Google Links

Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge

Elements and Performance Criteria

  1. Prepare to conduct compliance inspection
  2. WHS/OHS risk control measures and procedures in preparation for the work are followed
  3. WHS/OHS hazards not previously identified are noted and risk control measures are implemented in consultation with appropriate person/s
  4. Installation documentation and/or relevant industry standard for the installation is reviewed and applied
  5. Appropriate person/s is consulted to ensure the work is coordinated effectively with others
  6. Tools, equipment and testing devices to verify compliance are obtained in accordance with workplace procedures and checked for operation and safety
  7. Conduct compliance inspection
  8. Need to inspect, test and measure live electrical work is determined in accordance with WHS/OHS requirements and workplace procedures
  9. Circuits/machines/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
  10. Inspection of the mains and main switchboard is conducted for compliance of protection metering earthing circuit arrangements and markings in accordance with relevant industry standard
  11. Inspection of circuits is conducted for compliance of the installed wiring accessories switchgear/control gear and current-using devices in accordance with relevant industry standard
  12. Electrical equipment complies with relevant safety requirements and industry standards and is obtained from appropriate person/s
  13. Inspection is conducted to verify compliance of earthing insulation polarity circuit connections and operation of residual current devices (RCDs) in accordance with relevant industry standards
  14. Fault-loop impedance is determined as being sufficiently low by testing calculation and compliance with arrangement of the installation in accordance with relevant industry standards
  15. Unplanned events are responded to in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
  16. Act and report on inspection findings
  17. Non-compliance defects are identified and documented in accordance with relevant industry standards and workplace procedures
  18. Actions are taken for non-compliance defects within the scope of inspection responsibilities in accordance with workplace procedures and relevant industry standards
  19. Inspection report is completed and issued to appropriate person/s in accordance with workplace procedures and relevant industry standards

Range Statement

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEE Electrotechnology Training Package Companion Volume Implementation Guide.

Conducting compliance inspection must include at least three types of installations from the following:

caravan parks

construction and demolition sites

marinas

medical treatment areas

moveable premises

Electrical installations must include at least the following:

consumer mains

earthing system and distribution boards

final sub-circuits and requirement to the installation type

main earthing system and main switchboard and sub-mains


Performance Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions on at least one occasion and include:

obtaining appropriate documentation and equipment in preparation for the inspection

conducting detailed inspections and testing methodically

identifying non-compliance defects

relating non-compliance defects with appropriate clause in regulatory standards

acting within the inspection authority when dealing with non-compliance defects

documenting and reporting inspection findings

dealing with unplanned events

applying scope of inspection responsibilities

completing inspection

applying relevant industry standards, codes of practice and regulations

applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including using risk control measures

following workplace procedures

preparing and conducting compliance inspection, including:

inspecting mains, circuits, electrical equipment on at least three types of installations from the following:

caravan parks

construction and demolition sites

marinas

medical treatment areas

moveable premises

obtaining and using tools, equipment and testing devices

performing calculations.


Knowledge Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions and include knowledge of:

compliance inspections of low voltage (LV) special electrical installations, including:

technical standards, regulations and codes for special electrical installations encompassing:

additional requirements for special installations

caravan parks

construction and demolition sites

marinas

medical treatment areas

moveable premises

high voltage (HV) installation in consumer’s premises

problem-solving techniques

procedures for dealing with non-compliance defects

processes for inspection of main switchboard and earthing

relevant manufacturer specifications

relevant job safety assessments or risk mitigation processes

relevant tool, equipment and testing devices

relevant WHS/OHS legislated requirements

relevant workplace documentation

relevant workplace policies and procedures.