Google Links

Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge

Elements and Performance Criteria

  1. Prepare to monitor and operate gas flow control, measuring and regulating devices
  2. Relevant requirements and workplace procedures for work activities are communicated to relevant person/s
  3. WHS/OHS, environmental and sustainable energy workplace policies and procedures related to the monitoring and operating of complex flow controls are obtained, confirmed and communicated to relevant person/s
  4. Work activities are prioritised and sequenced in consultation with relevant person/s for completion within acceptable timeframes and in accordance with workplace procedures
  5. Risk control measures for identified hazards are prioritised, implemented and monitored in accordance with work schedule
  6. Relevant work permits are obtained to access, isolate/de-energise systems and perform work in accordance with job requirements and workplace procedures
  7. Resources, appropriately licensed person/s, equipment, tools and personal protective equipment (PPE) required for work activities are identified, scheduled and confirmed in a safe working order
  8. Liaison and communication with authorised person/s, authorities, clients and land owners is undertaken so work activities can be carried out, as required
  9. Persons participating in work activities are fully briefed and respective responsibilities confirmed, as required, in accordance with workplace procedures
  10. Monitor and operate gas flow control, measuring and regulating devices
  11. Dealings with customers are consistent with workplace procedures and the specific needs of customers are identified and considered in targeting client service
  12. Monitoring and operating complex flow control devices workplace procedures are applied to ensure job is completed in agreed timeframe and to quality industry standards with a minimum of waste in accordance with job requirements
  13. Routine inspections of system are scheduled and monitored in accordance with the work schedule and workplace procedures
  14. Hazard warnings and safety signs are identified and hazards WHS/OHS risks assessed and reported to authorised person/s for directions in accordance with workplace procedures
  15. Data on system performance and usage is collected, analysed and reported with any unplanned events in the monitoring and operation of complex flow control in accordance with workplace procedures
  16. Ongoing quality checks of work activities are undertaken in accordance with given instructions and workplace procedures
  17. Control and adjust flows and complete records and reports
  18. Accidents and injuries are reported, as required in accordance with workplace procedures
  19. Gas flows and diversions are determined to facilitate repair or emergency activities in accordance with organisational job requirements
  20. Process faults and operational conditions of the gas system are identified, addressed and reported in accordance with organisational requirements
  21. Work completion records, reports and documentation are finalised, processed and appropriate person/s notified

Range Statement

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEG Gas Industry Training Package Companion Volume Implementation Guide.

competency must demonstrate monitoring and operating of complex gas flow control, measuring and regulating devices for gas pressure and flow control with the following:

custody transfer stations

inlets and city gates

scraper stations

gas storage facilities

main line valves

constants and variables must include the following:

inspecting and controlling

regulation of flow and pressure

measuring

recording and reporting

regulation of flow and regulation devices

regulation of the system

equipment

organisational and statutory requirements

equipment must include at least two (2) of the following procedures:

pressure controllers - operation and maintenance commissioning/setting

troubleshooting

pressure boosters minor repairs

types/models

basic regulators must include at least two (2) of the following:

sleeve types

diaphragm types

hydraulic plug types

distribution valves must include the following:

ball, plug, gate instrument and butterfly valves

meters must include at least two (2) of the following:

meters diaphragm meters

rotary meters

turbine meters

oil changing

operational checks must include at least three (3) of the following:

single run units

dual run units

district regulators

field regulators

pressure alterations must include the following:

industrial units

regulator stations

distribution mains

flaring and purging must include the following:

industrial units

regulator stations

distribution mains

overpressure protection systems - function and operation must include at least three (3) of the following:

over-pressure shut-off (OPSO)

internal pressure relief systems

pressure relief valves

slam shut systems

valve actuator & control systems

documentation must include the following:

risk assessments

timesheets

completing worksheets

notifications and work permits

equipment checklists

meter bypass forms

service orders

pressure recording charts

regulator station heaters must include the following:

heater: scheduled maintenance procedures

heater: operational checks

water quality testing