Advanced Diploma of Air-conditioning and Refrigeration Engineering

Scope

This qualification provides competencies to design and validate/evaluate refrigeration and air conditioning equipment and systems, manage risk, estimate and manage projects and provide technical advice/sales. It includes regulatory requirements for purchasing and handling refrigerants.

It develops competencies in the ethical and responsible application of mathematics, science, engineering techniques, Standards and Codes of Practice, engineering design practices, supervision and management of physical, human and financial resources in Refrigeration and Air Conditioning engineering.

Note:

The Ozone Protection and Synthetic Greenhouse Gas Legislation Amendment Bill 2003 apply to this qualification. Prior to planning the delivery of any training and/or assessment activities all legislative and regulatory requirements shall be identified and included.

The core competencies of this qualification meet the prescribed requirements for Engineering Associate membership of Engineers Australia.

Participants seeking Engineers Australia membership should ensure that their training provider is accredited by that body to provide Engineering Education Programs at the level of Engineering Associate.


Subjects

Completion requirements

The requirements for granting this qualification will be met when competency is demonstrated and achieved for:

All the Core competency standard units, defined in the Core Competency Standard Units table below and

A combination of Elective competency standard units to achieve a total weighting of 250 points in accordance with the Elective Competency Standard Units table below.

Note: add topic UEENEEJ109A - Those holding an Certificate III in Refrigeration and Air-conditioning trade qualification or equivalent" meet the requirements of this unit and its pre-requisite requirements.

Core Competency Standard Units

All Core competency standard units to be achieved

Weighting Points

add topic UEENEED104A

Use engineering applications software on personal computers

40

add topic UEENEEE011C

Manage risk in electrotechnology activities

60

add topic UEENEEE080A

Apply industry and community standards to engineering activities

20

add topic UEENEEE083A

Establish and follow a competency development plan in an electrotechnology engineering discipline

120

add topic UEENEEE101A

Apply Occupational Health and Safety regulations, codes and practices in the workplace

20

add topic UEENEEE102A

Fabricate, assemble and dismantle utilities industry components

40

add topic UEENEEE103A

Solve problems in ELV single path circuits

40

add topic UEENEEE105A

Fix and secure electrotechnology equipment

20

add topic UEENEEE107A

Use drawings, diagrams, schedules, standards, codes and specifications

40

add topic UEENEEE117A

Implement and monitor energy sector OHS policies and procedures

20

add topic UEENEEE124A

Compile and produce an energy sector detailed report

60

add topic UEENEEE137A

Document and apply measures to control OHS risks associated with electrotechnology work

20

add topic UEENEEJ040B

Manage refrigeration and air conditioning projects

40

add topic UEENEEJ069B

Plan refrigeration and air conditioning projects

60

add topic UEENEEJ102A

Prepare and connect refrigerant tubing and fittings

30

add topic UEENEEJ103A

Establish the basic operating conditions of vapour compression systems

60

add topic UEENEEJ104A

Establish the basic operating conditions of air conditioning systems

20

add topic UEENEEJ106A

Install refrigerant pipe work, flow controls and accessories

60

add topic UEENEEJ107A

Install air conditioning and refrigeration systems, major components and associated equipment

80

add topic UEENEEJ108A

Recover, pressure test, evacuate, charge and leak test refrigerants

60

add topic UEENEEJ109A

Verify functionality and compliance of refrigeration and air conditioning installations

20

add topic UEENEEJ110A

Select refrigerant piping, accessories and associated controls

50

add topic UEENEEJ111A

Diagnose and rectify faults in air conditioning and refrigeration systems and components

40

add topic UEENEEJ113A

Commission air conditioning and refrigeration systems

40

add topic UEENEEJ127A

Establish the thermodynamic parameters of refrigeration and air conditioning systems

80

add topic UEENEEJ128A

Produce HVAC/R system design drawings

80

add topic UEENEEJ129A

Establish heat loads for commercial refrigeration and/or air conditioning applications

80

add topic UEENEEJ138A

Analyse vibration and noise in refrigeration and air conditioning systems

80

add topic UEENEEJ153A

Find and rectify faults in motors and associated controls in refrigeration and air conditioning systems

