Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge

Elements and Performance Criteria

  1. Prepare to service room air conditioner
  2. Extent of air conditioner work to be undertaken is determined from service/fault request and/or discussions with appropriate person/s
  3. Advice is sought from work supervisor to ensure servicing work is coordinated effectively with others
  4. Sources of materials/parts required for the servicing work are determined in accordance with workplace procedures
  5. Tools, equipment and testing devices needed to locate faults are obtained in accordance with workplace procedures and checked for correct operation and safety
  6. Service room air conditioner
  7. Air conditioner appliance is inspected, checked and isolated in accordance with WHS/OHS requirements and workplace procedures
  8. Safety hazards resulting from air conditioner defect or fault are documented and risk control measures devised and implemented in consultation with appropriate person/s
  9. Air conditioner appliances are tested for efficient operation and components affecting efficiency are inspected for wear or defects in accordance with industry standards, manufacturer service manuals and industry codes of practice
  10. Air conditioner appliance faults and their cause are determined through the application of refrigerated appliances and using measured and calculated values of appliance parameters
  11. Air conditioner appliance is dismantled, as required, and parts stored to protect against loss or damage
  12. Defective worn or faulty air conditioner appliance components are rechecked and their status confirmed
  13. Replacement parts required to rectify defects/faults are sourced and obtained in accordance with workplace procedures
  14. Effectiveness of the repair is inspected and tested in accordance with workplace procedures
  15. Air conditioner apparatus is reassembled, tested and prepared for return to service
  16. Unplanned situations are dealt with safely in accordance with workplace procedures and with the approval of authorised person/s in a manner that minimises risk to personnel and equipment
  17. Servicing activities are carried out without damage to apparatus, circuits, the surrounding environment or services using sustainable energy practices
  18. Complete and report fault-finding and repair activities
  19. Service report is completed and verified by appropriate person/s in accordance with workplace procedures

Range Statement

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEE Electrotechnology Training Package Companion Volume Implementation Guide.

Servicing self-contained room air conditioners must include at least the following:

two types of room air conditioners

four of the following defects/faults:

higher energy use than previously experienced

not cooling/heating enough

fan not operating

appliance noisy

electric shock received from appliance cabinet


Performance Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions on at least two separate occasions and include:

applying relevant work health and safety (WHS)/occupational health and safety (WHS/OHS) requirements and workplace procedures and practices, including using risk control measures

applying sustainable energy principles and practices

completing service report accurately

dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment

determining the nature of the work from service request

finding faults efficiently

identifying defective components affecting appliance efficiency

rectifying defects/faults effectively

servicing room air conditioners

testing appliance functions effectively.


Knowledge Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions and include knowledge of:

component repair/replacement methods

relevant job safety assessments or risk mitigation processes

relevant manufacturer specifications, including parts catalogues and service reports

relevant WHS/OHS legislated requirements

relevant workplace documentation

relevant workplace policies and procedures

self-contained room air conditioners, including types, applications, construction, components and operating characteristics

typical component wear or defects

typical faults.