Unit of Competency Mapping – Information for Teachers/Assessors – Information for Learners
UEERE0035 Mapping and Delivery Guide
Install ELV stand-alone photovoltaic power systems
Version 1.0
Issue Date: May 2024
Qualification | - |
Unit of Competency | UEERE0035 - Install ELV stand-alone photovoltaic power systems | |
---|---|---|---|---|
Description | ||||
Employability Skills | ||||
Learning Outcomes and Application | This unit involves the skills and knowledge required to install extra-low voltage (ELV) stand-alone photovoltaic (PV) power systems.It includes preparing to install ELV stand-alone PV power apparatus and systems, installing ELV stand-alone PV power apparatus and system, completing installation and reporting installation activities.No licensing, legislative or certification requirements apply to this unit at the time of publication. | |||
Duration and Setting | X weeks, nominally xx hours, delivered in a classroom/online/blended learning setting.
|
|||
Prerequisites/co-requisites | ||||
Competency Field | Renewable Energy |
Development and validation strategy and guide for assessors and learners | Student Learning Resources | Handouts Activities |
Slides PPT |
Assessment 1 | Assessment 2 | Assessment 3 | Assessment 4 | |
---|---|---|---|---|---|---|---|---|
Elements of Competency | Performance Criteria | |||||||
Element: Prepare to install ELV stand-alone PV power apparatus and systems |
| |||||||
Element: WHS/OHS hazards are identified, risks assessed, reported to relevant person/s and workplace procedures for risk control measures applied in preparation for work | ||||||||
Element: System installation is planned in consultation with others impacted by the work and sequenced appropriately | ||||||||
Element: Nature and location of the work are determined from documentation or relevant person/s to determine the scope of work | ||||||||
Element: Sitting limitations and customer system requirements are identified through consultation with relevant person/s | ||||||||
Element: Energy demand is assessed and recommendations made to the customer for energy efficiency improvements, as necessary | ||||||||
Element: Suitable system components are specified and selected in accordance with workplace procedures | ||||||||
Element: Location of system components is planned within the constraints of the building structure and regulations | ||||||||
Element: Instructions for coordinating work with others is obtained from relevant person/s and applied | ||||||||
Element: Materials and components required are obtained, pre-assembled, where necessary, and checked against job requirements in accordance with workplace procedures | ||||||||
Element: Materials and components are prepared for transport to the site and transport is arranged in accordance with workplace procedures | ||||||||
Element: Tools, equipment and testing devices required are obtained in accordance with workplace procedures and checked for correct operation and safety | ||||||||
Element: Preparatory work is checked to ensure no unnecessary damage has occurred and complies with requirements | ||||||||
Element: Install ELV stand-alone PV power apparatus and systems |
| |||||||
Element: Need to test or measure live electrical work is determined in accordance with WHS/OHS requirements and conducted in accordance with workplace procedures | ||||||||
Element: Circuits/machines/plant are isolated in accordance with WHS/OHS requirements and workplace procedures | ||||||||
Element: System components are installed in compliance with technical industry standards, job specifications and requirements, and with sufficient access to enable terminations, adjustment and maintenance | ||||||||
Element: Wiring is terminated at components and associated equipment in accordance with manufacturer specifications and functional and regulatory requirements | ||||||||
Element: Unplanned situations are discussed with relevant person/s and responded to in accordance with workplace procedures in a manner that minimises risk to personnel and equipment | ||||||||
Element: Checks of installed apparatus quality are conducted in accordance with workplace procedures | ||||||||
Element: System installation is conducted minimising waste of materials, damage to apparatus, circuits, the surrounding environment and services using sustainable energy principles | ||||||||
Element: Complete installation and report installation activities |
| |||||||
Element: Final checks are conducted to confirm installed apparatus conforms to requirements | ||||||||
Element: System operation is tested and installation verified as compliant with standards and work specifications | ||||||||
Element: ‘As-installed’ apparatus and associated equipment are documented and relevant person/s notified in accordance with workplace procedures | ||||||||
Element: Customer is informed of system operation, routine maintenance and limitations | ||||||||
Element: Documentation required by standards or job specifications is provided to the customer |