The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!
From the Wiki University
What evidence can you provide to prove your understanding of each of the following citeria?
Prepare for installation.
|
|
Installation information for domestic solid fuel burning appliances is interpreted and compliance requirements confirmed according to organisational, manufacturer and legislative requirements. Completed |
Evidence:
|
Installation permits are checked or obtained as necessary in consultation with client and local authority. Completed |
Evidence:
|
Installation sites are inspected and appliance installation locations confirmed as suitable or alternative locations negotiated with clients. Completed |
Evidence:
|
Location preparation work required by other contractors is arranged in consultation with client. Completed |
Evidence:
|
Heat sensitivities of building materials at appliance installation locations are confirmed, and heat protection strategies are confirmed with clients. Completed |
Evidence:
|
Tasks are planned and equipment and materials are gathered and checked according to organisational requirements. Completed |
Evidence:
|
Sustainability principles and concepts are identified for work preparation and application. Completed |
Evidence:
|
Install appliance.
|
|
Appliance location is measured and marked according to compliance requirements. Completed |
Evidence:
|
Floor protection material is measured and cut or made up and installed according to compliance requirements. Completed |
Evidence:
|
Appliance is positioned and clearance distances are checked to confirm compliance. Completed |
Evidence:
|
Appliance is installed according to compliance and organisational requirements. Completed |
Evidence:
|
Install flue.
|
|
Flue dimensions and components are checked and additional sections or components obtained as required to meet compliance requirements. Completed |
Evidence:
|
Locations and dimensions of ceiling and roof penetrations are calculated, measured, marked and checked according to compliance and organisational requirements. Completed |
Evidence:
|
Penetrations are made with minimal damage to host materials and according to specifications and organisational requirements. Completed |
Evidence:
|
Structural supports are installed according to plans and specifications. Completed |
Evidence:
|
Opening is prepared in compliance with specifications, manufacturer recommendations and regulations. Completed |
Evidence:
|
Flue and associated components are installed according to compliance and organisational requirements. Completed |
Evidence:
|
Flashings and sealants are applied to restore integrity of ceilings and roofs according to compliance and organisational requirements. Completed |
Evidence:
|
Penetration is performance tested to ensure correct fit of completed installation, and remedied as required. Completed |
Evidence:
|
Finalise installation.
|
|
Installed appliance and associated components are checked for complete and correct installation according to compliance and organisational requirements. Completed |
Evidence:
|
Installation site is restored and equipment is cleaned, checked and stored according to organisational requirements. Completed |
Evidence:
|
Operation of appliance is demonstrated to clients and factors affecting optimum performance are explained. Completed |
Evidence:
|
Conformance certificate is prepared and processed according to compliance and organisational requirements. Completed |
Evidence:
|