• MSATMVER403A - Verify inspector's class reference standards

Unit of Competency Mapping – Information for Teachers/Assessors – Information for Learners

MSATMVER403A Mapping and Delivery Guide
Verify inspector's class reference standards

Version 1.0
Issue Date: April 2024


Qualification -
Unit of Competency MSATMVER403A - Verify inspector's class reference standards
Description This unit of competency covers the ability to calibrate reference standards to the inspector's class level in accordance with standard calibration procedures. These procedures specify all associated reference standards, equipment and methods to be used and the required parameters, quantities and ranges to be tested, including the criteria for validation or rejection. Standard calibration procedures are sometimes complex and lengthy but must be carried out in a methodical and standard manner. Personnel are not permitted to deviate from explicit instructions in any manner, nor modify the procedure, nor substitute alternative equipment.
Employability Skills This unit contains employability skills.
Learning Outcomes and Application This unit of competency is applicable to laboratory and calibration technicians who carry out testing and/or calibrations using standard calibration methods in National Association of Testing Authorities (NATA) accredited laboratories. They work under limited supervision and their results are interpreted and checked by the laboratory supervisor, quality officer or designated signatory.Industry representatives have provided case studies to illustrate the practical application of this unit of competency and to show its relevance in a workplace setting. These are found at the end of this unit of competency under the section This competency in practice'.
Duration and Setting X weeks, nominally xx hours, delivered in a classroom/online/blended learning setting.
Prerequisites/co-requisites
Competency Field
Development and validation strategy and guide for assessors and learners Student Learning Resources Handouts
Activities
Slides
PPT
Assessment 1 Assessment 2 Assessment 3 Assessment 4
Elements of Competency Performance Criteria              
Element: Receive and schedule inspector's class reference standards for calibration
  • Identify the level of verification required by the client
  • Evaluate and implement appropriate strategies where the standard's suitability for purpose does not meet client expectations
  • Enter details for the inspector's class reference standard into the organisation's information management system and apply appropriate tracking mechanisms
  • Process 'urgent' calibration requests according to the organisation's policy and procedures
  • Maintain confidentiality of all client and organisation data and information
  • Ensure that information provided to clients is accurate, relevant and authorised for release
  • Deal with customers politely, efficiently and in accordance with organisational policy and procedures
       
Element: Prepare for calibration
  • Identify and access the appropriate procedure for the calibration in accordance with organisational policy and procedures
  • Identify possible sources of measurement error during calibration and implement appropriate control strategies
  • Condition inspector's class reference standards and high order reference standards in accordance with calibration and organisational procedures where applicable
  • Identify hazards and use the specified personal protective equipment, safety equipment and procedures
  • Evaluate the suitability of high order reference standards and measuring equipment selected for the calibration against the organisation's specification requirements and calibration procedure
  • Document calibration status, report out-of-calibration test equipment/high order reference standards and quarantine where required
       
Element: Perform calibration
  • Assess the design and appearance of an inspector's class reference standard against prescribed stadards
  • Perform calibration without variance according to the documented procedure to ensure repeatability of measurement
  • Confirm readings are the result of a valid measurement and record data as required
  • Adjust inspector's class reference standard if applicable
       
Element: Analyse and report calibration results
  • Estimate and document uncertainty of measurement in accordance with organisation's policy and procedures, if required
  • Identify prescribed performance criteria for the inspector's class reference standard and evaluate against calibration results
  • Analyse calibration results to confirm they are within the maximum permissible variation and uncertainty for the scope of calibration
  • Analyse any variances from the performance criteria to identify isolated or systemic problems with the inspector's class reference standards or calibration procedure
  • Record the results of each test/calibration accurately, unambiguously and objectively
       
Element: Finalise calibration
  • Attach calibration labels, equipment stickers, quality control tags and tamper resistant seals as required by the organisation's procedures
  • Prepare and submit to the laboratory supervisor a final report on the calibration detailing procedure, traceability, results and all other required information
  • Store test equipment/high order reference standards and calibration records in accordance with organisational policy and procedures
  • Identify and report unserviceable equipment or high order reference standards to the laboratory supervisor
  • Clean equipment and high order reference standards in accordance with organisational policy and procedures
       


Evidence Required

List the assessment methods to be used and the context and resources required for assessment. Copy and paste the relevant sections from the evidence guide below and then re-write these in plain English.

