Google Links

Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge

Elements and Performance Criteria

  1. Plan installation and maintenance
  2. Works order is analysed and confirmed as required by site inspection
  3. Resources required for the job are identified and scheduled in accordance with operational procedures
  4. Hazards are identified, risks are assessed and control measures are implemented
  5. Switch equipment and transformer are transported to worksite
  6. Liaison and communication issues are resolved in accordance with organisational negotiation procedures
  7. Prepare the worksite
  8. Work plan and resources required are confirmed/checked at worksite
  9. Personnel participating in the activity, including plant operators and contractors, are fully briefed
  10. Road signs, barriers and warning devices are positioned to ensure a safe worksite
  11. Safeworking practices are observed on or about the running track/line
  12. Worksite is laid out in accordance with work plan to ensure minimum waste and rework
  13. Systems/circuits are isolated as required, proved safe to work on in accordance with works order, and electrical permits are received/accepted/returned as required
  14. Install switches and transformers
  15. Switch equipment, transformers and earthing systems are installed and connected
  16. Transformer is tested and voltage output is adjusted
  17. Visual inspection is carried out to confirm equipment/apparatus is in a safe condition to test and/or commission
  18. Commission is carried out in accordance with works order/plan
  19. Maintain switches and transformers
  20. Maintenance requirement is confirmed by detailed site diagnosis
  21. Maintenance, including removal, repair, replacement and reinstatement, is carried out in accordance with works order and the condition of equipment
  22. Complete work
  23. Worksite is rehabilitated
  24. Appropriate authority is notified on completion of work
  25. Records and documentation for updating system data are completed and processed

Performance Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria on at least one occasion and include:

applying appropriate repair/testing practices and procedures

applying relevant workplace procedures

communicating effectively with others

communicating plans, intentions and safety criteria to others

implementing contingency plans

interpreting and following operational instructions and prioritising work

modifying activities depending on operational contingencies, risk situations and environments

monitoring work activities in terms of planned schedule

operating and adapting to differences in equipment in accordance with operating procedures

performing calculations required for installation procedures

reading and interpreting relevant instructions, procedures, information, technical data, manuals and drawings

reporting and/or rectifying identified problems, faults or malfunctions, in accordance with regulatory requirements and workplace procedures

selecting and using test equipment and testing techniques

working collaboratively with others

working systematically with required attention to detail without injury to self or others, or damage to goods or equipment.


Knowledge Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria and include knowledge of:

applicable state/territory legislated rail safety requirements, relevant codes of practice, rail industry standards and/or guidelines

characteristics, capabilities and uses of types of pole mounted switches and transformers

distribution system earthing procedures as they relate to installing and maintaining electrical switches and transformer equipment

hazards that may exist when installing and maintaining pole mounted switches and transformers

live/energised line working techniques and equipment

problems that may occur when installing and maintaining pole mounted switches and transformers

relevant electrical/electronic theory and principles

relevant work health and safety (WHS)/occupational health and safety (OHS) and environmental procedures and regulations

relevant organisation and commercial publications, including construction manuals and technical instructions as they relate to installing and maintaining electrical equipment

relevant recording and documentation procedures

relevant sections of railway safety management plans, rail industry standards and the Australian/New Zealand Standard for Wiring Rules

relevant technical regulatory requirements

statutory/organisation traffic control requirements, work zone regulations and guidance signals for planned operations

switching or de-energising procedures and maintenance operations

visual inspection workplace procedures

workplace procedures for installing and maintaining pole mounted switches and transformers.