  1. Prepare to monitor and operate complex gas flow control, measuring and regulating devices
  2. Monitor and operate complex gas flow control, measuring and regulating devices
  3. Control and adjust flows and compile records and reports

Required Skills

This describes the skills and knowledge and their level required for this unit

Evidence shall show that knowledge has been acquired of safe working practices for carrying out work in a gas industry environment

All knowledge and skills detailed in this unit should be contextualised to current industry practices and technologies

KSGA

Complex flow control device operation

Evidence shall show an understanding of monitor and operate complex flow control measuring and regulating devices for gas distribution systems in accordance with relevant legislation standards codes and established procedures to an extent indicated by the following aspects

T Basic principles of SCADA use in monitoring and control of applicable organisational gas infrastructure

T Component types function and operation including

data collection and equipment control functions including

Remote Terminal Unit RTU

system controller interface such as Human Machine Interface HMI

T Remote Telemetry Units RTUs and associated controller operation including

start up and shut down of process controllers and RTU equipment

adjustment of process set point control and status eg localremote and automanual

alarm monitoring acknowledgement prioritisation and escalation

alarm inhibitenablementdisablement

T SCADA operated gas conditioning and monitoring equipment

principles of operation

components

fault finding adjustments and minor repairs

T SCADA operated pressure control equipment

types

Air loaded diaphragm and sleeve regulators

SCADA operated valves

ALBs

principles of operation

fault finding adjustments and minor repairs

T SCADA gas flow measurement equipment

types

Coriolis meters

Ultrasonic meters

Turbine meters

operation

fault finding adjustments and minor repairs

T SCADA gas station alarms and safety devices

types

operation

fault finding adjustments and minor repairs

T SCADA operated gas station valves

types

operation

maintenance

fault finding adjustments and minor repairs

T SCADA controlled gas station venting purging and pressurisation operations

T Gas station operation requirements and procedures

change over regulator and meter runs

change over filtersseparators

purge and pressurise station

adjust set points

T Manufactures specifications manuals and procedures

T Organisations gas facility manuals schematics SCADA displays switches PIDs and procedures

T Relevant Legislation Standards Codes and Regulations

Evidence Required

The Evidence Guide forms an integral part of this Unit and shall be used in conjunction with all components parts of this unit and performed in accordance with the Assessment Guidelines of this Training Package

Overview of Assessment

Longitudinal competency development approaches to assessment such as Profiling require data to be reliably gathered in a form that can be consistently interpreted over time This approach is best utilised in Apprenticeship programs and reduces assessment intervention It is the Industrys preferred model for apprenticeships However where summative or final assessment is used it is to include the application of the competency in the normal work environment or at a minimum the application of the competency in a realistically simulated work environment It is recognised that in some circumstances assessment in part or full can occur outside the workplace However it must be in accord with Industry and Regulatory policy in this regard

Methods chosen for a particular assessment will be influenced by various factors These include the extent of the assessment the most effective locations for the assessment activities to take place access to physical resources additional safety measures that may be required and the critical nature of the competencies being assessed

The critical safety nature of working with electricity electrical equipment gas or any other hazardous substancematerial carries risk in deeming a person competent Hence sources of evidence need to be rich in nature so as to minimise error in judgment

Activities associated with normal every day work have a bearing on the decision as to how much and how detailed the data gathered will contribute to its richness Some skills are more critical to safety and operational requirements while the same skills may be more or less frequently practiced These points are raised for the assessors to consider when choosing an assessment method and developing assessment instruments Sample instruments are included for Assessors in the Assessment Guidelines of this Training Package

Critical aspects of evidence required to demonstrate competency in this unit

Before the critical aspects of evidence are considered all prerequisites shall be met

Evidence for competence in this unit shall be considered holistically Each element and associated Performance Criteria shall be demonstrated on at least two occasions in accordance with the Assessment Guidelines UEG Evidence shall also comprise

A representative body of work performance demonstrated within the timeframes typically expected of the discipline work function and industrial environment In particular this shall incorporate evidence that shows a candidate is able to

Implement Occupational Health and Safety workplace procedures and practices including the use of risk control measures as specified in the Performance Criteria and range

Apply sustainable energy principles and practices as specified in the Performance Criteria and range

Demonstrate an understanding of the required knowledge and as described in this unit to such an extent that the learners performance outcome is reported in accordance with the preferred approach namely a percentile graded result where required by the regulated environment

Demonstrate an appropriate level of employability skills

Conduct work observing the relevant AntiDiscrimination legislation regulations polices and workplace procedures

