Google Links

Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge

Elements and Performance Criteria

  1. Prepare to diagnose and rectify faults
  2. Details of the air conditioningor refrigerationsystem faultare obtained from documentation, clientand/or from supervisor to establish scope of work to be completed
  3. Advice is sought from supervisor, as required, to ensure work is coordinated with others
  4. Sources of materials required for work are accessed in accordance with workplace procedures
  5. Tools, equipment and testing devices are obtained in accordance with workplace procedures and checked for operational safety
  6. Circuits/machines and/plant are checked as being isolated, where necessary, in accordance with workplace procedures and WHS/OHS requirements
  7. Fault finding, using measured and calculated values of system and component parameters, is undertaken methodically in accordance with workplace procedures
  8. Faults, beyond the scope of refrigeration and air conditioning system work, are identified and reported in accordance with workplace procedures
  9. Control system components are dismantled, where necessary, and parts safely stored to protect them against loss or damage in accordance with workplace procedures
  10. Faulty components are rechecked and fault status is confirmed
  11. Unexpected situations are resolved in accordance with workplace procedures, safety guidelines and with the approval of an authorised person/supervisor
  12. Fault-finding activities are completed without damage to apparatus, circuits, the surrounding environment and/or services using relevant sustainable energy practices in accordance with workplace procedures
  13. Equipment is checked as being isolated, where necessary, in accordance with workplace procedures and WHS/OHS requirements
  14. Materials required are obtained in accordance with workplace procedures
  15. Repairs are completed without damage to other components or apparatus using sustainable energy principles in accordance with workplace procedures
  16. Effectiveness of repair work is tested in accordance with workplace procedures
  17. Air conditioning and refrigeration control system is reassembled, given a final test and prepared for return to service in accordance with workplace procedures
  18. Complete and report fault-finding and rectification activities
  19. Report is completed in accordance with workplace procedures

Range Statement

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEE Electrotechnology Training Package Companion Volume Implementation Guide.

Diagnosing and rectifying faults in air conditioning and refrigeration control systems must include at least the following:

two refrigeration and/or air conditioning control system

four faults:

open circuit

short circuit

incorrect connections

insulation failure

unsafe condition

control apparatus/component failure

related mechanical failure


Performance Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions on at least two separate occasions and include:

applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including:

applying safe working practices

using risk control measures

completing and reporting fault-finding and rectification activities

diagnosing and rectifying faults in refrigeration and air conditioning control systems, including:

dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment

finding at least four faults

providing report for rectifications undertaken

rectifying faults without damage

using approved methodical fault-finding techniques

implementing legislation, industry standards, codes of practice and regulations

using manufacturer specifications and manuals.


Knowledge Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions and include knowledge of:

diagnose and rectify faults in refrigeration and air conditioning control systems, including:

control systems and components

method and procedures of finding, rectifying and recording control system faults

refrigeration and air conditioning direct digital control applications and basic operation

refrigeration and air conditioning electrical/electronic control types, applications, operation, installation/replacement, setting, adjustment and testing

refrigeration and air conditioning pneumatic control applications and basic operation

refrigeration and air conditioning process characteristics and control parameters

system responses to parameter changes

refrigeration and air conditioning direct digital control applications and basic operation

relevant legislation, industry standards, codes of practice and regulations

relevant manufacturer specifications

relevant risk mitigation processes, including:

potential hazards

risk control measures

safe working practices

relevant WHS/OHS legislated requirements

relevant workplace documentation

relevant workplace policies and procedures

WiFi/router controls for variable air volume (VAV) and remote access controls for refrigeration and air conditioning.