrical, electronic cables and looms

Basic soldering and crimping

The work will include the application of basic soldering and crimping skills associated with removal and installation of electrical hardware

Application of this unit may relate to:

scheduled or unscheduled maintenance activities

individual or team-related activities

Procedures and requirements

Refer to industry standard procedures specified by manufacturers, regulatory authorities or the enterprise