Google Links

Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge

Elements and Performance Criteria

  1. Prepare inspection areas for eddy current testing
  2. Perform eddy current testing
  3. Interpret and report the results of eddy current tests

Required Skills

Required skills

Look for evidence that confirms skills in

interpreting and following procedures

identifying inspection areas

identifying discontinuities and defects

selecting appropriate testing techniques and procedures

reading interpreting and applying relative testing standards

reading interpreting and applying relative conformance standards

using calculations relating to eddy current testing

assessing risk

entering routine and familiar information onto proformas and standard workplace forms

Required knowledge

Look for evidence that confirms knowledge of

cleaning and preparation processes

procedures and OHampS requirements in relation to the preparation process

established assessment procedures and techniques

types of discontinuities and their consequences

procedure for carrying out eddy current testing

tools equipment techniques and system verification checks necessary to carry out eddy current testing

basic principles of electricity magnetism electromagnetism and eddy current testing

Reactance field made by eddy current

Biot and Savant law Definition Practical right hand rules

Amperes law Definition Applications toroid infinite coil flat coil

Lenz law Definition Autoinduction factor Mutual induction factor Coupling factor

induced currents short circuit coil metallic mass skin effect reactance

cylindrical bars

theory of eddy currents

tubes

geometric defect characterisation

multiple defects

characteristics of eddy current probes

eddy current equipment

transmission

reception

data presentation

equipment controls

types of equipment

physical properties of materials

electrical conductivity

magnetic permeability

applications of eddy curry testing

influence of various parameters on eddy current measurement

defect position and orientation

compensation

structure and geometry of test part

coupling influence

relative speed

limitations of eddy current testing

hazards and safety precautions associated with eddy current testing

basic maintenance and storage procedures for testing equipment

common basic defects

methodsprocedures for reporting test results

any applicable industry standards nationalAustralian standards NOHSC guides StateTerritory regulatory codes of practicestandards

use and application of personal protective equipment

safe work practices and procedures

Evidence Required

The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria required skills and knowledge range statement and the Assessment Guidelines for the Training Package

Overview of assessment

A person who demonstrates competency in this unit must be able to perform eddy current testing Competency in this unit cannot be claimed until all prerequisites have been satisfied

Critical aspects for assessment and evidence required to demonstrate competency in this unit

Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria including required knowledge and be capable of applying the competency in new and different situations and contexts

Context of and specific resources for assessment

This unit may be assessed on the job off the job or a combination of both on and off the job Where assessment occurs off the job that is the candidate is not in productive work then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team The assessment environment should not disadvantage the candidate

This unit could be assessed in conjunction with any other units addressing the safety quality communication materials handling recording and reporting associated with performing eddy current testing in a range of industrial applications or other units requiring the exercise of the skills and knowledge covered by this unit

Method of assessment

Assessors should gather a range of evidence that is valid sufficient current and authentic Evidence can be gathered through a variety of ways including direct observation supervisors reports project work samples and questioning Questioning techniques should not require language literacy and numeracy skills beyond those required in this unit of competency The candidate must have access to all tools equipment materials and documentation required The candidate must be permitted to refer to any relevant workplace procedures product and manufacturing specifications codes standards manuals and reference materials

Guidance information for assessment


Range Statement

The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.

Preparation processes

Surface cleaning and drying

Obvious discontinuities

Observed changes in material homogeneity

Defects

Corrosion, metal fatigue, deformation in non-ferrous/ferrous alloys steels, fatigue cracks, stress corrosion cracking, heat damage, metal properties sorting, manufacturing defects, coating thickness measurement etc.