• MEM18048B - Fault find and repair/rectify basic electrical circuits

Unit of Competency Mapping – Information for Teachers/Assessors – Information for Learners

MEM18048B Mapping and Delivery Guide
Fault find and repair/rectify basic electrical circuits

Version 1.0
Issue Date: April 2024


Qualification -
Unit of Competency MEM18048B - Fault find and repair/rectify basic electrical circuits
Description This unit covers locating and repairing and rectifying faults in non-interconnected electrical circuits.
Employability Skills This unit contains employability skills.
Learning Outcomes and Application This unit applies to working on basic circuit which is defined as a single circuit with a single output. A single circuit may be controlled by one or more devices and the output may control one or more devices.Band: AUnit Weight: 12
Duration and Setting X weeks, nominally xx hours, delivered in a classroom/online/blended learning setting.
Prerequisites/co-requisites Path 1MEM09002B Interpret technical drawing MEM10002B Terminate and connect electrical wiring MEM10003B Install and test electrical wiring and circuits (up to 1000 volts a.c./1500 volts a.c.) MEM12002B Perform electrical/electronic measurement MEM12023A Perform engineering measurements MEM18001C Use hand tools MEM18002B Use power tools/hand held operations MEM18049C Disconnect/reconnect fixed wired equipment up to 1000 volts a.c./1500 volts d.c.
Competency Field Maintenance and diagnostics
Development and validation strategy and guide for assessors and learners Student Learning Resources Handouts
Activities
Slides
PPT
Assessment 1 Assessment 2 Assessment 3 Assessment 4
Elements of Competency Performance Criteria              
Element: Locate fault
  • Circuit function and characteristics are determined and understood by reference to circuit diagrams, specifications, schematics and/or consultation with technical adviser.
  • Where appropriate, built-in fault indicators and error codes are examined and correctly interpreted, and results are recorded to standard operational procedures.
  • Where appropriate, circuit is correctly isolated from power supply.
  • Faults are verified or localised using correct and appropriate techniques, procedures, tools and test equipment.
  • Faults are recorded to standard operating procedures.
       
Element: Repair/rectify fault(s)
  • Using correct and appropriate techniques, procedures, tools and equipment, circuit/s is repaired, replaced or adjusted to specifications or manufacturers' requirements.
  • Circuit/s is checked and tested using correct and appropriate techniques, procedures, tools and equipment for compliance with site or manufacturers' specifications.
  • Where appropriate, repair/rectification report is recorded to standard operating procedures.
       


Evidence Required

List the assessment methods to be used and the context and resources required for assessment. Copy and paste the relevant sections from the evidence guide below and then re-write these in plain English.

The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.

Overview of assessment

A person who demonstrates competency in this unit must be able to fault find and repair/rectify basic electrical circuits. Competency in this unit cannot be claimed until all prerequisites have been satisfied.

Critical aspects for assessment and evidence required to demonstrate competency in this unit

Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.

Context of and specific resources for assessment

This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is the candidate is not in productive work, then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.

This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with fault finding and repair/rectify of basic electrical circuits, or other units requiring the exercise of the skills and knowledge covered by this unit.

Method of assessment

Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.

Guidance information for assessment


Submission Requirements

List each assessment task's title, type (eg project, observation/demonstration, essay, assignment, checklist) and due date here

Assessment task 1: [title]      Due date:

(add new lines for each of the assessment tasks)


Assessment Tasks

Copy and paste from the following data to produce each assessment task. Write these in plain English and spell out how, when and where the task is to be carried out, under what conditions, and what resources are needed. Include guidelines about how well the candidate has to perform a task for it to be judged satisfactory.

Required skills

Look for evidence that confirms skills in:

using diagnostic skills to identify correct and faulty operation

interpreting and using circuit diagrams, specifications

locating reading/recording built-in fault indicators

obtaining error code interpretation documents

isolating electrical circuits from the power supply

tagging isolated circuits

verifying circuit isolation

confirming/localising circuit faults using appropriate test equipment, work techniques and tools

recording/reporting faults in electrical circuits

repairing/adjusting electric circuits

confirming circuit/s against specification

recording rectification of the circuit(s)

Required knowledge

Look for evidence that confirms knowledge of:

circuit characteristics

hazards associated with the electrical circuit(s)

relevant regulatory requirements

errors indicated by built-in devices

circuit isolation procedures

common electrical test instruments and their application

common techniques for testing electrical circuits

recording/reporting requirements for electrical circuit faults

appropriate techniques/procedures for returning the circuit/s to specification

site/manufacturers' circuit specifications

requirements for recording circuit rectifications

The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.

Circuit

A basic circuit is defined as a single circuit with a single output. A single circuit may be controlled by one or more devices and the output may control one or more devices

Appropriate techniques

Testing for voltage, current, frequency, polarity, phase, circuit continuity, insulation resistance, earth continuity etc.

Test equipment

Continuity testers, ammeters, voltmeters, multimeters, tong testers, wattmeters, cathode ray oscilloscopes, etc.

Copy and paste from the following performance criteria to create an observation checklist for each task. When you have finished writing your assessment tool every one of these must have been addressed, preferably several times in a variety of contexts. To ensure this occurs download the assessment matrix for the unit; enter each assessment task as a column header and place check marks against each performance criteria that task addresses.

Observation Checklist

Tasks to be observed according to workplace/college/TAFE policy and procedures, relevant legislation and Codes of Practice Yes No Comments/feedback
Circuit function and characteristics are determined and understood by reference to circuit diagrams, specifications, schematics and/or consultation with technical adviser. 
Where appropriate, built-in fault indicators and error codes are examined and correctly interpreted, and results are recorded to standard operational procedures. 
Where appropriate, circuit is correctly isolated from power supply. 
Faults are verified or localised using correct and appropriate techniques, procedures, tools and test equipment. 
Faults are recorded to standard operating procedures. 
Using correct and appropriate techniques, procedures, tools and equipment, circuit/s is repaired, replaced or adjusted to specifications or manufacturers' requirements. 
Circuit/s is checked and tested using correct and appropriate techniques, procedures, tools and equipment for compliance with site or manufacturers' specifications. 
Where appropriate, repair/rectification report is recorded to standard operating procedures. 

Forms

Assessment Cover Sheet

MEM18048B - Fault find and repair/rectify basic electrical circuits
Assessment task 1: [title]

Student name:

Student ID:

I declare that the assessment tasks submitted for this unit are my own work.

Student signature:

Result: Competent Not yet competent

Feedback to student

 

 

 

 

 

 

 

 

Assessor name:

Signature:

Date:


Assessment Record Sheet

MEM18048B - Fault find and repair/rectify basic electrical circuits

Student name:

Student ID:

Assessment task 1: [title] Result: Competent Not yet competent

(add lines for each task)

Feedback to student:

 

 

 

 

 

 

 

 

Overall assessment result: Competent Not yet competent

Assessor name:

Signature:

Date:

Student signature:

Date: