Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge

Elements and Performance Criteria

  1. Prepare to inspect and test a RE installation
  2. WHS/OHS hazards are identified, risks assessed, reported to relevant person/s and workplace procedures for risk control measures applied in preparation for work
  3. Relevant documentation and/or industry standards are reviewed and interpreted
  4. Relevant person/s is consulted to ensure the work is coordinated effectively with others
  5. Tools, equipment and testing devices required to verify compliance are obtained in accordance with workplace procedures and checked for correct operation and safety
  6. Preparatory work is checked to ensure no unnecessary damage has occurred and complies with requirements
  7. Visually inspect and conduct safety testing on the RE installation
  8. Circuits/machines/plant are isolated in accordance with WHS/OHS requirements and workplace procedures
  9. Suitability of wiring is checked for the environment/s in which they are installed and protected from damage or overheating
  10. Cable conductor sizes that meet current-carrying capacity requirements and voltage-drop are acquired
  11. Protection methods and devices are validated as meeting coordination requirements for overload and short circuit protection
  12. Switchgear and control gear are validated as correctly rated and appropriate for functional requirements
  13. Evidence that electrical equipment complies with safety requirements is cited
  14. Correct location of earthing system and size of conductors is checked
  15. Markings on switchboards are checked for accuracy, clarity and compliance with requirements
  16. Visual inspection is conducted to ensure that system complies with requirements
  17. Testing is conducted to verify that circuit connections are correct, voltage drop is within limits, circuit protection operates as intended, polarities are correct, and charging rates are compliant with specifications
  18. Report inspection and test findings
  19. Non-compliance defects are identified and reported in accordance with workplace procedures
  20. Recommendations for rectifying defects are made in accordance with workplace procedures
  21. Documentation is completed in accordance with workplace procedures

Range Statement

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEE Electrotechnology Training Package Companion Volume Implementation Guide.

Verifying compliance and functionality of an ELV RE installation must include at least the following:

two electrical installations comprising:

a photovoltaic (PV) array of at least 450 watts

a battery bank

an inverter

a battery charger (or inverter/charger)

a generating set


Performance Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions on at least one occasion and include:

selecting correct tools and testing equipment

identifying visual non-compliance defects

using effective methods for conducting tests

identifying non-compliance from test results

identifying causes of non-compliance

completing mandatory reporting

dealing with unplanned events

applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures and practices, including the use of risk control measures

applying sustainable energy principles and practices

checking isolation of circuits/machines/systems

coordinating work with relevant person/s

determining live electrical testing/measurement requirements

verifying compliance and functionality of extra-low voltage (ELV) renewable energy (RE) installations.


Knowledge Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions and include knowledge of:

RE installations and ELV installation requirements encompassing:

requirements for installation of wiring and equipment

compliant methods for providing protection

requirements for installation planning and selection of equipment

testing and verification requirements

documentation encompassing:

results of tests conducted that comply with requirements and ensure the ELV RE installation is safe, including any formal documents of the results of testing required by authorities

documents of periodic inspection and testing of ELV RE wiring and equipment, including any tagging, in accordance with requirements

energy efficient building design

relevant RE manufacturer specifications

relevant safe work method statements (SWMS)/job safety assessments or risk mitigation processes

relevant WHS/OHS legislated requirements

relevant workplace policies and procedures.