Application
This unit supports the attainment of skills and knowledge required for competent workplace performance in leadlight and stained glass operations. The requirement to install heritage lead light and stained glass panels applies to an on site environment and involves application of skills and knowledge at an artisan level. These skills and knowledge are to be used within the scope of the individual's job and authority. |
Prerequisites
Nil | ||
Elements and Performance Criteria
ELEMENT | PERFORMANCE CRITERIA |
1. Identify and plan installation requirements | 1.1. Applicable OHS, legislative and organisational requirements relevant to lead light and stained glass operations are verified and complied with 1.2. Location of the lead light and stained glass panel to be installed is established confirmed and clarified with appropriate personnel 1.3. Installation sequence is identified and a work plan is developed 1.4. Tools and equipment required for the installation are identified 1.5. Approval of installation plan is obtained as required by agreed procedures |
2. Prepare for the installation | 2.1. Tools and equipment are positioned and checked prior to use to ensure that they are appropriate for the installation, serviceable and in a safe condition 2.2. Inspection of the opening where the panel is to be installed is conducted 2.3. Lead light and stained glass panel is inspected to ensure its integrity while being installed 2.4. Plans and other documents are positioned to allow for confirmation of the panel structure and placement 2.5. Photographs are taken of the panel for later reference |
3. Install the panel | 3.1. Panel is installed and placed in position 3.2. Supporting frames are removed from the panel 3.3. Panel structural supports are installed and checked 3.4. Structural damage is identified and noted |
4. Finalise and report on the installation | 4.1. Installed panel is inspected and damage resulting from the installation is identified and rectified 4.2. Tools and equipment are removed cleaned and stored appropriately 4.3. Removal area is cleaned and rubbish disposed of as appropriate 4.4. Installation report is prepared and provided as required |
Required Skills
|
Required skills |
collect, organise and understand materials technology and information related to heritage leadlight and stained glass communicate ideas and information to enable confirmation of work requirements and specifications, coordination of work with site supervisor, other workers and customers, and the reporting of work outcomes and problems maintain quality records related to heritage leadlight and stained glass work with others and in a team by recognising dependencies and using cooperative approaches to optimise work flow and productivity identify, anticipate and respond to faults in heritage leadlight and stained glass recognise and respond to circumstances outside instructions or personal competence plan and organise activities including the preparation and layout of own worksite and the obtaining and use of tools and materials to avoid any backtracking, work flow interruptions or wastage use mathematical ideas and techniques to correctly complete measurements, calculate area and volume, estimate work and material requirements clarify and confirm work instructions plan own work within the given task parameters accept responsibility for given tasks set, monitor and satisfy personal work goals satisfy the competency requirements for the job maintain current knowledge of tools and materials maintain current knowledge of heritage leadlight and stained glass seek learning opportunities use the workplace technology related to the installation of heritage leadlight and stained glass components, including computers, measuring devices and recording systems |
Required knowledge |
State or Territory OHS legislation, regulations, standards and codes of practice relevant to the full range of processes for lead light and stained glass operations lead light and stained glass panels construction and repair terminology and techniques the principles of the Burra Charter, the Australia ICOMOS Charter for Places of Cultural Significance organisational and site standards, requirements, policies and procedures for the installation of heritage lead light and stained glass panels types of glass and other materials, historically used in the lead light and stained glass industry, their characteristics, properties, uses and limitations heritage requirements specific to lead light and stained glass engineering aspect of supporting lead light and stained glass panels during the installation process established communication channels and protocols problem identification and resolution storage systems and labelling procedures for the recording, reporting and maintenance of workplace records and information appropriate mathematical procedures for estimation and measurement |
Evidence Required
The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package. | |
Critical aspects for assessment and evidence required to demonstrate competency in this unit | Read and interpret a work/job specification Identify and interpret heritage legislation as it applies to lead light and stained glass panels Identify historical lead light and stained glass panel construction methods Identify framing, structural and construction techniques relevant to lead light and stained glass panels Identify installation methodologies Install heritage lead light and stained glass panels Comply with legislation, regulations, standards, codes of practice and established safe practices and procedures for the removal of heritage lead light and stained glass panels Communicate effectively and work safely with others in the work area |
Context of, and specific resources for assessment | The application of competency is to be assessed in the workplace or realistically simulated workplace Assessment is to occur under standard and authorised work practices, safety requirements and environmental constraints Assessment of essential underpinning knowledge, other than confirmatory questions, will usually be conducted in an off-site context Assessment is to comply with relevant regulatory or Australian Standards requirements The following resources should be made available: workplace location or simulated workplace materials and equipment relevant to the installation of heritage lead light and stained glass panels following conservation work specifications and work instructions |
Method of assessment | Assessment must satisfy the endorsed assessment guidelines of the Furnishing Industry Training Package Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with application of underpinning knowledge Assessment methods must be by direct observation of tasks and include questioning on underpinning knowledge to ensure its correct interpretation and application Assessment may be applied under project related conditions (real or simulated) and require evidence of process Assessment must confirm a reasonable inference that competency is able not only to be satisfied under the particular circumstance, but is able to be transferred to other circumstances Assessment may be in conjunction with assessment of other units of competency |
Range Statement
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included. | |
OHS requirements | are to be in accordance with Commonwealth, State or Territory legislation and regulations, organisational safety policies and procedures. Requirements may include but not be limited to the use of personal protective equipment and clothing, fire fighting equipment, First Aid equipment, hazard and risk control and elimination of hazardous materials and substances, manual handling including lifting and carrying. |
Legislative requirements | are to be in accordance with applicable legislation from all levels of government that affect organisational operation. Requirements may include but not be limited to award and enterprise agreements, industrial relations, Australian Standards, confidentiality and privacy, OHS, the environment, equal opportunity, anti-discrimination, relevant industry codes of practice, duty of care and heritage. |
Organisational requirements | may include but not be limited to legal, organisational and site guidelines, policies and procedures relating to own role and responsibility, quality assurance, procedural manuals, quality and continuous improvement processes and standards, OHS, emergency and evacuation, ethical standards, recording and reporting, access and equity principles and practices, equipment use, maintenance and storage, environmental management (waste disposal, recycling and re-use guidelines) |
Appropriate personnel | may include but not be limited to clients, architects, engineers construction supervisors, members of heritage committees, government agencies other specialist artisans, such as stonemasons |
Tools and equipment | may include work benches, ladders and scaffolding, cameras, magnifying glasses, lights, cranes, forklifts and general hand tools |
Inspection | may include measuring to determine if the panel is the correct size and ensuring that the supporting infrastructure required for the panel is in place |
Plans and other documents | may include original architectural plans, historical documents and photographs, contemporary photographs, charcoal rubbings and sketches |
Installation | may include the requirement to dismantle the panel prior to installation to stop it from falling apart and assembling the panel in place |
Supporting frames | may include wooden or metal frames that support the lead light and stained glass panels during its transportation and installation |
Installation report | would be in a format required by the client and may include such aspects as the extent of any damage to the surrounding building or fixture, any damage to the panel and any recommendations as to future requirements |
Sectors
Unit sector | Lead Light and Stained Glass |
Employability Skills
This unit contains employability skills. |
Licensing Information
Not applicable.