Employability Skills
Learning Outcomes and Application This unit involves the skills and knowledge required to establish the operating condition of a vapour compression system in a self-contained refrigerated appliance.Competency in this unit requires the ability to work safely; prepare for and establish operational conditions of vapour compression systems, including determining refrigerant pressures and relevant air temperatures using measurement and calculation methods; as well as completing all required documentation.To undertake this unit, the learner must have a Trainee Refrigerant Handling Licence as it includes work on refrigeration and air conditioning equipment that carries the risk of a fluorocarbon refrigerant being emitted.The skills and knowledge described in this unit may require a national Refrigerant Handling Licence as it includes work on refrigeration and air conditioning equipment that carries the risk of a fluorocarbon refrigerant being emitted while decanting the refrigerant or manufacturing, installing, commissioning, servicing, maintaining or decommissioning refrigeration and air conditioning equipment.The skills and knowledge described in this unit may, in some jurisdictions, also require a licence or permit to practice in the workplace subject to regulations for undertaking refrigeration and air conditioning work. Practice in the workplace and during training is also subject to work health and safety (WHS)/occupational health and safety (OHS) regulations.
Duration and Setting X weeks, nominally xx hours, delivered in a classroom/online/blended learning setting.

Assessors must hold credentials specified within the Standards for Registered Training Organisations current at the time of assessment.

Assessment must satisfy the Principles of Assessment and Rules of Evidence and all regulatory requirements included within the Standards for Registered Training Organisations current at the time of assessment.

Assessment must occur in workplace operational situations where it is appropriate to do so; where this is not appropriate, assessment must occur in simulated workplace operational situations that replicate workplace conditions.

Assessment processes and techniques must be appropriate to the language, literacy and numeracy requirements of the work being performed and the needs of the candidate.

Resources for assessment must include access to:

a range of relevant exercises, case studies and/or other simulations

relevant and appropriate materials, tools, equipment and personal protective equipment (PPE) currently used in industry

applicable documentation, including workplace procedures, industry standards, equipment specifications, regulations, codes of practice and operation manuals.

Prerequisites/co-requisites
Competency Field Refrigeration and air-conditioning
Development and validation strategy and guide for assessors and learners Student Learning Resources Handouts
Activities
Slides
PPT
Assessment 1 Assessment 2 Assessment 3 Assessment 4
Elements of Competency Performance Criteria              
Element: Prepare to determine operating conditions of vapour compression system
  • WHS/OHS hazards, risk control methods, relevant standards, codes and legislation are obtained and applied in accordance with workplace procedures
       
Element: Safety hazards, which have not previously been identified are reported in accordance with workplace procedures, and advice on risk control measures is sought from supervisor
       
Element: Details on work are obtained from documentation and/or from supervisor to establish the scope of work to be completed
       
Element: Advice is sought from supervisor, as required, to ensure work is coordinated with others
       
Element: Sources of materials required for work are identified and accessed in accordance with workplace procedures
       
Element: Tools, equipment and testing devices to establish the operating conditions of appliance's vapour compression system are obtained and checked for operational safety
       
Element: Determine operating condition of a vapour compression system
  • Measuring systems operating parameters are used in accordance with workplace procedures and WHS/OHS requirements
       
Element: Appliance vapour compression system is checked and isolated, where necessary, in accordance with workplace procedures and WHS/OHS requirements
       
Element: Actual and specified range of operating conditions of vapour compression system is established from measured and calculated values in accordance with workplace procedures
       
Element: Unplanned situations are responded to in accordance with workplace procedures and discussed with relevant person/supervisor in a manner that minimises risk to personnel and equipment
       
Element: Operating conditions of vapour compression system are determined without damage to appliance, circuits, the surrounding environment and/or services using relevant sustainable energy practices in accordance with workplace procedures
       
Element: Complete work and report activities
  • Worksite and equipment are cleaned and made safe in accordance with workplace procedures
       
Element: Operating condition of a vapour compression system is documented in accordance with workplace procedures, including identification of any parameter that is not within the specified range for the system
       
Element: Supervisor is notified of completion of work in accordance with workplace procedures
       


Evidence Required

List the assessment methods to be used and the context and resources required for assessment. Copy and paste the relevant sections from the evidence guide below and then re-write these in plain English.

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions on at least two separate occasions and include:

applying legislation, industry standards, codes of practice and regulations

applying relevant work, health and safety (WHS)/occupational health and safety (OHS) requirements, including

applying risk control measures

identifying hazards

implementing safe working practices

completing work and reporting requirements

determining operating conditions of appliance vapour compression systems, including:

selecting and using appropriate measuring devices

recording measurements

using calculation methods

identifying conditions of refrigerant at various locations in appliance vapour compression system

documenting operating conditions

dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment

using manufacturer specifications.

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions and include knowledge of:

operating conditions of vapour compression systems used in refrigerated appliances, including:

domestic refrigeration

vapour compression system

heat

temperature and relative humidity

sensible and latent heat

pressure

refrigerant conditions

vapour compression cycle

leak detectors

service gauges

refrigeration compressors

condensers and related components

evaporators and related components

common refrigerant metering devices

basic operating conditions

relevant legislation, industry standards, codes of practice and regulations

relevant manufacturer specifications

relevant risk mitigation processes, including:

safe working practices

potential hazards

risk control measures

relevant WHS/OHS legislated requirements

relevant workplace documentation

relevant workplace policies and procedures.


Submission Requirements

List each assessment task's title, type (eg project, observation/demonstration, essay, assignment, checklist) and due date here

Assessment task 1: [title]      Due date:

(add new lines for each of the assessment tasks)


Assessment Tasks

Copy and paste from the following data to produce each assessment task. Write these in plain English and spell out how, when and where the task is to be carried out, under what conditions, and what resources are needed. Include guidelines about how well the candidate has to perform a task for it to be judged satisfactory.

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEE Electrotechnology Training Package Companion Volume Implementation Guide.

Determining operating conditions of a vapour compression system must include the following:

suction and discharge pressures

ambient, evaporator and condensing temperatures

evaporator and condenser temperature difference

Copy and paste from the following performance criteria to create an observation checklist for each task. When you have finished writing your assessment tool every one of these must have been addressed, preferably several times in a variety of contexts. To ensure this occurs download the assessment matrix for the unit; enter each assessment task as a column header and place check marks against each performance criteria that task addresses.

Observation Checklist

Tasks to be observed according to workplace/college/TAFE policy and procedures, relevant legislation and Codes of Practice Yes No Comments/feedback
WHS/OHS hazards, risk control methods, relevant standards, codes and legislation are obtained and applied in accordance with workplace procedures 
 
 
 
 
 
Measuring systems operating parameters are used in accordance with workplace procedures and WHS/OHS requirements 
 
 
 
 
Worksite and equipment are cleaned and made safe in accordance with workplace procedures 
 
 

Forms

Assessment Cover Sheet

UEERA0037 - Establish the basic operating conditions of vapour compression systems - appliances
Assessment task 1: [title]

Student name:

Student ID:

I declare that the assessment tasks submitted for this unit are my own work.

Student signature:

Result: Competent Not yet competent

Feedback to student

 

 

 

 

 

 

 

 

Assessor name:

Signature:

Date:


Assessment Record Sheet

UEERA0037 - Establish the basic operating conditions of vapour compression systems - appliances

Student name:

Student ID:

Assessment task 1: [title] Result: Competent Not yet competent

(add lines for each task)

Feedback to student:

 

 

 

 

 

 

 

 

Overall assessment result: Competent Not yet competent

Assessor name:

Signature:

Date:

Student signature:

Date: