Google Links

Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge

Elements and Performance Criteria

  1. Prepare to selectrefrigerant piping, accessories and associated controls
  2. WHS/OHS and regulatory requirements of the refrigeration system are identified, obtained and applied
  3. Develop refrigerant pipe work arrangements
  4. Pipe work arrangements are developed to ensure safe and functional operation of the refrigerant system in accordance with workplace procedures
  5. Pipe work is arranged to comply with technical industry standards, job specifications and requirements
  6. Select refrigerant piping, accessories and associated controls
  7. Pipe and tubing are sized to meet refrigeration parameters and capacity requirements for the refrigerant to be used
  8. Pipe and tubing quantities are determined from equipment location diagrams and job specifications
  9. Refrigeration controls and accessories are selected to meet load requirements based on calculated or deemed-to-comply solutions
  10. Control devices are selected to meet functional and regulatory requirements
  11. Electrical control devices are selected to meet current voltage and ingress protection ratings in accordance with industry standards
  12. Evidence is obtained to confirm the selected refrigeration equipment and control devices comply with job requirements and industry standards
  13. Document refrigerant piping, accessories and associated controls selection
  14. Refrigeration installation arrangement and specifications for selected items are documented in accordance with workplace procedures and forwarded to appropriate person/s

Range Statement

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEE Electrotechnology Training Package Companion Volume Implementation Guide.

Selecting refrigerant pipe/tube, accessories and associated controls must include at least two different refrigeration systems and include the following:

pipe sizes determined using recommended manufacturers specifications and the total equivalent length calculation methods refrigeration flow controls

isolation/access valves

filter-dryers

sight glasses

accessories

thermostats

pressure controls

humidity controls


Performance Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions on at least two separate occasions and include:

applying environmental and sustainable principles and practices

applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures and practices, including:

using personal protective equipment (PPE)

using risk control measures

arranging pipe work to comply with regulatory and functional requirements

completing relevant documentation

dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment

documenting pipe work arrangements, specifications for items selected and reasons for selections made

preparing and selecting refrigerant piping, accessories and controls for refrigeration and air conditioning installations in accordance with system load and regulatory requirements, industry standards and workplace procedures, including:

planning the refrigerant pipe work route and arrangement in accordance with job specifications

reading and interpreting drawings and requirements related to the installation

selecting appropriate type, size and quantity of piping and tubing

selecting control devices that meet functional requirements

selecting refrigeration accessories that meets load requirements.


Knowledge Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions and include knowledge of:

refrigerant liquid and vapour flow control selection, including expansion valves, solenoids and pressure regulators

refrigerant piping layout and routing

refrigerant piping sizing and accessories selection for suction, discharge and liquid lines

refrigeration and air conditioning controls and capacity control selection, including pressure controls and thermostats

relevant environmental and sustainable principles and practices, including:

environment protection

sustainable energy

sustainable resources

relevant drawings and specifications, including:

control diagrams

equipment installation requirements

equipment layouts and drawings

equipment manufacturer specifications and symbols

job specifications

piping diagrams

site drawings

wiring diagrams

relevant equipment, including software applications

relevant industry standards, codes of practice and regulations

relevant manufacturer instructions

relevant problem-solving techniques

relevant refrigerant piping, accessories and controls for refrigeration and air conditioning installations

relevant safe work method statements (SWMS)/job safety assessments or risk mitigation processes

relevant WHS/OHS legislated requirements

relevant workplace documentation

relevant workplace policies and procedures.