Application
This unit describes the performance outcomes required to retrofit and modify air conditioning systems, including heating, ventilation and air conditioning (HVAC) systems, fitted to a range of vehicles and machinery. It involves preparing for the task, selecting the correct de-gas procedure, carrying out the retrofit and modification procedures, performing post-modification testing, and completing workplace processes and documentation.
Air conditioning systems may contain a mixture of both natural and flammable synthetic refrigerants that are difficult to accurately identify and safely recover. To minimise the possibility of ignition, the procedures and equipment used when recovering refrigerants must be those required for flammable refrigerants.
It applies to those working in the automotive service and repair industry. Automotive air conditioners, including HVAC systems, include those in agricultural machinery, heavy commercial vehicles, light vehicles or mobile plant machinery.
Licensing requirements apply to this unit. Users are advised to check with relevant regulatory authority. An Australian Refrigeration Council accredited (ARCtick) Refrigerant Handling licence is required for those carrying out this work.
Elements and Performance Criteria
Elements Elements describe the essential outcomes. | Performance Criteria Performance criteria describe the performance needed to demonstrate achievement of the element. Where bold and italicised text is used, further information is detailed in the range of conditions section. |
1. Prepare to retrofit system | 1.1 Job requirements are determined from workplace instructions 1.2 Retrofit information, manufacturer specifications, and relevant code of practice are accessed and interpreted 1.3 Type of refrigerant is determined according to workplace procedures and safety and environmental requirements 1.4 Retrofit options are analysed and those most appropriate to the circumstances are selected 1.5 Hazards associated with the work are identified and risks are managed 1.6 Retrofit tools and equipment are selected and checked for serviceability |
2. De-gas system | 2.1 System de-gas procedures are carried out according to manufacturer specifications, workplace procedures, and safety and environmental requirements, and without causing damage to components or system 2.2 Refrigerant is recovered into appropriate refrigerant recovery cylinder for the refrigerant type 2.3 Oil recovered is measured to determine replacement volume 2.4 System is evacuated according to manufacturer specifications, workplace procedures, and safety and environmental requirements |
3. Retrofit system | 3.1 Technical information relating to vehicle or machinery being retrofitted is accessed and interpreted 3.2 Air conditioning retrofit modification procedures are carried out according to manufacturer specifications, workplace procedures, and safety and environmental requirements 3.3 System is pressure tested for leaks before being re-gassed according to manufacturer specifications, workplace procedures, and safety and environmental requirements 3.4 System is re-gassed with appropriate refrigerant gas and lubricating oil according to manufacturer specifications and workplace procedures 3.5 Post-modification testing is carried out according to workplace procedures and test results are checked to confirm system performance is operating to manufacturer specifications, reported pre-modification issue has been resolved, and no other faults are present |
4. Complete work processes | 4.1 Final inspection is made to ensure work is to workplace expectations and the vehicle or machinery is presented ready for use 4.2 Work area is cleaned, waste and non-recyclable materials are disposed of, and recyclable material is collected 4.3 Tools and equipment are checked and stored and any faulty electrical equipment is identified, tagged and isolated according to workplace procedures 4.4 Australian Refrigeration Council accredited (ARCtick)service decal sticker and other required workplace documentation are completed and processed according to workplace procedures |
Evidence of Performance
Before competency can be determined, individuals must demonstrate they can perform the following according to the standard defined in the unit’s elements, performance criteria, range of conditions and foundation skills:
retrofit and modify the air conditioning and HVAC systems of two different vehicles or machinery, in which the work must include changing the type of refrigerant.
