Elements and Performance Criteria
- Set up locomotive for portable remote operation
- Locomotive is set up for portable remote control operation in accordance with manufacturer instructions and/or organisational procedures
- Portable remote control equipment is installed as required in accordance with manufacturer instructions and/or organisational procedures
- Hazards are identified, risks are assessed and risk control measures are implemented
- Remote control system is tested and operation is confirmed in accordance with manufacturer instructions and/or organisational procedures
- Relevant work health and safety (WHS)/occupational health and safety (OHS) requirements are followed to prevent injury and damage to equipment
- Operate locomotive using portable remote control equipment
- Warning signage is placed as required in accordance with organisational procedures
- Portable remote control equipment is operated and monitored in accordance with operational requirements during train movements to provide safe train handling and control within defined limits
- Portable remote control equipment is operated with an awareness that not all people in work area vicinity may know locomotive is being operated remotely
- Operational difficulties encountered are addressed by reestablishing control of locomotive with minimum risk to personnel and equipment
- Shut down portable remote control equipment
- Locomotive is secured against unintentional movement in a safe location in accordance with organisational procedures
- Portable remote control equipment is shut down in accordance with manufacturer instructions and/or organisational policies and procedures
- Portable remote control equipment is removed from locomotive as required in accordance with manufacturer instructions and/or organisational policies and procedures
- Relevant WHS/OHS requirements are followed to prevent injury and damage to equipment