Certificate III in Electrical Machine Repair
Scope
This qualification provides competencies to overhaul and repair motor, transformer and control gear including rewinding
Scope
This qualification provides competencies to overhaul and repair motor, transformer and control gear including rewinding
Completion requirements
The requirements for granting this qualification will be met when competency is demonstrated and achieved for:
All the Core competency standard units, defined in the Core Competency Standard Units table below and
A combination of Elective competency standard units to achieve a total weighting of 180 points in accordance with the Elective Competency Standard Units table below.
Core Competency Standard Units All Core competency standard units to be achieved | Weighting Points | |
Participate in electrical machine repair work and competency development activities | 60 | |
Apply Occupational Health Safety regulations, codes and practices in the workplace | 20 | |
Fabricate, dismantle, assemble of utilities industry components | 40 | |
Solve problems in d.c. circuits | 80 | |
Fix and secure electrotechnology equipment | 20 | |
Use drawings, diagrams, schedules, standards, codes and specifications | 40 | |
Document and apply measures to control OHS risks associated with electrotechnology work | 20 | |
Solve problems in single and three phase low voltage machines | 80 | |
Solve problems in electromagnetic devices and related circuits | 60 | |
Solve problems in low voltage a.c. circuits | 80 | |
Terminate cables, cords and accessories for low voltage circuits | 40 | |
Carry out repairs to electrical apparatus | 40 | |
Wind electrical coils | 40 | |
Place and connect electrical coils | 40 | |
Rewind LV three phase induction machines rated for low voltage | 60 | |
Conduct electrical tests on LV electrical machines | 40 | |
Repair mechanical and electrical components of electrical machines | 40 | |
Apply environmental and sustainable procedures in the energy sector | 20 | |
Disconnect / reconnect motors connected to low voltage installation wiring | 60 | |
Total points in core | 880 |
Elective Competency Standard Units Complete Elective units to achieve a total of weighting of 180 points from the following groups: | |||
Group | Minimum points | Maximum points | |
A | Imported and Common Elective Units Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 3. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. | 0 | 60 |
B | Qualification Elective Units You may select all your elective units from this Group | 120 | 180 |
Group A Imported and Common Elective Units You may complete units to a maximum weighting of 60 | Weighting Points | |
Maintain documentation | 20 | |
Source and purchase material/parts for installation or service jobs | 20 | |
Provide quotations for installation or service jobs | 20 | |
Deliver a service to customers | 20 | |
Use basic computer applications relevant to a workplace | 20 | |
Comply with scheduled and preventative maintenance program processes | 20 | |
Provide basic instruction in the use of electrotechnology apparatus | 20 | |
Work safely in the construction industry | 10 | |
Perform CPR | 10 | |
Apply first aid | 10 | |
Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 3. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. Note: For further information see Application of the NQC Flexibility Formula, UEE11 Electrotechnology Training Package, Version 1, Volume 1 Qualification Framework | Up to 60 points | |
Group B Qualification Elective Units Complete units to a minimum weighting of 120 You may select all your elective units from this Group | Weighting Points | |
Use engineering applications software on personal computers | 40 | |
Overhaul and repair switchgear and controlgear | 60 | |
Rewind single phase machines | 40 | |
Rewind LV direct current machines | 60 | |
Conduct mechanical tests of LV electrical machines | 40 | |
Develop, enter and verify discrete control programs for programmable controllers | 60 | |
Service small electrical appliances and power tools | 60 | |
Locate and rectify faults in low voltage motors using set procedures | 20 | |
Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply | 20 | |
Attach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supply | 20 |
Note:
1. Prerequisite pathways shall be identified and met for all elective units selected.
2. In selecting elective units considerations to career planning advice should be given to units that form part of a prerequisite pathway for the progression to achieve particular competencies or qualification at a higher level.
END OF QUALIFICATION
Not applicable.
Not applicable.
Not applicable.
Not applicable.