Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge
Elements and Performance Criteria
- Plan and prepare work
- Work requirements including the use of Personal Protective Equipment (PPE), permits and risk control measures are identified, in accordance with workplace procedures, from relevant personnel and documentation
- Inspection, preoperational checks and preparations for flue gas (NOx) mitigation service are carried out, in accordance with workplace procedures and manufacturers' recommendations procedures
- Flue gas (NOx) mitigation plant operational prerequisites are established, in accordance with workplace procedures and manufacturers' recommendations
- Sequence for recommissioning of flue gas (NOx) mitigation plant is determined to suit existing circumstances, in accordance with workplace procedures and site requirements
- Operate flue gas (NOx) mitigationplant
- Flue gas (NOx) mitigation plant is monitored and observed, in accordance with workplace procedures, to detect deviations from normal operating conditions
- Corrective actions are taken to rectify flue gas (NOx) mitigation abnormalities, in accordance with workplace procedures, industry standards and site requirements
- Test flue gas (NOx) mitigationplant operation
- Flue gas (NOx) mitigation plant is observed for correct operational response, in accordance with workplace procedures
- Corrective action is taken, in accordance with workplace procedures, when response does not meet with documentation, flue gas (NOx) mitigation plant integrity or personnel safety requirements
- Flue gas (NOx) mitigation plant is returned to required operational status upon completion of test, in accordance with workplace procedures
- Analyse flue gas (NOx) mitigationplant faults
- Corrective action is taken, in accordance with workplace procedures
- Flue gas (NOx) mitigation plant integrity and personnel safety is maintained, in accordance with workplace procedures, and in consultation with appropriate personnel and technical and operational documentation
- Monitor and inspect flue gas (NOx) mitigationplant
- Flue gas (NOx) mitigation plant is monitored and inspected, in accordance with workplace procedures, for normal operation or to detect deviations
- Appropriate personnel are notified, in accordance with workplace procedures, when defects are detected
- Complete documentation
- Documentation is updated, in accordance with workplace procedures
Range Statement