Unit of Competency Mapping – Information for Teachers/Assessors – Information for Learners
UEENEEJ118A Mapping and Delivery Guide
Resolve problems in post mix refrigeration systems
Version 1.0
Issue Date: April 2024
Qualification | - |
Unit of Competency | UEENEEJ118A - Resolve problems in post mix refrigeration systems |
---|---|---|---|
Description | 1) 1.1) This unit covers resolving problems in post mix refrigeration systems. It encompasses working safely and to standards, applying knowledge of the components and operation of post mix refrigeration systems, using effective problem resolving techniques and documenting solutions. | ||
Employability Skills | 3)This unit contains Employability SkillsThe required outcomes described in this unit of competency contain applicable facets of Employability Skills. The Employability Skills Summary of the qualification in which this unit of competency is packaged will assist in identifying Employability Skill requirements. | ||
Learning Outcomes and Application | 4) This unit is intended to augment previously acquired competencies. It is suitable for employment-based programs under an approved contract of training. | ||
Duration and Setting | X weeks, nominally xx hours, delivered in a classroom/online/blended learning setting. |
||
Prerequisites/co-requisites | Prerequisite Unit(s)2) 2.1) CompetenciesGranting competency in this unit shall be made only after competency in the following unit(s) has/have been confirmed.UEENEEJ111A Diagnose and rectify faults in air conditioning and refrigeration systems and componentsUEENEEJ113A Commission air conditioning and refrigeration systemsUEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplaceUEENEEE102A Fabricate, assemble and dismantle utilities industry componentsUEENEEE003B Solve problems in extra-low voltage single path circuitsUEENEEE105A Fix and secure electrotechnology equipmentUEENEEE107A Use drawings, diagrams, schedules, standards, codes and specificationsUEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology workUEENEEJ102A Prepare and connect refrigerant tubing and fittingsUEENEEJ103A Establish the basic operating conditions of vapour compression systemsUEENEEJ104A Establish the basic operating conditions of air conditioning systemsUEENEEJ106A Install refrigerant pipe work, flow controls and accessoriesUEENEEJ107A Install air conditioning and refrigeration systems, major components and associated equipmentUEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerantsUEENEEJ110A Select refrigerant piping, accessories and associated controlsUEENEEJ153A Find and rectify faults motors and associated controls in refrigeration and air conditioning systemsUEENEEJ170A Diagnose and rectify faults in air conditioning and refrigeration control systemsUEENEEJ194A Solve problems in low voltage refrigeration circuitsUEENEEP012A Disconnect / reconnect composite appliances connected to low voltage installation wiringUEENEEP017A Locate and rectify faults in low voltage composite appliances using set proceduresorUEENEEJ155A Service refrigeration appliancesUEENEEJ154A Find and rectify faults in appliance control systems and devicesUEENEEJ162A Recover, pressure test, evacuate, charge and leak test refrigerants appliancesUEENEEJ102A Prepare and connect refrigerant tubing and fittingsUEENEEJ195A Establish the basic operating conditions of vapour compression systems - appliancesANDUEENEEG006A Solve problems in single and three phase low voltage machinesUEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplaceUEENEEE102A Fabricate, assemble and dismantle utilities industry componentsUEENEEE104A Solve problems in d.c. circuitsUEENEEE105A Fix and secure electrotechnology equipmentUEENEEE107A Use drawings, diagrams, schedules, standards, codes and specificationsUEENEEG101A Solve problems in electromagnetic devices and related circuitsUEENEEG102A Solve problems in low voltage a.c. circuitsUEENEEG106A Terminate cables, cords and accessories for low voltage circuitsorUEENEEJ155A Service refrigeration appliancesUEENEEJ153A Find and rectify faults motors and associated controls in refrigeration and air conditioning systemsUEENEEE107A Use drawings, diagrams, schedules, standards, codes and specificationsUEENEEJ103A Establish the basic operating conditions of vapour compression systemsUEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerantsUEENEEJ194A Solve problems in low voltage refrigeration circuitsUEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplaceUEENEEE003B Solve problems in extra-low voltage single path circuits | ||
Competency Field | 2.2) Literacy and numeracy skillsParticipants are best equipped to achieve competency in this unit if they have reading, writing and numeracy skills indicated by the following scales. Description of each scale is given in Volume 2, Part 3 'Literacy and Numeracy' Reading 3 Writing 3 Numeracy 3 |
Development and validation strategy and guide for assessors and learners | Student Learning Resources | Handouts Activities |
Slides PPT |
Assessment 1 | Assessment 2 | Assessment 3 | Assessment 4 | |
---|---|---|---|---|---|---|---|---|
Elements of Competency | Performance Criteria | |||||||
Element: Prepare to resolve problems in post mix refrigeration systems. |
| |||||||
Element: Resolve problems in post mix refrigeration systems |
| |||||||
Element: Note: Examples of information needed to resolve problems are system specifications, as-installed drawings, maintenance and service records and measured and calculated values of component operating parameters. |
| |||||||
Element: Complete work and document problem resolving activities. |
|