Unit of Competency Mapping – Information for Teachers/Assessors – Information for Learners

UEERA0007 Mapping and Delivery Guide
Apply safety awareness and legal requirements for flammable refrigerants

Version 1.0
Issue Date: May 2024


Qualification -
Unit of Competency UEERA0007 - Apply safety awareness and legal requirements for flammable refrigerants
Description
Employability Skills
Learning Outcomes and Application This unit involves the skills and knowledge required to apply safety awareness and legislative requirements for Class A2, A2L and A3 flammable refrigerants.It includes applying safety and relevant legislation to safely handle and store flammable refrigerants.Dangerous goods and ozone protection, work health and safety (WHS)/occupational health and safety (OHS), and synthetic greenhouse gas management legislative requirements apply to this unit.The skills and knowledgein this unit will be applied by those managing, supervising or working in or near a location that contains refrigeration or air conditioning equipment usingflammable refrigerant. These could include managers, supervisors, maintenance staff, cleaners, employees and refrigeration and air conditioning technicians
Duration and Setting X weeks, nominally xx hours, delivered in a classroom/online/blended learning setting.

Assessors must hold credentials specified within the Standards for Registered Training Organisations current at the time of assessment.

Assessment must satisfy the Principles of Assessment and Rules of Evidence and all regulatory requirements included within the Standards for Registered Training Organisations current at the time of assessment.

Assessment must occur in suitable workplace operational situations where it is appropriate to do so; where this is not appropriate, assessment must occur in simulated suitable workplace operational situations that replicate workplace conditions.

Assessment processes and techniques must be appropriate to the language, literacy and numeracy requirements of the work being performed and the needs of the candidate.

Resources for assessment must include access to:

a range of relevant exercises, case studies and/or simulations

relevant and appropriate materials, tools, facilities and equipment currently used in industry

applicable documentation, including workplace procedures, equipment specifications, regulations, codes of practice and operation manuals.

Prerequisites/co-requisites
Competency Field Refrigeration and air-conditioning
Development and validation strategy and guide for assessors and learners Student Learning Resources Handouts
Activities
Slides
PPT
Assessment 1 Assessment 2 Assessment 3 Assessment 4
Elements of Competency Performance Criteria              
Element: Prepare to work with flammable refrigerants
  • WHS/OHS requirements, legislative requirements and workplace procedures for a given work area are identified, obtained and applied
       
Element: Work area access permits are obtained from relevant person/s in accordance with workplace procedures
       
Element: Preparations for electrical and non-electrical isolation to prevent hazards from loss of machine/system/process control are conducted in accordance with WHS/OHS and workplace procedures
       
Element: Tools and equipment required for work are checked for safety and correct functionality in accordance with workplace procedures and relevant industry standards
       
Element: Apply safe working practices to flammable refrigerants
  • WHS/OHS risk control measures, legislative requirements and workplace procedures for carrying out the work are followed
       
Element: Workplace procedures for dealing with accidents, fires and emergencies are followed in accordance with WHS/OHS, legislative requirements and workplace procedures
       
Element: Follow workplace procedures for hazard identification and risk control of flammable refrigerants
  • Hazards are identified and risk control measures implemented and monitored in consultation with relevant person/s
       
Element: Hazards in the work area are recognised and reported to relevant person/s in accordance with workplace procedures
       
Element: WHS/OHS records of incidents are completed in accordance with relevant industry standards and workplace procedures
       
Element: Workplace instructions and training are followed in accordance workplace procedures
       


Evidence Required

List the assessment methods to be used and the context and resources required for assessment. Copy and paste the relevant sections from the evidence guide below and then re-write these in plain English.

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions on at least two separate occasions and include:

applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including using risk control measures

applying safe working practices to safely handle and store flammable refrigerant cylinders

applying work procedures and instructions as they apply to risk control measures

dealing with accidents and emergencies within the scope of responsibility

dealing with unplanned events

following workplace procedures for hazard identification and risk control of flammable refrigerants

participating in consultation processes, identifying hazards and implementing and monitoring control measures

preparing to enter the workplace, including using work permits and clearances and isolation permissions

preparing to work with flammable refrigerants.

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions and include knowledge of:

emergency procedures and incident management requirements and procedures

first aid

problem-solving techniques

refrigerant disposal requirements

relevant acts, regulations, code of practice and industry standard requirements

relevant cylinders and storage requirements

relevant environmental issues

relevant flammable refrigerant types and applications

relevant manufacturer specifications

relevant safe work method statements (SWMS)/job safety assessments or risk mitigation processes

relevant WHS/OHS legislated requirements

relevant workplace documentation

relevant workplace policies and procedures

types of Class A2, A2L and A3 flammable refrigerants.


Submission Requirements

List each assessment task's title, type (eg project, observation/demonstration, essay, assignment, checklist) and due date here

Assessment task 1: [title]      Due date:

(add new lines for each of the assessment tasks)


Assessment Tasks

Copy and paste from the following data to produce each assessment task. Write these in plain English and spell out how, when and where the task is to be carried out, under what conditions, and what resources are needed. Include guidelines about how well the candidate has to perform a task for it to be judged satisfactory.

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEE Electrotechnology Training Package Companion Volume Implementation Guide.

Applying safety awareness and legal requirements for flammable refrigerants must include the following:

class A2, A2L and A3 refrigerants

safe handling, storage and transport of flammable refrigerant cylinders

labelling requirement for flammable refrigerant cylinders and systems containing flammable refrigerant

personal protective equipment (PPE) required for the safe handling of flammable refrigerant

Copy and paste from the following performance criteria to create an observation checklist for each task. When you have finished writing your assessment tool every one of these must have been addressed, preferably several times in a variety of contexts. To ensure this occurs download the assessment matrix for the unit; enter each assessment task as a column header and place check marks against each performance criteria that task addresses.

Observation Checklist

Tasks to be observed according to workplace/college/TAFE policy and procedures, relevant legislation and Codes of Practice Yes No Comments/feedback
WHS/OHS requirements, legislative requirements and workplace procedures for a given work area are identified, obtained and applied 
 
 
 
WHS/OHS risk control measures, legislative requirements and workplace procedures for carrying out the work are followed 
 
Hazards are identified and risk control measures implemented and monitored in consultation with relevant person/s 
 
 
 

Forms

Assessment Cover Sheet

UEERA0007 - Apply safety awareness and legal requirements for flammable refrigerants
Assessment task 1: [title]

Student name:

Student ID:

I declare that the assessment tasks submitted for this unit are my own work.

Student signature:

Result: Competent Not yet competent

Feedback to student

 

 

 

 

 

 

 

 

Assessor name:

Signature:

Date:


Assessment Record Sheet

UEERA0007 - Apply safety awareness and legal requirements for flammable refrigerants

Student name:

Student ID:

Assessment task 1: [title] Result: Competent Not yet competent

(add lines for each task)

Feedback to student:

 

 

 

 

 

 

 

 

Overall assessment result: Competent Not yet competent

Assessor name:

Signature:

Date:

Student signature:

Date: