Unit of Competency Mapping – Information for Teachers/Assessors – Information for Learners

UEEEC0039 Mapping and Delivery Guide
Install and test microwave antennae and waveguides

Version 1.0
Issue Date: May 2024


Qualification -
Unit of Competency UEEEC0039 - Install and test microwave antennae and waveguides
Description
Employability Skills
Learning Outcomes and Application This unit involves the skills and knowledge required to install and test microwave antennae and waveguides.It includes preparing to install and test microwave antennae and waveguides, installing microwave antennae and waveguides, testing microwave antennae and waveguides, and reporting outcomes.Permits may be required for some work environments, such as confined spaces, working aloft, near live electrical apparatus and site rehabilitation.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Duration and Setting X weeks, nominally xx hours, delivered in a classroom/online/blended learning setting.

Assessors must hold credentials specified within the Standards for Registered Training Organisations current at the time of assessment.

Assessment must satisfy the Principles of Assessment and Rules of Evidence and all regulatory requirements included within the Standards for Registered Training Organisations current at the time of assessment.

Assessment must occur in suitable workplace operational situations where it is appropriate to do so; where this is not appropriate, assessment must occur in suitable simulated workplace operational situations that replicate workplace conditions.

Assessment processes and techniques must be appropriate to the language, literacy and numeracy requirements of the work being performed and the needs of the candidate.

Resources for assessment must include access to:

a range of relevant exercises, case studies and/or simulations

relevant and appropriate materials, tools, equipment and personal protective equipment (PPE) currently used in industry

resources that reflect current industry practices in relation to installing microwave and antennae and waveguides

applicable documentation, including workplace procedures, equipment specifications, regulations, codes of practice and operation manuals.

Prerequisites/co-requisites
Competency Field Electronics and Communications
Development and validation strategy and guide for assessors and learners Student Learning Resources Handouts
Activities
Slides
PPT
Assessment 1 Assessment 2 Assessment 3 Assessment 4
Elements of Competency Performance Criteria              
Element: Prepare to install and test microwave antennae and waveguides
  • Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for relevant work area are identified, obtained and applied
       
Element: Risk control measures are applied in accordance with workplace procedures prior to commencing work
       
Element: Risks/hazards are identified, assessed and reported to relevant person/s, and control measures implemented
       
Element: Nature and location of the work is obtained from relevant person/s to determine scope of work
       
Element: Instructions for coordinating work with others are obtained from relevant person/s and applied
       
Element: Materials required for the work are determined in accordance with workplace procedures
       
Element: Tools, equipment and testing devices required for work are obtained in accordance with workplace procedures and checked for correct operation and safety
       
Element: Install microwave antennae and waveguides
  • Workplace risk control measures and procedures are applied
       
Element: Circuits/components are checked and isolated, as required, in accordance with WHS/OHS requirements and workplace procedures
       
Element: Antennas are installed in specified locations and within limitations imposed by regulations
       
Element: Hardware and accessories are installed straight and square in the required locations and within acceptable tolerances
       
Element: Cables and conductors are terminated at accessories in accordance with relevant industry standards, manufacturer instructions and job specifications
       
Element: Unplanned events are referred to relevant person/s in accordance with workplace procedures
       
Element: Installation is conducted efficiently, without waste of materials, damage to apparatus circuits or the surrounding environment applying sustainable energy practices
       
Element: Test microwave antennae and waveguides and report
  • WHS/OHS work completion risk control measures and workplace procedures are followed
       
Element: Pre-commissioning adjustments are made to the installation and the system to optimise performance in accordance with system specifications
       
Element: Worksite is cleaned and made safe in accordance with workplace procedures
       
Element: Relevant person/s is notified of installation completion in accordance with workplace procedures
       


Evidence Required

List the assessment methods to be used and the context and resources required for assessment. Copy and paste the relevant sections from the evidence guide below and then re-write these in plain English.

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions on at least two separate occasions and include:

accurately installing and securing antenna, waveguide hardware and accessories

applying relevant risk identification, assessment, reporting and control requirements

applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including the use of risk control measures

applying sustainable energy principles and practices

coordinating work with relevant person/s

correctly terminating cable and conductors

dealing effectively with unplanned events

determining scope of work

identifying and accessing materials, tools, apparatus and testing devices

isolating circuits/components

pre-commission adjusting for optimum performance

reading and interpreting drawings of circuit arrangements and component locations.

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions and include knowledge of:

antenna and wave guide principles and components

electronic communications, microwave antennas and waveguide fundamentals

installation techniques for microwave communication systems

relevant industry standards, codes and regulations

relevant manufacturer specifications

relevant safe work method statements (SWMS)/job safety assessments or risk mitigation processes

relevant WHS/OHS legislated requirements

relevant workplace documentation

relevant workplace policies and procedures

setting up and testing techniques for microwave communication systems.


Submission Requirements

List each assessment task's title, type (eg project, observation/demonstration, essay, assignment, checklist) and due date here

Assessment task 1: [title]      Due date:

(add new lines for each of the assessment tasks)


Assessment Tasks

Copy and paste from the following data to produce each assessment task. Write these in plain English and spell out how, when and where the task is to be carried out, under what conditions, and what resources are needed. Include guidelines about how well the candidate has to perform a task for it to be judged satisfactory.

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEE Electrotechnology Training Package Companion Volume Implementation Guide.

Installing, connecting and adjusting any microwave antennae and waveguides must include at least the following:

antennas

rectangular sections

curved sections

T sections

joints and couplers

Copy and paste from the following performance criteria to create an observation checklist for each task. When you have finished writing your assessment tool every one of these must have been addressed, preferably several times in a variety of contexts. To ensure this occurs download the assessment matrix for the unit; enter each assessment task as a column header and place check marks against each performance criteria that task addresses.

Observation Checklist

Tasks to be observed according to workplace/college/TAFE policy and procedures, relevant legislation and Codes of Practice Yes No Comments/feedback
Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for relevant work area are identified, obtained and applied 
 
 
 
 
 
 
Workplace risk control measures and procedures are applied 
 
 
 
 
 
 
WHS/OHS work completion risk control measures and workplace procedures are followed 
 
 
 

Forms

Assessment Cover Sheet

UEEEC0039 - Install and test microwave antennae and waveguides
Assessment task 1: [title]

Student name:

Student ID:

I declare that the assessment tasks submitted for this unit are my own work.

Student signature:

Result: Competent Not yet competent

Feedback to student

 

 

 

 

 

 

 

 

Assessor name:

Signature:

Date:


Assessment Record Sheet

UEEEC0039 - Install and test microwave antennae and waveguides

Student name:

Student ID:

Assessment task 1: [title] Result: Competent Not yet competent

(add lines for each task)

Feedback to student:

 

 

 

 

 

 

 

 

Overall assessment result: Competent Not yet competent

Assessor name:

Signature:

Date:

Student signature:

Date: