Google Links

Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge

Elements and Performance Criteria

  1. Prepare to verify functionality and compliance of electricalappliance
  2. Safety hazards which have not been previously identified are noted and established risk control measures implemented
  3. Appropriate person/s is consulted to ensure the work is coordinated effectively with others involved on the worksite
  4. Inspection and tests are appropriately sequenced in accordance with job schedule
  5. Materials needed for tests and verification are obtained in accordance with workplace procedures and checked against job requirements
  6. Tools, equipment and testing devices needed to verify compliance are obtained in accordance with workplace procedures and checked for correct operation and safety
  7. Visually inspect appliances
  8. Accessories and components are validated as being appropriately rated and meeting functional requirements
  9. Evidence that equipment complies with safety and functional requirements is identified and documented
  10. Unplanned situations are responded to in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
  11. Electrical appliance inspection is carried out efficiently without waste of materials or damage to apparatus, the surrounding environment or services using sustainable energy practices
  12. Conduct electrical appliance tests
  13. Appliance is checked and isolated in accordance with WHS/OHS requirements and workplace procedures
  14. Electrical tests are conducted to verify that the appliance electrical circuit within the appliance is safe and functions as intended
  15. Refrigeration/air conditioning tests are conducted to verify that the refrigeration/air conditioning components and pipe work within the appliance are safe and functions as intended
  16. Testing is carried out efficiently without waste of materials or damage to apparatus, the surrounding environment or services using sustainable energy practices
  17. Report inspection and verification findings
  18. Non-compliance defects are identified and reported in accordance with established procedures
  19. Recommendations for rectifying defects are made in accordance with established procedures
  20. Work completion is documented and appropriate person/s notified in accordance with established procedures

Range Statement

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEE Electrotechnology Training Package Companion Volume Implementation Guide.

Verifying functionality and compliance of air conditioner/refrigeration system appliances must include at least the following:

two types of appliances, including:

conducting visual inspection of appliances

conducting all electrical tests

conducting all refrigeration tests

Electrical testing must include at least the following:

isolation testing

insulation resistance of equipment

resistance of the internal circuits of equipment

polarity of supply and equipment

continuity of earthing

correct electrical connections load current

Refrigeration/air conditioning testing must include at least the following:

pressure test apparatus/circuits

leak test apparatus/circuits

evacuation test apparatus/circuits

compressor efficiency

controls tests

refrigerant charge

operating pressures

system operation system capacity


Performance Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions on at least two separate occasions and include:

applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures and practices, including using of risk control measures

applying sustainable energy principles and practices

dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment

verifying compliance and functionality of electrical refrigeration/air conditioning appliances, including:

acting within regulatory limits

conducting electrical tests safely and correctly

conducting refrigeration/air conditioning tests safely and correctly

identifying non-compliant defects from test results

identifying visual defects

recommending appropriate corrective actions

reporting electrical inspection and verifying findings.


Knowledge Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions and include knowledge of:

mandatory testing and verification requirements

refrigeration/air conditioning appliance efficiency

refrigeration/air conditioning appliance electrical testing techniques, including testing and compliance verification methods

relevant refrigeration/air conditioning appliance manufacturer specifications

relevant safe work method statements (SWMS)/job safety assessments or risk mitigation processes

relevant WHS/OHS legislated requirements

relevant workplace documentation

relevant workplace policies and procedures

visual inspection methods.