Evidence Guide: ICTTC136C - Install, maintain and modify customer premises communications cabling: ACMA Restricted Rule

Student: __________________________________________________

Signature: _________________________________________________

Tips for gathering evidence to demonstrate your skills

The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!

From the Wiki University

 

ICTTC136C - Install, maintain and modify customer premises communications cabling: ACMA Restricted Rule

What evidence can you provide to prove your understanding of each of the following citeria?

Work within the constraints imposed by customer premises

  1. Identify building infrastructure which places critical constraints on cabling
  2. Develop strategies to manage other infrastructure in relation to cabling
Identify building infrastructure which places critical constraints on cabling

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Develop strategies to manage other infrastructure in relation to cabling

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Manage Remote Power Feed

  1. Identify the risks posed by contact with Remote Power Feeding services
  2. Identify Remote Power Feeding services in a range of commonly encountered circumstances inside customer premises
Identify the risks posed by contact with Remote Power Feeding services

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Identify Remote Power Feeding services in a range of commonly encountered circumstances inside customer premises

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Install/alter cables and protective earth wires

  1. Cables/wires handled in accordance with manufacturer's application specifications including tension and bending stress requirements
  2. Sources of possible damage to cable/wires are identified and avoided including hot pipes, sharp edges and cable burn
  3. Sufficient excess is allowed at cable ends to facilitate termination
  4. Cable is placed and secured to maintain safety and interference segregation in accordance with legislative and industry standards
  5. Cable ties not tightened to the point of causing cable sheath damage or transmission impairment and trimmed flush to prevent risk of personal damage
  6. Cables installed underground shall meet minimum depth of cover and segregation from hazardous electrical and other services as per AS/ACIFS009:2006
  7. Aerial cables installed shall meet minimum clearance, segregation from hazardous electrical and other services and minimum height requirements as per AS/ACIFS009:2006
  8. In accordance with AS/ACIFS009:2006, overvoltage protection devices are fitted to all cable pairs where required to suppress voltage surges and protect from EPR hazards and the devices protectively earthed
  9. Earth wire insulation is protected against damage and protective earths segregated in accordance with relevant industry and legislative standards
Cables/wires handled in accordance with manufacturer's application specifications including tension and bending stress requirements

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Sources of possible damage to cable/wires are identified and avoided including hot pipes, sharp edges and cable burn

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Sufficient excess is allowed at cable ends to facilitate termination

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Cable is placed and secured to maintain safety and interference segregation in accordance with legislative and industry standards

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Cable ties not tightened to the point of causing cable sheath damage or transmission impairment and trimmed flush to prevent risk of personal damage

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Cables installed underground shall meet minimum depth of cover and segregation from hazardous electrical and other services as per AS/ACIFS009:2006

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Aerial cables installed shall meet minimum clearance, segregation from hazardous electrical and other services and minimum height requirements as per AS/ACIFS009:2006

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

In accordance with AS/ACIFS009:2006, overvoltage protection devices are fitted to all cable pairs where required to suppress voltage surges and protect from EPR hazards and the devices protectively earthed

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Earth wire insulation is protected against damage and protective earths segregated in accordance with relevant industry and legislative standards

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Terminate and test cables and earth wires

  1. Cable sheath removed to allow for correct termination length and without damage to underlying conductors and their insulation
  2. NTD terminating modules are installed in accordance to manufacturer's specifications and cable pairs neatly and sequentially fanned for termination
  3. Conductors are terminated in accordance with recommended colour code sequence using appropriate termination tools in the manufacturer's specified manner
  4. Cable shield (if applicable) is earthed to manufacturer's specifications and relevant industry codes of practice and AS/ACIFS009:2006
  5. Visual inspection is undertaken to confirm termination colour code sequence has been followed prior to end to end testing of wire and pair termination integrity
  6. Earth wires are terminated with connectors recommended by manufacturers in accordance with accepted industry codes of practice and AS/ACIFS009:2006
  7. Earth wire continuity is maintained through out and interface requirements with electrical systems are observed
  8. Earthing installation shall be tested for continuity, insulation resistance and conductive resistance as per accepted industry standards including AS/ACIFS009:2006
  9. Compatibility of alterations with existing systems is confirmed and new wok tested both in isolation and when integrated with existing systems
Cable sheath removed to allow for correct termination length and without damage to underlying conductors and their insulation

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

NTD terminating modules are installed in accordance to manufacturer's specifications and cable pairs neatly and sequentially fanned for termination

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Conductors are terminated in accordance with recommended colour code sequence using appropriate termination tools in the manufacturer's specified manner

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Cable shield (if applicable) is earthed to manufacturer's specifications and relevant industry codes of practice and AS/ACIFS009:2006

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Visual inspection is undertaken to confirm termination colour code sequence has been followed prior to end to end testing of wire and pair termination integrity

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Earth wires are terminated with connectors recommended by manufacturers in accordance with accepted industry codes of practice and AS/ACIFS009:2006

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Earth wire continuity is maintained through out and interface requirements with electrical systems are observed

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Earthing installation shall be tested for continuity, insulation resistance and conductive resistance as per accepted industry standards including AS/ACIFS009:2006