50

add topic UEENEEJ164A

Analyse the operation of HVAC air and hydronic systems

80

add topic UEENEEJ165A

Evaluate thermodynamic and fluid parameters of refrigeration systems

100

add topic UEENEEJ170A

Diagnose and rectify faults in air conditioning and refrigeration control systems

70

add topic UEENEEJ192A

Analyse the psychrometric performance of HVAC/R systems

50

add topic UEENEEJ194A

Solve problems in low voltage refrigeration circuits

40

add topic UEENEEK132A

Develop strategies to address environmental and sustainability issues in the energy sector

20

add topic UEENEEP012A

Disconnect / reconnect composite appliances connected to low voltage installation wiring

60

add topic UEENEEP017A

Locate and rectify faults in low voltage composite appliances using set procedures

20

add topic UEENEEP024A

Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply

20

add topic UEENEEP025A

Attach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supply

20

Total points in core

1910

Elective Competency Standard Units

Complete Elective units to achieve a total of weighting of 250 points from the following groups:

Group

Minimum points

Maximum points

A

Imported and Common Elective Units

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 6. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

0

120

B

Qualification Elective Units

0

30

C

Qualification Elective Units

0

60

D

Qualification Elective Units

0

120

E

Qualification Elective Units

You may select all of your elective units from this Group

120

250

Group A Imported and Common Electives Units

You may complete units to a maximum weighting of 120

Weighting Points

add topic BSBMGT502B

Manage people performance

70

add topic BSBINM501A

Manage an information or knowledge management system

50

add topic BSBMGT516C

Facilitate continuous improvement

60

add topic BSBINN502A

Build and sustain an innovative work environment

50

add topic BSBWOR502B

Ensure team effectiveness

60

add topic CPCCOHS1001A

Work safely in the construction industry

10

add topic HLTAID001

Provide cardiopulmonary resuscitation

10

add topic MEM16006A

Organise and communicate information

20

add topic MEM16008A

Interact with computing technology

20

add topic MEM30001A

Use computer aided drafting systems to produce basic engineering drawings

40

add topic MEM30002A

Produce basic engineering graphics

40

add topic MEM30003A

Produce detailed engineering drawings

80

add topic MEM30004A

Use CAD to create and display 3D models

40

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 6. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

Note: For further information see Application of the NQC Flexibility Formula, add topic UEE11 Electrotechnology Training Package, Version 1, Volume 1 Qualification Framework

Up to 120 points

Group B Qualification Elective Units

You may complete units to a maximum weighting of 30

Weighting Points

add topic UEENEEJ114A

Resolve problems in hydronic systems

40

add topic UEENEEJ115A

Resolve problems in beverage dispensers

40

add topic UEENEEJ116A

Resolve problems in transport refrigeration systems

20

add topic UEENEEJ117A

Resolve problems in ultra-low temperature refrigeration systems

20

add topic UEENEEJ118A

Resolve problems in post mix refrigeration systems

20

add topic UEENEEJ119A

Resolve problems in ice making systems

20

add topic UEENEEJ166A

Resolve problems in dairy refrigeration systems

20

add topic UEENEEJ167A

Resolve problems in central plant air conditioning systems

40

add topic UEENEEJ168A

Maintain microbial control of refrigeration and air conditioning systems

20

add topic UEENEEJ171A

Resolve problems in refrigerated beverage vending cabinets

20

add topic UEENEEJ174A

Apply safety awareness and legal requirements for hydrocarbon refrigerants

10

add topic UEENEEJ175A

Service and repair self contained hydrocarbon air conditioning and refrigeration systems

20

add topic UEENEEJ176A

Install and commission hydrocarbon refrigeration systems, components and associated equipment

20

add topic UEENEEJ178A

Apply safety awareness and legal requirements for ammonia refrigerant

10

add topic UEENEEJ179A

Repair and service ammonia refrigeration systems

20

add topic UEENEEJ180A

Install and commission ammonia refrigeration systems, components and associated equipment