Evidence of Knowledge
Individuals must be able to demonstrate knowledge of:
work health and safety (WHS) and occupational health and safety (OHS) requirements relating to retrofitting and modifying air conditioning and HVAC systems, including procedures for:
working with refrigerants at boiling point given risk of frostbite
working with system lubricants, including carcinogenic oils
identifying and handling flammable refrigerants, including hydrocarbon (HC) refrigerants
selecting and using personal protective equipment (PPE)
identifying firefighting equipment
environmental requirements, including procedures for:
preventing loss of refrigerant to the atmosphere
handling materials and refrigerant recovery equipment
key requirements of Australian automotive code of practice: Control of refrigerant gases during manufacture, installation, servicing or de-commissioning of motor vehicle air conditioners
application, purpose and operation of air conditioning and HVAC systems and components, including:
high pressure and low pressure sides of air conditioning systems
compressors, including:
piston, scroll and rotary vane compressors
electric compressors
variable displacement compressors
clutchless compressors electromagnetic clutches
condensers
receiver-dryers, including filters and desiccants
expansion valves, including capillary tubes
evaporators
thermostats
refrigerants, including R12, R134a, R1234yf, R290 and R600a blends
compressor oils
air conditioner and heating controls, including levers and ducting
air conditioner and heating electrical circuits and sensors, including:
high and low pressure switches
pressure relief valves
temperature sensors
climate control systems
procedures for retrofitting and modifying air conditioning and HVAC systems, including:
determining original system fitted to vehicle, including refrigerant and oil type and types of components
determining appropriate retrofit and modification options, including:
determining required system performance output
component replacement, including O rings and seals
refrigerant and oil selection
procedures for removing and replacing system components
procedures for changing system refrigerant, including:
changing refrigerant gas from R12 to R134a:
receiver dryer filter replacement
change system fittings for manifold gauge attachment
change oil type
changing refrigerant gas from R134a to R1234yf:
change refrigerant recharging ports
change system fittings for manifold gauge attachment
changing refrigerant gas from R134a to blends of R290 and R600a:
change refrigerant re-charging ports
change system fittings for manifold gauge attachment
procedures for recovering automotive refrigerant, including:
testing refrigerant to determine its type
connecting manifold and gauge set and recovery unit, including types and location of service ports
identifying recovery cylinder appropriate to the refrigerant
operating recovery unit, including weighing recovery cylinder before after recovery
disconnecting and storing recovery unit and cylinder
procedures for re-gassing air conditioning and HVAC systems, including:
testing system for leaks using vacuum and pressure testing
using manifold gauges to charge system
post-retrofit testing procedures for air conditioning and HVAC systems, including procedures for checking for:
refrigerant leaks
heater core and system water coolant leaks
static and dynamic performance tests of air conditioning and HVAC systems, including checking:
ambient temperature
vent temperature
condenser and suction line temperature
procedures for completing workplace documentation, including ARCtick service decal sticker.
Assessment Conditions
Assessors must satisfy NVR/AQTF assessor requirements and hold an Australian Refrigerant Council (ARC) Refrigerant Handling licence.
Competency is to be assessed in the workplace or a simulated environment that accurately reflects performance in a real workplace setting.
Assessment must include direct observation of tasks.
Where assessment of competency includes third-party evidence, individuals must provide evidence that links them to the air conditioning and HVAC systems that they have retrofitted and modified, e.g. repair orders.
Assessors must verify performance evidence through questioning on skills and knowledge to ensure correct interpretation and application.
The following resources must be made available:
automotive repair workplace or simulated workplace
workplace instructions
vehicle or machinery air conditioning and HVAC system manufacturer specifications
Australian automotive code of practice: Control of refrigerant gases during manufacture, installation, servicing or de-commissioning of motor vehicle air conditioners
two different vehicles or machinery with air conditioning and HVAC systems requiring retrofitting and modification
retrofit, modification and testing equipment for air conditioning and HVAC systems, including:
manifold and gauge set
recovery unit
vacuum pump
leak detector
refrigerant analyser.
Foundation Skills
This section describes those language, literacy, numeracy and employment skills that are essential to performance and are not explicit in the performance criteria.
Skills | Description |
Learning skills to: | locate appropriate sources of information efficiently. |
Reading skills to: | interpret text, symbols and diagrams relating to retrofit and modification information from manufacturer specifications, and workplace instructions and procedures interpret key requirements of Australian automotive code of practice relating to retrofitting and modifying air conditioning and HVAC systems. |
Writing skills to: | legibly and accurately fill out workplace documentation, including ARCtick stickers, when reporting test findings, making modification recommendations, and recording parts and material used. |
Oral communication skills to: | listen to workplace instructions and ask questions to clarify job requirements. |
Numeracy skills to: | match refrigerant types and identification numbers to workplace instructions, vehicle and component part lists, and code of practice requirements interpret weighting measurements, including tare and gross weights interpret readings on digital and analogue pressure gauges measure temperatures and pressures, and use basic mathematical operations, including addition and subtraction, to calculate deviations from manufacturer specifications. |
Planning and organising skills to: | plan own work requirements and prioritise actions to achieve required outcomes and ensure tasks are completed within workplace timeframes. |
Technology skills to: | use workplace technology and tools, such as refrigerant analyser, vacuum recovery equipment and manifold gauges. |
Range Statement
This section specifies work environments and conditions that may affect performance. Essential operating conditions that may be present (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) are included. Bold italicised wording, if used in the performance criteria, is detailed below.
Code of practice must include: | Australian automotive code of practice: Control of refrigerant gases during manufacture, installation, servicing or de-commissioning of motor vehicle air conditioners. |
Safety and environmental requirements must include: | work health and safety (WHS) and occupational health and safety (OHS) requirements, including procedures for: working with refrigerants at boiling point given risk of frostbite working with system lubricants, including carcinogenic oils identifying flammable refrigerants, including hydrocarbon (HC) refrigerants selecting and using personal protective equipment (PPE) identifying firefighting equipment environmental requirements, including procedures for: preventing loss of refrigerant to the atmosphere handling materials and refrigerant recovery equipment. |
Australian Refrigeration Council accredited (ARCtick) service decal sticker information must include: | name of the service organisation ARCtick business authority number quantity of refrigerant added refrigerant and oil type service date technician name and licence number. |
Sectors
Technical - Air Conditioning and HVAC
Competency Field
Electrical