Google Links

Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge

Elements and Performance Criteria

  1. Prepare to inspect and test an electrical installation
  2. WHS/OHS risk control measures and procedures in preparation for the work are followed
  3. WHS/OHS hazards not previously identified are noted, risks assessed and risk control measures implemented
  4. Installation documentation and relevant industry standard are reviewed and applied
  5. Appropriate person/s is consulted to ensure the work is coordinated effectively with others
  6. Tools, equipment and testing devices needed to verify compliance are obtained in accordance with workplace procedures and checked for operation and safety
  7. Preparatory work is checked to ensure no damage has occurred in accordance with workplace procedures
  8. Visually inspect the installation
  9. Need to inspect, test and measure live work is determined in accordance with WHS/OHS requirements and workplace procedures
  10. Circuits/machines/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
  11. Installed wiring is checked for suitability for the environments and protected from damage and overheating
  12. Cable conductor sizes acquired are inspected to meet current-carrying capacity requirements, voltage-drop and fault-loop impedance limitations in accordance with relevant industry standards
  13. Inspection protection methods and devices are validated to meet coordination requirements for overload and short circuit protection in accordance with relevant industry standards
  14. Switchgear and control gear are inspected, validated and appropriately rated to meet functional requirements in accordance with relevant industry standards
  15. Electrical equipment is checked for compliance with safety requirements in accordance with relevant industry standards
  16. Earthing system components are checked, located and conductors correctly sized in accordance with relevant industry standards
  17. Markings on switchboards are checked for accuracy and clarity in accordance with relevant industry standards
  18. Conduct safety testing
  19. Need to test and measure live electrical work is conducted in accordance with WHS/OHS requirements and workplace procedures
  20. Mandatory tests are conducted to verify earthing conductor resistance is sufficiently low; insulation resistance is sufficiently high; polarities are correct; circuit connections are correct; and tests are in accordance with relevant industry standards
  21. Inspection and testing are conducted to verify fault-loop impedance is sufficiently low and residual current device (RCD) operates as intended in accordance with job requirements and relevant industry standards
  22. Report inspection and test findings
  23. Worksite is cleaned and made safe in accordance with workplace procedures
  24. Non-compliance defects are identified and reported in accordance with workplace procedures
  25. Recommendations for rectifying defects are made in accordance with workplace procedures
  26. Mandatory documentation is completed in accordance with workplace procedures

Performance Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions on at least one occasion and include:

selecting correct tools and testing equipment

identifying visual non-compliance defects

using effective methods for conducting mandatory and optional tests

identifying non-compliance from test results

identifying causes of non-compliance

completing mandatory reporting

dealing with unplanned events

applying relevant work health and safety (WHS)/occupational health and safety (OHS requirements, including using risk control measures

preparing, inspecting and testing an electrical installation

reporting inspection and test findings

reviewing relevant industry documentation.


Knowledge Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions and include knowledge of:

electrical installations, testing, compliance and functionality verification of special electrical installations, including:

technical standards, regulations and codes for special electrical installations encompassing:

additional requirements for special installations

caravan parks

construction and demolition sites

marinas

medical treatment areas

moveable premises

high voltage (HV) installation in consumer’s premises

mandatory and optional testing and verification requirements applicable to special installations encompassing:

testing techniques

features of special installations that can be visually inspected

caravan parks

construction and demolition sites

marinas

medical treatment areas

moveable premises

HV installation in consumer’s premises

relevant industry standards

relevant job safety assessments or risk mitigation processes

relevant WHS/OHS legislated requirements

relevant workplace documentation

relevant workplace policies and procedures.