The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.

Overview of assessment

Competency must be demonstrated in the ability to perform consistently at the required standard for any inspector's class reference standards listed in the Range Statement.

Critical aspects for assessment and evidence required to demonstrate competency in this unit

Assessors should ensure that candidates can:

identify, access and apply calibration procedures

identify and use high order reference standards of measurement

evaluate and adjust the impact of the operating environment on the results of the calibration

identify the scope of a calibration and compare results with expected outcomes

maintain the security and confidentiality of data in accordance with organisational and regulatory requirements

report results in the required formats and expected timeframe.

Context of and specific resources for assessment

This unit of competency is to be assessed in the workplace or simulated workplace environment.

This unit of competency may be assessed with:

MSATMREF301A Use and maintain reference standards.

Resources may include:

reference standards, balances, weighing instruments and test equipment

computer and relevant software and/or organisation information management system

National Measurement Institute laboratory operating procedures

relevant legislative and organisational procedures.

Method of assessment

The following assessment methods are suggested:

questions to assess understanding of relevant metrology/calibration terms, principles and procedures

review of calibration reports prepared by the candidate

feedback from supervisors and peers regarding the candidate's ability to verify inspector's class reference standards in accordance with legislative and organisational procedures

observation of the candidate calibrating inspector's class reference standards.

In all cases, practical assessment should be supported by questions to assess underpinning knowledge and those aspects of competency which are difficult to assess directly. Questioning techniques should suit the language and literacy levels of the candidate.

This competency in practice

Industry representatives have provided the case studies below to illustrate the practical application of this unit of competency and to show its relevance in a workplace setting.

A customer delivers a 200 L Inspectors Class 1 Volume measure for calibration. Personnel in the laboratory's item reception area log the job and the laboratory supervisor assigns it to a calibration technician. He/she reads the work order and retrieves the approved calibration procedure. The procedure requires the measure to be tested gravimetrically. The technician accesses and validates the test equipment and high order reference standards. The density of the town water supply is determined using a verified hydrometer. The measure is visually inspected for defects and contamination. The volume of the measure is determined three times by filling the measure with town water to the capacity mark, recording the temperature of the water and recording the mass of water. This data is used, in conjunction with the town water density (determined previously) and thermal appropriate expansion/buoyancy corrections, to calculate the actual volume of the measure. The technician notes that some values are outside the allowable tolerance and adjustments will have to be made. He/she takes another set of readings after making the necessary adjustments and records them on the report. The technician applies the required calibration marks to the measure, updates the database, produces a test report and places the item in the despatch area for inspection by the supervisor. The supervisor visually inspects the item and checks the calibration data on the report. The job has taken four hours to complete.


Submission Requirements

List each assessment task's title, type (eg project, observation/demonstration, essay, assignment, checklist) and due date here

Assessment task 1: [title]      Due date:

(add new lines for each of the assessment tasks)


Assessment Tasks

Copy and paste from the following data to produce each assessment task. Write these in plain English and spell out how, when and where the task is to be carried out, under what conditions, and what resources are needed. Include guidelines about how well the candidate has to perform a task for it to be judged satisfactory.

