  1. Prepare SCADA controlled gas flow and pressure equipment and electronic gas measurement equipment
  2. Work requirements are interpreted from plans, specifications and instructions
  3. Relevant job requirements and workplace procedures for work activities are discussed with relevant person/s to determine and confirm work schedule and respective responsibilities
  4. WHS/OHS, environmental and sustainable energy policies and workplace procedures are determined and confirmed
  5. Hazards are identified, WHS/OHS and risks are assessed, and control measures are prioritised, implemented and monitored in accordance with workplace procedures
  6. Scope of responsibility under the relevant work permits and/or relevant notification is determined and confirmed to access, isolate/de-energise systems and perform work in accordance with job requirements and workplace procedures
  7. Equipment, tools and personal protective equipment (PPE) needed to carry out work activities are identified, scheduled, obtained and checked for correct operation and safety
  8. Appropriate person/s are consulted to ensure work activity is coordinated effectively with person/s involved
  9. Materials, plans, diagrams, drawings and resources required for work are confirmed, scheduled and obtained in accordance with workplace procedures
  10. Relevant responsibilities associated with first aid and related workplace safety procedures at the work site are identified, checked and confirmed
  11. Third-party issues are referred to appropriate person/s in accordance with workplace procedures
  12. Site preparation, safety plan and work schedule are confirmed in accordance with workplace procedures
  13. Maintain SCADA controlled gas flow and pressure equipment and electronic gas measurement equipment
  14. Gas detectors are used to determine work site gas concentration levels and to locate and pinpoint any escaping gas, and supervisor advised immediately if site is unsafe in accordance with workplace procedures
  15. Appropriate materials, tools, equipment and measuring devices are selected and used safely in accordance with workplace procedures
  16. Hazardous activities are conducted safely in accordance with given instructions and to requirements
  17. Work is carried out efficiently, to required industry standard, without waste of materials or damage to apparatus, circuits, and the surrounding environment or services using sustainable energy principles
  18. Hazard warnings and safety signs are identified and assessed as part of WHS/OHS risks and incident control measures and are reported to authorised person/s for directions in accordance with workplace procedures
  19. Electrical isolations are scheduled, and local/remote control actuated and communicated in accordance with workplace procedures
  20. Data on system performance, usage and unplanned events is collected, reviewed and reported in accordance with workplace procedures
  21. Gas station venting and purging operations are undertaken in accordance with workplace procedures
  22. Gas flow regulator and meter runs, and components are set up and operated, and system is vented, purged and pressurised in accordance with workplace procedures
  23. Process variables and set points are taken and required adjustments and repairs are carried out in accordance with workplace procedures
  24. Actuators are isolated/ de-energised in accordance with manufactures instructions and workplace company procedures
  25. Procedures for referring non-routine events to the authorised person/s for directions are followed
  26. Routine work activity quality checks are carried out in accordance with workplace instructions
  27. Complete SCADA maintenancework and relevant documentation
  28. Work site is tidied and made safe in accordance with workplace procedures
  29. Tools, equipment and surplus resources and materials are cleaned, checked and securely stored
  30. Appropriate person/s are notified of work completion in accordance with workplace procedures
  31. Work completion documentation is completed accurately and provided to appropriate person/s in accordance with workplace procedures

Range Statement

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEG Gas Industry Training Package Companion Volume Implementation Guide.

equipment must include the following:

remotely operated valves, types: double block and bleed

remote telemetry units (RTU’s) and controllers

actuators: pneumatic, electric and I To P convertors

pressure controllers

meters: Coriolis and ultrasonic

Note: Fault finding is limited to the component level.

constants and variables must include the following:

monitoring, adjusting and controlling

regulation of flow and pressure

gas measurement

recording and reporting

regulation of the system

equipment

organisational and statutory requirements

third-party issues referred to appropriate person/s must include the following:

low voltage electrical work