Google Links
Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge
Elements and Performance Criteria
- Plan for the installation, maintenance or fault finding of battery storage systems for grid-connected PV systems
- Carry out the installation, maintenance and fault finding of battery storage systems for grid-connected PV systems
- Job safety analysis is undertaken or safe work method statement is prepared and used to inform work processes in accordance with regulations and workplace procedures
- Battery storage components are installed in accordance with system design documentation, relevant industry standards, regulations and manufacturer specifications
- Inverters are installed in accordance with system design documentation, relevant industry standards, regulations and manufacturer specifications
- System charge controllers are installed in accordance with system design documentation, relevant industry standards, regulations and manufacturer specifications
- Storage system equipment including, cables, protection and isolation equipment, and signs are installed in accordance with system design documentation, relevant industry standards, regulations and manufacturer specifications
- System charge controllers and inverters are programmed in accordance with design documentation, relevant industry standards, regulations and manufacturer specifications
- Required modification to the electrical installation is carried out in accordance with design documentation, regulations and relevant industry standards
- Maintenance checklists are used to identify items needing servicing or replacement
- Required maintenance is performed by servicing or replacing items
- Fault finding techniques are applied to correctly diagnose and rectify system faults
- Testing, commissioning or reinstatement of the system is conducted in accordance with design documentation, regulations, relevant industry standards and manufacturer specifications
- Document the installation, maintenance or fault finding of battery storage systems for grid-connected PV systems
Range Statement
Performance Evidence
Knowledge Evidence
Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria and include knowledge of:battery storage systems:battery storage systems for grid-connected PV systems including:applications for battery storage including:electrical energy supply during grid outageselectrical energy supply direct to loads during periods of high tariffspurpose of each component in battery storage systems for grid-connected PV systemsfunctional block diagrams for typical configurations of battery storage systems for grid-connected PV systems including:multimode inverter/s for connecting to renewable energy, grid, loads and battery storage; these inverter/s provide backup to dedicated loads on grid failure and may:have a built in charge controller for direct connection of a PV array orrequire a separate charge controller to direct current (DC) couple the PV array and batterytwo types of inverters comprising, PV grid-connected inverter/s and multimode inverter/s where:both inverter types are connected to the grid and loads via a switching device that may provide backup to dedicated loads during grid failureboth inverter types are connected to the grid and only the multimode inverter/s may provide backup to dedicated loads on grid failureonly the multimode inverter/s are connected to the grid. The grid-connected inverter/s are alternate current (AC) coupled to the multimode inverter/s and both types can provide backup to dedicated loads on grid failurecharge controllers including:types and applications of charge controllers for different system configurationspecifications of a charge controller, including:output rating DC voltage operating window and/or ratingDC current rating in and outefficiencygrid-connected batteries:battery terms including:nominal voltagecellprimary and secondary cellsbatterycharge and discharge rateamp hour capacitywatt hour capacitystate of charge (SOC)depth of discharge (DOD)battery types including:major features of commercially available types of batteries suitable for battery storage systems for grid-connected PV systemsfactors affecting the life of commercially available types of batteries including the estimation of battery lifecharging regimes suitable for commercially available types of batteriesbattery safety including:hazards associated with handling, installing or maintaining commercially available types of batteries and risk control measuresprocedures for safe disposal of commercially available types of batteriescommon processes leading to battery failure in commercially available batteries including sulphation and stratification in lead acid batteriesgrid-connected inverters:inverters including:differences between multimode and grid connect invertersoutput rating of a multimode inverter/s in relation to:required maximum demandcapacity for battery chargingprogram parameters for a multimode inverter, for the correct operation of the systemgrid-connected storage systems fault finding:fault finding procedures including:fault finding procedures for individual equipmentfault finding procedures for interconnected systemsgrid-connected storage systems installations:installation requirements including: installing battery storage devices in accordance with system design documentation, relevant industry standards, regulations and manufacturer requirementsinstalling inverters suitable for connecting to battery storage in accordance with system design documentation, relevant industry standards, regulations and manufacturer requirementsinstalling charge controllers in accordance with system design documentation, relevant industry standards, regulations and manufacturer requirementsinstalling all balance of system equipment in accordance with system design documentation, relevant industry standards, regulations and manufacturer requirementselectrical drawings including:electrical systems circuit diagrams of typical battery storage systems for grid-connected PV systems including:AC loads being supplied during periods when grid is unavailableall major componentsprotection devicesearthingisolationswitchingmeteringequipment location plan/s to show the locations of equipment, fittings and cablinggrid-connected storage systems maintenance procedures including:maintenance requirements for individual equipmentmaintenance requirements for interconnected systemsgrid-connected storage systems testing and commissioning procedures including:safe testing of equipmentsafe testing of system operationcommissioning of battery storage system. |