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Compatibility of alterations with existing systems is confirmed and new wok tested both in isolation and when integrated with existing systems

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Inspect cable route to ensure correct separations

  1. Check separations along the entirety of the cable route
  2. Rectify separations which do not comply with regulations
  3. Install barriers to achieve separations where spatial separation can't be met
Check separations along the entirety of the cable route

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Rectify separations which do not comply with regulations

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Install barriers to achieve separations where spatial separation can't be met

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Create records

  1. Complete TCA form and create NTD records
Complete TCA form and create NTD records

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Monitor work activity

  1. Supervision of cablers not holding appropriate registration for the task is maintained to ensure installation/maintenance activity is in accordance with legislative requirements for safety and network integrity including AS/ACIFS008:2006 and AS/ACIFS009:2006
Supervision of cablers not holding appropriate registration for the task is maintained to ensure installation/maintenance activity is in accordance with legislative requirements for safety and network integrity including AS/ACIFS008:2006 and AS/ACIFS009:2006

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Assessed

Teacher: ___________________________________ Date: _________

Signature: ________________________________________________

Comments:

 

 

 

 

 

 

 

 

Instructions to Assessors

Evidence Guide

The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.

Critical aspects for assessment and evidence required to demonstrate competency in this unit

Evidence of the following is essential:

Demonstration of a cabling installation including 3 types of telephone sockets, one network termination device (NTD) and one alarm panel including TCA compliance form

Accurate application of cable conductor identification codes

Conduct and interpret cable test results

Correct interpretation and application of standards and regulations

Context of and specific resources for assessment

Assessment must ensure:

A workplace conducting the operations covered by this competency unit, equipment and resources relevant to the context of the work (See Range Statement) and support from a competent supervisor or mentor.

OR

A simulated environment with similar provisions which conforms to the Assessment Guidelines.

Guidance information for assessment

Access must be provided to appropriate learning and assessment support when required.

Assessment processes and techniques must be culturally appropriate, and appropriate to the oral communication skill level, and language and literacy capacity of the candidate and the work being performed.

In all cases where practical assessment is used it will be combined with targeted questioning to assess underpinning knowledge.

Required Skills and Knowledge

Required skills

Select from the following list to suit the learning and assessment context

Codes refer to the Skills and Knowledge Register in Volume 3 of this Training Package that has detailed content guidelines for each code outlined.

CA200 Cable Installation

OH210 Occupational Health and Safety

RE210 ACMA Provider Rules, Cabler Registration, Rules and Regulations

TE210 Basic Telephony

Required knowledge

The relevant required knowledge is articulated in the above guidelines contained in the Skills and Knowledge Register included in this Training Package.

Range Statement

The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.

This unit is generally applied to the ACMA Restricted Cabling Rule coverage which is used in typical domestic premises but is also found in some small office home office and small business premises situations.

Building infrastructure

Includes, but not limited to, High Voltage power, other services, availability and suitability of existing cabling trays and fixing systems

Strategies to manage infrastructure

Includes: appropriate separations, fastening techniques, correct use of cable trays and support systems

Remote Power Feed

Applies to telecommunications services which operate at above TNV (Telecommunications Network Voltage)

Regulatory environment:

Is defined by the Overview Telecommunications Act 1997, and includes, ACMA, ACIF/CA, Labelling, Certified Components List (CCL) accredited registrars and registration

Cabling environment may include:

Indoor environments include concealed locations such as: ceilings, false ceilings, internal wall space, under floor, damp situations and within modular workstations

Outdoor environments include cable installations on external walls and underground and/or aerial cabling on private property

Underground cabling would be in an exclusive trench or shared trench with electrical LV cables and/or other utilities

Aerial telecommunications cabling shall not include installations on poles shared with LV/HV electrical power cables/terminations

Cable type:

Includes: copper twisted pair including indoor, external, aerial and underground

Cable identification

Refers to cable conductor identification codes and may be:

Colour coded, banded, numbered, lettered

Termination systems:

Includes: a range of at least 3 different socket types (Australian and US modular sockets and Mode 3 alarm sockets) and at least one network terminating device (NTD) must be individually terminated.

Note: Jumperable distributors not included in this unit requirement.

Earthing and protection

Refers to earthing for protection and surge suppression and must be treated in accordance with AS/ACIFS009:2006

Separations

Is the distance between communications cable and other services. This includes Low Voltage (LV), High Voltage (HV) - Single core and HV Multi-core, Open terminations

Regulations

Cover separations will generally be covered by Wiring Rules standard AS/ACIFS009:2006

Spatial separations

Is the distance between communications cable and other cable required by regulations where no barrier is installed

Barriers

Refers to physical barriers installed when there is not enough space to achieve spatial separations

Records:

Is a TCA form (and future NTD record cards) must conform with AS/ACIFS009:2006

Relevant legislation, codes, regulations and standards (or their replacements)

Include relevant components of:

ACMA Technical Standards

AS/ACIFS008:2006, AS/ACIFS009:2006 - or subsequent replacements

SAA Communications Cabling Manual (Restricted)

AS/NZS 3000