Unit of Competency Mapping – Information for Teachers/Assessors – Information for Learners
UEEEL0080 Mapping and Delivery Guide
Plan and analyse wiring systems, circuits, control and protection for electrical installations
Version 1.0
Issue Date: May 2024
Qualification | - |
Unit of Competency | UEEEL0080 - Plan and analyse wiring systems, circuits, control and protection for electrical installations |
---|---|---|---|
Description | |||
Employability Skills | |||
Learning Outcomes and Application | |||
Duration and Setting | X weeks, nominally xx hours, delivered in a classroom/online/blended learning setting. |
||
Prerequisites/co-requisites | |||
Competency Field |
Development and validation strategy and guide for assessors and learners | Student Learning Resources | Handouts Activities |
Slides PPT |
Assessment 1 | Assessment 2 | Assessment 3 | Assessment 4 | |
---|---|---|---|---|---|---|---|---|
Elements of Competency | Performance Criteria | |||||||
Element: Prepare to plan and analyse wiring systems, circuits, control and protection |
| |||||||
Element: Load requirements for individual current using equipment are determined from job specifications and/or consultation with appropriate people | ||||||||
Element: Cable routes, the route lengths of cable, and the conditions in which the wiring system is to operate is determined from job specifications or from consultation with appropriate people | ||||||||
Element: Evaluate and plan electrical circuits, control and protection |
| |||||||
Element: Earthing is planned to comply with the multiple earthed neutral (MEN) system requirements | ||||||||
Element: Protective devices are selected to meet the required switching and tripping currents, coordination and discrimination for overload and short circuit protection in accordance with relevant industry technical standards | ||||||||
Element: Residual current devices (RCDs) are planned to meet the required circuit switching and tripping currents, in accordance with relevant industry technical standards | ||||||||
Element: Switchgear/control gear is planned to meet current and voltage requirements and confirmed suitable for environmental conditions (ingress protection (IP) ratings) and functional requirements | ||||||||
Element: Switchboards are planned to accommodate control and protective devices, links, safety services and other distributor equipment in accordance with relevant industry technical standards | ||||||||
Element: Plan wiring systems and cables for general electrical installations |
| |||||||
Element: Cable conductor sizes are planned to meet current carrying capacity requirements and voltage drop and earth fault loop impedance limitations in accordance with relevant industry standards | ||||||||
Element: Circuit protective devices are planned to meet requirements for co-ordination with conductor current carrying capacity in accordance with relevant industry standards | ||||||||
Element: Earthing system components are planned to meet multiple earthed neutral (MEN) system in accordance with relevant industry standards | ||||||||
Element: Document electrical installation wiring systems, circuits, control and protection |
| |||||||
Element: Manufacturer data is referenced in planning of equipment to ensure materials comply with safety requirements and relevant industry standards | ||||||||
Element: Electrical installation arrangement and specifications for all items are documented |