Required skills

accessing, interpreting and applying a range of documents for the verification of reference standards including:

national measurement legislation

National Measurement Institute laboratory operating procedures

National Measurement Institute monographs

accessing and interpreting Certificates of Verification for a range of higher order reference standards

maintaining very close attention to procedures, accuracy and precision of measurement to ensure integrity of test/calibration results (especially during lengthy tests)

examining each calibration step critically to ensure repeatability and validity of data

selecting, setting up, validating, using and maintaining a range of balances and reference standards

operatingtest equipment correctly and safely

applying all relevant procedures and regulatory requirements to ensure the quality and integrity of the services or data provided

conducting tests and recording results with close attention to detail and accuracy

performing calculations involving:

fractions, decimals, ratios, proportions and percentages

scientific notation, correct units and the correct number of significant figures

interpretation of statistical quantities, such as mean, median, mode, range, variance and standard deviation

recognising problems or departures in systems and documentation and initiating actions to prevent or minimise them

preparing test/calibration documentation that is accurate and complies with requirements

recognising and reporting opportunities for improvements to procedures

planning routine tasks

solving routine/expected problems

working safely which may include applying basic first aid

Required knowledge

understanding of the purpose of metrology and calibration, including common terminology, concepts, principles, procedures and applications

detailed knowledge of specific metrology terms and principles such as uncertainty, maximum permissible variations, traceability and legal requirements for traceability

NATA's and the National Measurement Institute's role in the measurement and testing system in Australia, measurement standards laboratories

requirements for the competence of testing and calibration laboratories (for example, AS ISO/IEC 17025) as they affect job role and responsibilities

national measurement legislation applicable to verification of inspector's class reference standards

selection and application of appropriate test methods and calibration procedures

hierarchy and appropriate selection of reference instruments

detailed knowledge of calibration procedures (equipment, measurement steps, test conditions, environmental impacts, calculations, uncertainty treatment) to give results in appropriate accuracy, precision and units

use of calibration and correction charts

methods for statistical analysis (means, ranges, standard deviations) and estimation of uncertainty of measurement (may include the use of software)

non-conformance/non-compliance procedures and protocols associated with equipment, reference material and calibration procedures

troubleshooting procedures for equipment and test methods

handling, transport, storage and operation of reference and working standards

laboratory environmental control requirements

organisation's policy and procedures for verifying inspector's class reference standards

lines of communication, reporting procedures and legislative requirements

relevant health, safety and environmental requirements safety principles and procedures relevant test environment, basic first aid and site safety induction if required

The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.

Appropriate documentation

Where reference is made to documentation, it is expected the latest version will be used.

Appropriate documentation may include:

high order reference standard Certificates of Verification

test methods, calibration procedures and monographs (validated and authorised)

organisational test reports

organisational procedures e.g. company quality assurance manual

National Measurement Institute laboratory operating procedures

National Measurement Act

occupational health and safety (OHS) regulations, guidelines and procedures

equipment manuals and warranty, supplier catalogues and handbooks

quality manuals, equipment and operating/technical manuals

enterprise recording and reporting procedures and standard operating procedures (SOPs)

Hazards

Hazards may include:

electric shock

disturbance or interruption of services

manual handling of heavy equipment boxes

Safety procedures

Safety procedures may include:

use of personal protective equipment, such as hearing protection, gloves, safety glasses and coveralls

ensuring access to service shut-off points

regular cleaning of equipment and work areas

Inspectors Class Reference standards

Inspectors Class Reference standards may include:

inspector's class of reference standards as defined in the National Measurement Regulations

Operating procedures

Operating procedures may include:

manufacturers' specifications

industry guidelines

Australian standards

procedures and guidelines based on national measurement legislation

Legislation

Legislation may include:

national measurement legislation

applicable Commonwealth, state and territory OHS legislation

OHS and environmental management requirements

OHS and environmental management requirements refer to:

all operations must comply with enterprise OHS and environmental management requirements, which may be imposed through state/territory or Federal legislation. These requirements must not be compromised at any time

where relevant, users should access and apply current industry understanding of infection control issued by the National Health and Medical Research Council and State and Territory Departments of Health