20

add topic UEENEEJ182A

Repair and service secondary refrigeration systems

20

add topic UEENEEJ184A

Apply safety awareness and legal requirements for carbon dioxide refrigerant

10

add topic UEENEEJ185A

Repair and service carbon dioxide refrigeration systems

20

add topic UEENEEJ186A

Install and commission carbon dioxide refrigeration systems, components and associated equipment

20

add topic UEENEEJ188A

Repair and service self contained carbon dioxide refrigeration and heat pump systems

20

Group C Qualification Elective Units

You may complete units to a maximum weighting of 60

Weighting Points

add topic UEENEEC005B

Estimate electrotechnology projects

40

add topic UEENEEJ130A

Produce HVAC/R control system diagrams

40

add topic UEENEEJ190A

Select basic commercial refrigeration system equipment, components and accessories

40

add topic UEENEEJ191A

Select residential air conditioning system equipment, components and accessories

40

add topic UEENEEK145A

Implement and monitor energy sector environmental and sustainable policies and procedures

20

Group D Qualification Elective Units

You may complete units to a maximum weighting of 120

Weighting Points

add topic UEENEEC006B

Prepare tender submissions for electrotechnology projects

60

add topic UEENEEE015B

Develop design briefs for electrotechnology projects

40

add topic UEENEEE126A

Provide solutions to basic engineering computational problems

60

add topic UEENEEJ132A

Design commercial refrigeration systems and select components

80

add topic UEENEEJ133A

Design industrial refrigeration systems and select components

80

add topic UEENEEJ134A

Design heating, ventilation and air conditioning (HVAC) systems and select components

60

add topic UEENEEJ135A

Design control systems for refrigeration or heating, ventilation and air conditioning systems

80

add topic UEENEEJ136A

Evaluate and report on building services energy management systems

80

add topic UEENEEJ137A

Evaluate and report on the indoor air quality of buildings

40

add topic UEENEEJ177A

Design hydrocarbon refrigerated systems

40

add topic UEENEEJ181A

Design ammonia refrigerated systems

40

add topic UEENEEJ183A

Design secondary refrigerant systems

40

add topic UEENEEJ187A

Design carbon dioxide refrigerated systems

40

add topic UEENEEK151A

Develop effective engineering strategies for energy reduction in buildings

60

Group E Qualification Elective Units

You must complete units to a minimum weighting of 120

You may select all your elective units from this Group

Weighting Points

add topic UEENEEC007B

Manage contract variations

40

add topic UEENEEJ139A

Develop specifications and prepare drawings for HVAC/Refrigeration projects

60

add topic UEENEEJ141A

Design complex commercial refrigeration systems and select equipment

40

add topic UEENEEJ142A

Design complex industrial refrigeration systems and select equipment

40

add topic UEENEEJ143A

Design complex air conditioning systems and select equipment

120

add topic UEENEEJ144A

Design mechanical ventilation/exhaust systems and select equipment

40

add topic UEENEEJ145A

Design hydronic systems and select equipment

80

add topic UEENEEJ146A

Design complex control systems for refrigeration or heating, ventilation, air conditioning systems

80

add topic UEENEEJ147A

Audit energy use for commercial HVAC/Refrigeration systems

40

add topic UEENEEJ148A

Audit HVAC/R control systems for compliance with regulations and standards

60

add topic UEENEEJ149A

Develop heat exchanger design specifications

80

add topic UEENEEJ150A

Evaluate new and alternative technologies applicable to electrotechnology applications

40

Note:

1. Pre-requisite pathways shall be identified and met for all elective units selected.

2. In selecting elective units considerations to career planning advice should be given to units that form part of a pre-requisite pathway for the progression to achieve particular competencies or qualification at a higher level

3. Registered training organisations shall also provide information related to the relevant pathway(s) that may be taken to achieve paraprofessional status ("associate membership") with a professional engineering membership organisation.

END OF QUALIFICATION


Pathways...

    Not Applicable


Entry Requirements

Not Applicable


Licensing Information

Not Applicable


Employability Skills

Not Applicable