The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!
From the Wiki University
What evidence can you provide to prove your understanding of each of the following citeria?
Evaluate design parameters.
|
|
Fire and non fire-rated compartments of buildings are evaluated and the application of evaluation to hydraulic services is specified. Completed |
Evidence:
|
Design requirements are determined from plans, specifications and client briefs. Completed |
Evidence:
|
Cost-benefit analysis is conducted, comparing a range of pipe materials, system designs and penetration protection systems. Completed |
Evidence:
|
Statutory, regulatory, Australian and New Zealand standards and relevant building code requirements for the design of fire-compliant hydraulic services are interpreted and applied. Completed |
Evidence:
|
Manufacturer requirements and trade and technical manuals are interpreted and applied. Completed |
Evidence:
|
Additional research, including a desktop study, is conducted and performance requirements are established. Completed |
Evidence:
|
Plan and detail system components.
|
|
Layout of pipework systems and type and location of fire check collars are planned. Completed |
Evidence:
|
Approved fire-rated materials, penetration techniques, insulation and filler materials are specified to appropriate fire-resistance level. Completed |
Evidence:
|
Pipe fixings are designed for a range of applications. Completed |
Evidence:
|
Pipework for sprinklered and non-sprinklered areas is designed for a range of applications. Completed |
Evidence:
|
Installation requirements are specified. Completed |
Evidence:
|
Compliance inspection is conducted. Completed |
Evidence:
|
Design and size systems.
|
|
Fire-compliant hydraulic services are designed for a range of wide span and high-rise building applications. Completed |
Evidence:
|
Range of fire-compliant duct systems is designed using fire-rated building materials. Completed |
Evidence:
|
Hydraulic services using non fire-rated materials are designed to comply with building fire ratings. Completed |
Evidence:
|
Fire-compliant hydraulic distribution systems are designed and sized using computer software packages. Completed |
Evidence:
|
Prepare documentation.
|
|
Plans are prepared and detailed for a range of fire-compliant hydraulic services. Completed |
Evidence:
|
Specification for fire-compliant hydraulic services is prepared. Completed |
Evidence:
|
Compliance report is prepared. Completed |
Evidence:
|
Operation and maintenance manual is produced. Completed |
Evidence:
|