UEEDV0001
Assemble and connect telecommunication frames and cabinets


Application

This unit involves the skills and knowledge required to assemble and connect telecommunication frames and cabinets.

It includes identifying, assembling, connecting and checking quality of assembled telecommunication frames and cabinets.

No licensing, legislative or certification requirements apply to this unit at the time of publication.


Elements and Performance Criteria

ELEMENTS

PERFORMANCE CRITERIA

Elements describe the essential outcomes.

Performance criteria describe the performance needed to demonstrate achievement of the element.

1

Identify telecommunication frame and cabinet

1.1

Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures are identified and applied

1.2

Hazards are identified, risks are assessed and control measures are implemented

1.3

Work instructions and relevant diagrams are identified and applied

1.4

Advice is sought from workplace supervisor to ensure work is coordinated with relevant person/s

1.5

Materials required for work are obtained in accordance with workplace procedures

1.6

Tools, equipment and testing devices required for work are obtained in accordance with workplace procedures and checked for correct operation and safety

2

Assemble and connect telecommunication frame and cabinet

2.1

WHS/OHS risk control workplace measures are followed

2.2

Equipment is checked and isolated in accordance with WHS/OHS requirements and workplace procedures

2.3

Frame/cabinet and communication components are fitted in accordance with work instructions, industry standards, manufacturer instructions and workplace procedures

2.4

Interconnections are made in accordance with workplace procedures

2.5

Installation and equipment are checked for compliance with relevant industry standards

2.6

Completed communication frames/cabinets are checked/tested against manufacturer instructions, industry standards and workplace procedures

2.7

Unplanned situations are responded to in accordance with workplace procedures and approval of authorised person/s

2.8

Work is performed using sustainable energy principles and practices without wasting materials, damaging apparatus, surrounding environments or services in accordance with workplace procedures

3

Check quality of assembled telecommunication frame and cabinet

3.1

WHS/OHS risk control measures for work completion are followed

3.2

Quality of assembled frame/cabinet is checked/tested against work instructions, industry standards, manufacturer instructions and workplace procedures

3.3

Appropriate solutions are used where corrective actions to assembled components are required in accordance with workplace procedures

3.4

Work report forms are completed and appropriate person/s notified in accordance with workplace procedures

Evidence of Performance

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria on at least two separate occasions and include:

applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including implementing risk control measures

applying sustainable energy principles and practices

checking and testing quality of assembled telecommunication frame and cabinet, including adhering to quality procedures

completing work report forms

dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment

determining and using appropriate solutions in accordance with workplace procedures

following assembly instructions

identifying, assembling and connecting telecommunication frame and cabinet

isolating in accordance with relevant industry standards

making connection without damaging apparatus

obtaining relevant equipment, tools, testing devices and materials

seeking advice from supervisor

using manufacturer instructions.


Evidence of Knowledge

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria and include knowledge of:

cabinet internal cable routing and management provisions

cabinet ventilation requirements

cabinet structure, including:

internal framework

cable entry

removable panels

multiple cabinets

doors, locks and hinges

mounting rails

access to equipment and cabling

earthing arrangements and methods

mounting requirements for components, including:

rack units

patch panels

routers

servers

communication cable and conductor terminations, including:

approved termination devices and sockets

special termination tools and their use

cable colour coding up to 100 pair indoor and outdoor cable

methods of terminating cables, including:

cables less than twenty pair

twenty pair cable and greater

structured cables

coaxial cables

optical fibre cables

termination safety practices

cable labelling devices, including quality checks and tests

component installation and interconnections

relevant job safety assessments or risk mitigation processes, including risk control measures

relevant manufacturer specifications and instructions

relevant tools, equipment and testing devices

relevant WHS/OHS legislated requirements

relevant workplace documentation and diagrams

relevant workplace policies and procedures

sustainable energy principles and practices

telecommunication cabinet assembly, cabling and terminations.


Assessment Conditions

Assessors must hold credentials specified within the Standards for Registered Training Organisations current at the time of assessment.

Assessment must satisfy the Principles of Assessment and Rules of Evidence and all regulatory requirements included within the Standards for Registered Training Organisations current at the time of assessment.

Assessment must occur in workplace operational situations where it is appropriate to do so; where this is not appropriate, assessment must occur in simulated workplace operational situations that replicate workplace conditions.

Assessment processes and techniques must be appropriate to the language, literacy and numeracy requirements of the work being performed and the needs of the candidate.

Resources for assessment must include access to:

a range of relevant exercises, case studies and/or other simulations

relevant and appropriate materials, tools, equipment and personal protective equipment (PPE) currently used in industry

applicable documentation, including workplace procedures, equipment specifications, regulations, codes of practice and operation manuals.


Foundation Skills

Foundation skills essential to performance are explicit in the performance criteria of this unit of competency.


Range Statement

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEE Electrotechnology Training Package Companion Volume Implementation Guide.


Sectors

Electrotechnology


Competency Field

Data and Voice