Elements and Performance Criteria
- Prepare to recover refrigerants, pressure and leak test, evacuate and charge refrigeration appliance
- Safety hazards which have not previously been identified are noted and risk control measures implemented in accordance with workplace procedures
- Extent of work to be completed is determined from documentation and/or discussion with supervisor/appropriate person/s in accordance with workplace procedures
- Work is sequenced in accordance with job schedule and workplace procedures
- Appropriate person/s is consulted, as required, to ensure work is coordinated with others
- Refrigerants, lubricants and cleaning materials are obtained in accordance with workplace procedures
- Tools, equipment and testing devices are obtained in accordance with workplace procedures and checked for operational safety
- Recover refrigerants, pressure and leak test, evacuate and charge refrigeration appliance
- Circuits, machines and plant are checked as being isolated, where necessary, in accordance with workplace procedures and WHS/OHS requirements
- Refrigerant is removed from appliance safely and is placed into labelled containers in accordance with workplace procedures and regulatory requirements
- Precautions are taken in accordance with workplace procedures to prevent damage to components while pressure testing appliance
- Pressure testing is conducted in accordance with workplace procedures using dry nitrogen at a pressure relative to refrigerant used
- Leaks are located and rectified using testing methods appropriate to the appliance under test in accordance with workplace procedures
- Appliance is evacuated to required level and is cleaned of all moisture and other contaminates in accordance with workplace procedures
- A 'drop test' is used to test effectiveness of evacuation in accordance with workplace procedures using an appropriate electronic vacuum gauge
- Components and lubricants are checked and maintained in accordance with workplace procedures and manufacturer specifications
- Appliance is charged with appropriate refrigerant in accordance with workplace procedures and manufacturer specifications
- Problematic situations are resolved in accordance with workplace procedures and are referred to a supervisor
- Appliance is pressure and leak tested, evacuated and charged without waste of materials or damage to apparatus, the surrounding environment and/or services using relevant sustainable energy practices in accordance with workplace procedures
- Complete and report on refrigerants recovery pressure and leak test and evacuate and charge work
- Contaminated refrigerant is dealt with in accordance with workplace procedures and legislative/regulatory requirements
- Completion of work is documented and an appropriate person/supervisor is notified in accordance with workplace procedures