Demonstrate performance across a representative range of contexts from the prescribed items below

Monitor and operate complex flow control measuring and regulating devices for gas distribution systems in accordance with relevant legislation code regulations and procedures as described in Range Statement and including

Range of toolsequipmentproceduresworkplace

Group No

The minimum number of items on which skill is to be demonstrated

Item List

A

At least

Interpret technical drawings and symbols

Selection of appropriate tools and equipment

System knowledge of TP HP MP LP

Relevant knowledge of AS Distribution Code

B

All

Auxiliary control systems knowledge amp understanding

Wide open monitor operation

Two stage pressure reduction with monitor override

C

All

SCADA Operation awareness

SCADA control system layout and operation awareness

D

At least

Pressure Controllers operation amp maintenance CommissioningSetting

Troubleshooting

Pressure Boosters minor repairs

typesmodels

E

At least

Basic regulators

Sleeve types

Diaphragm types

Hydraulic Plug types

F

All

Distribution Valves

Ball Plug Gate Instrument amp Butterfly valves

G

At least

Meters Diaphragm meters

Rotary meters

Turbine meters

Oil changing

H

At least

Operational checks

Single run units

Dual run units

District regulators

Field regulators

I

At least

Pressure alterations

Industrial units

Regulator Stations

Distribution mains

J

At least

Flaring amp Purging

Industrial units

Regulator Stations

Distribution mains

K

At least

Overpressure protection systems function amp operation

OPSO

Internal pressure relief systems

Pressure relief valves

Slam Shut systems

Valve Actuator amp control systems

L

All

Paperwork

Risk assessments

Time sheets

Completing work sheets

Notifications and work permits

Equipment check lists

Meter Bypass forms

Service orders

Pressure recording charts

M

All

Regulator station heaters

Heater scheduled maintenance procedures

Heater operational checks

Water quality testing

N

At least one occasion

Dealing with an unplanned event by drawing on required knowledge and skills to provide appropriate solutions incorporated in the holistic assessment with the above listed items

Context of and specific resources for assessment

This unit should be assessed as it relates to normal work practice using procedures information and resources typical of a workplace This should include

OHS policy and work procedures and instructions

Suitable work environment facilities equipment and materials to undertake actual work as prescribed by this Competency Standard Unit

Appropriate environmental regulation and work practices

Appropriate organisational requirements

In addition to the resources listed above in Context of and specific resources for assessment evidence should show demonstrated competency in monitoring and operating complex flow control measuring and regulating devices for gas pressure control

Assessment of this competency must also be undertaken in either an actual workplace or under a simulated work environment Assessment must also integrate the employability skills

Method of assessment

This Competency Standard Unit shall be assessed by methods given in Volume Part Assessment Guidelines

Note Competent performance with inherent safe working practices is expected in the Industry to which this Competency Standard Unit applies This requires that the specified required Knowledge and Skills are assessed in a structured environment which is primarily intended for learningassessment and incorporates all necessary equipment and facilities for learners to develop and demonstrate the required knowledge and skills described in this unit

Concurrent assessment and relationship with other units

There are no recommended concurrent assessments with this unit however in some cases efficiencies may be gained in terms of learning and assessment effort being concurrently managed with allied competency standard units where listed

UEGNSGA

UEGNSG132A

Carry out basic work activities in a gas industry work environment

UEGNSGA

UEGNSG141A

Apply Occupational Health and Safety regulations codes and practices in the gas supply industry

UEGNSGA

UEGNSG140A

Comply with environmental policies and procedures in the utilities industry

UEGNSGA

UEGNSG134A

Establish a utilities infrastructure work site

BSBFLMB

BSBFLM312B

Contribute to team effectiveness

BSBFLMC

BSBFLM303C

Contribute to effective workplace relationships


Range Statement

9) This relates to the competency standard unit as a whole providing the range of contexts and conditions to which the Performance Criteria apply. It allows for different work environments and situations that will affect performance.

This Competency Standard Unit shall be demonstrated in relation to the monitoring and operating of complex flow control, measuring and regulating devices for gas pressure and flow control in:

Custody transfer stations

Inlets and city gates

Scraper stations

Gas storage facilities

Main Line Valves

The following constants and variables included in the element/Performance Criteria in this unit are fully described in the Definitions Section of this volume and form an integral part of the Range Statement of this unit:

Inspecting and controlling

Regulation of flow and pressure

Measuring

Recording and reporting

Regulation of flow and regulation devices

Regulation of the system

Equipment

Organisational and statutory requirements