Operating environmental impacts

Operating environmental impacts may include:

vibration

wind

heat

dust

electromagnetic interference

out of level

liquid being measured

Records

Records may include:

test reports

safety procedures

a history of equipment calibration and test results

Standard calibrations

Standard calibrations may involve testing and/or calibrating the following equipment and reference materials using standard methods and procedures:

common types of test equipment such as balances, calipers, masses, micrometers, tape measures, rules, temperature (digital) indicating systems, thermometers, timing devices, weighing instruments and volume measures

Copy and paste from the following performance criteria to create an observation checklist for each task. When you have finished writing your assessment tool every one of these must have been addressed, preferably several times in a variety of contexts. To ensure this occurs download the assessment matrix for the unit; enter each assessment task as a column header and place check marks against each performance criteria that task addresses.

Observation Checklist

Tasks to be observed according to workplace/college/TAFE policy and procedures, relevant legislation and Codes of Practice Yes No Comments/feedback
Identify the level of verification required by the client 
Evaluate and implement appropriate strategies where the standard's suitability for purpose does not meet client expectations 
Enter details for the inspector's class reference standard into the organisation's information management system and apply appropriate tracking mechanisms 
Process 'urgent' calibration requests according to the organisation's policy and procedures 
Maintain confidentiality of all client and organisation data and information 
Ensure that information provided to clients is accurate, relevant and authorised for release 
Deal with customers politely, efficiently and in accordance with organisational policy and procedures 
Identify and access the appropriate procedure for the calibration in accordance with organisational policy and procedures 
Identify possible sources of measurement error during calibration and implement appropriate control strategies 
Condition inspector's class reference standards and high order reference standards in accordance with calibration and organisational procedures where applicable 
Identify hazards and use the specified personal protective equipment, safety equipment and procedures 
Evaluate the suitability of high order reference standards and measuring equipment selected for the calibration against the organisation's specification requirements and calibration procedure 
Document calibration status, report out-of-calibration test equipment/high order reference standards and quarantine where required 
Assess the design and appearance of an inspector's class reference standard against prescribed stadards 
Perform calibration without variance according to the documented procedure to ensure repeatability of measurement 
Confirm readings are the result of a valid measurement and record data as required 
Adjust inspector's class reference standard if applicable 
Estimate and document uncertainty of measurement in accordance with organisation's policy and procedures, if required 
Identify prescribed performance criteria for the inspector's class reference standard and evaluate against calibration results 
Analyse calibration results to confirm they are within the maximum permissible variation and uncertainty for the scope of calibration 
Analyse any variances from the performance criteria to identify isolated or systemic problems with the inspector's class reference standards or calibration procedure 
Record the results of each test/calibration accurately, unambiguously and objectively 
Attach calibration labels, equipment stickers, quality control tags and tamper resistant seals as required by the organisation's procedures 
Prepare and submit to the laboratory supervisor a final report on the calibration detailing procedure, traceability, results and all other required information 
Store test equipment/high order reference standards and calibration records in accordance with organisational policy and procedures 
Identify and report unserviceable equipment or high order reference standards to the laboratory supervisor 
Clean equipment and high order reference standards in accordance with organisational policy and procedures 

Forms

Assessment Cover Sheet

MSATMVER403A - Verify inspector's class reference standards
Assessment task 1: [title]

Student name:

Student ID:

I declare that the assessment tasks submitted for this unit are my own work.

Student signature:

Result: Competent Not yet competent

Feedback to student

 

 

 

 

 

 

 

 

Assessor name:

Signature:

Date:


Assessment Record Sheet

MSATMVER403A - Verify inspector's class reference standards

Student name:

Student ID:

Assessment task 1: [title] Result: Competent Not yet competent

(add lines for each task)

Feedback to student:

 

 

 

 

 

 

 

 

Overall assessment result: Competent Not yet competent

Assessor name:

Signature:

Date:

Student signature:

Date: