The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!
From the Wiki University
What evidence can you provide to prove your understanding of each of the following citeria?
Prepare for work
|
|
Applicable legislative, OHS and organisational requirements relevant to moisture testing timber and concrete are verified and complied with Completed |
Evidence:
|
Customer enquiry and relevant information is consulted to determine the type of proposed flooring operation and other work requirements Completed |
Evidence:
|
Moisture content requirements for the proposed flooring are determined from manufacturer or workplace information Completed |
Evidence:
|
Tools, equipment and required materials are obtained and prepared for the work Completed |
Evidence:
|
Conduct moisture testing on timber flooring and components
|
|
The type of floor construction materials and the building floor structure and substructure are identified Completed |
Evidence:
|
Timber flooring is visually inspected to identify irregularities in moisture content. Completed |
Evidence:
|
Ventilation flow is confirmed and irregularities noted Completed |
Evidence:
|
Floor joists, bearers and stumps are visually checked for moisture content irregularities Completed |
Evidence:
|
Moisture testing of timber flooring, floor joists, bearers and stumps EMC is completed in accordance with the approved process and standard Completed |
Evidence:
|
Conduct moisture testing on concrete floors
|
|
The type of floor construction materials and the building floor structure and substructure are identified Completed |
Evidence:
|
Concrete floor is visually inspected to identify irregularities in moisture content. Completed |
Evidence:
|
Moisture testing is completed in accordance with the approved process and Australian standard Completed |
Evidence:
|
Notify findings of moisture tests
|
|
Notification of the findings of the moisture tests is completed in accordance with the current and relevant Australian standards Completed |
Evidence:
|
Copies of the notification are sent to appropriate personnel and suitably filed following workplace procedures Completed |
Evidence:
|