NTISthis.com

Evidence Guide: LMFFL3306A - Install resilient sheet to walls

Student: __________________________________________________

Signature: _________________________________________________

Tips for gathering evidence to demonstrate your skills

The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!

From the Wiki University

 

LMFFL3306A - Install resilient sheet to walls

What evidence can you provide to prove your understanding of each of the following citeria?

Prepare for installation

  1. Applicable legislative, OHS and organisational requirements relevant to installing resilient wall coverings are verified and complied with
  2. Instructions and/or plans are read and interpreted to identify process required to complete work tasks
  3. Sub-strate condition is assessed for suitability for installation of resilient coverings to the walls
  4. Suitable adhesives, trims and accessories are selected
  5. Tools, equipment and materials are selected and checked prior to use to ensure that they are appropriate for the work, serviceable and in a safe condition
  6. Sequence of work is planned, including the starting point, to ensure efficiency and quality of installation
Applicable legislative, OHS and organisational requirements relevant to installing resilient wall coverings are verified and complied with

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Instructions and/or plans are read and interpreted to identify process required to complete work tasks

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Sub-strate condition is assessed for suitability for installation of resilient coverings to the walls

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Suitable adhesives, trims and accessories are selected

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Tools, equipment and materials are selected and checked prior to use to ensure that they are appropriate for the work, serviceable and in a safe condition

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Sequence of work is planned, including the starting point, to ensure efficiency and quality of installation

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Set-out floor coverings

  1. Resilient wall covering to be installed is checked against order
  2. Resilient wall coverings are acclimatised according to manufacturer recommendations
  3. Resilient wall coverings for fixing are organised and used in accordance with relevant safety management requirements
  4. Working lines and starting point are established
  5. Pre-form fillet is cut and fitted (if required)
  6. Feathering systems and applications are prepared and applied in accordance with the installation plan
Resilient wall covering to be installed is checked against order

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Resilient wall coverings are acclimatised according to manufacturer recommendations

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Resilient wall coverings for fixing are organised and used in accordance with relevant safety management requirements

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Working lines and starting point are established

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Pre-form fillet is cut and fitted (if required)

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Feathering systems and applications are prepared and applied in accordance with the installation plan

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Install resilient sheet

  1. Resilient wall coverings are laid out to meet directional sequence, pattern match, specification requirements and to minimise waste and joins as appropriate
  2. The aesthetics of the materials is maximised where appropriate, matching grains, colours and patterns
  3. Materials are cut to length and size, allowing for final adjustment, trimming and welding processes
  4. Header and/or perimeter contact adhesive is applied to surfaces
  5. Adhesive is applied to the body of the walls as specified by the adhesive manufacturer
  6. Resilient wall covering is positioned in accordance with the plan, pressed out and hand-rolled
  7. Resilient wall covering is heated to form required profiles
  8. Seams are prepared and welded in accordance with the plan, manufacturer instructions and industry standards
  9. Joins and/or seams are trimmed and finished to industry standards
  10. Resilient wall coverings are sealed to floor coverings, door and window frames, as well as fixtures and fittings in wet area installations
  11. Completed installation is checked for flaws in installation and materials and faults rectified following workplace procedures
Resilient wall coverings are laid out to meet directional sequence, pattern match, specification requirements and to minimise waste and joins as appropriate

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

The aesthetics of the materials is maximised where appropriate, matching grains, colours and patterns

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Materials are cut to length and size, allowing for final adjustment, trimming and welding processes

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Header and/or perimeter contact adhesive is applied to surfaces

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Adhesive is applied to the body of the walls as specified by the adhesive manufacturer

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Resilient wall covering is positioned in accordance with the plan, pressed out and hand-rolled

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Resilient wall covering is heated to form required profiles

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Seams are prepared and welded in accordance with the plan, manufacturer instructions and industry standards

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Joins and/or seams are trimmed and finished to industry standards

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Resilient wall coverings are sealed to floor coverings, door and window frames, as well as fixtures and fittings in wet area installations

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Completed installation is checked for flaws in installation and materials and faults rectified following workplace procedures

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Complete housekeeping

  1. Unused materials are stored or recycled as required
  2. Tools and equipment are cleaned and stored appropriately
  3. Work area is cleaned and rubbish disposed of appropriately
  4. Workplace documentation and/or reports are completed
Unused materials are stored or recycled as required

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Tools and equipment are cleaned and stored appropriately

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Work area is cleaned and rubbish disposed of appropriately

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Workplace documentation and/or reports are completed

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Assessed

Teacher: ___________________________________ Date: _________

Signature: ________________________________________________

Comments:

 

 

 

 

 

 

 

 

Instructions to Assessors

Evidence Guide

The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.

Critical aspects for assessment and evidence required to demonstrate competency in this unit

Comply with legislation, regulations, standards, codes of practice and established safe practices and procedures for installing resilient wall coverings

Interpret work order and locate and apply relevant information

Apply safe handling requirements for equipment, products and materials, including use of personal protective equipment

Follow work instructions, operating procedures and inspection practices to:

prevent damage to goods, equipment and products

maintain required production output and product quality

minimise the risk of injury to self and others

Complete a minimum of:

one installation of a wet wall resilient wall covering installation using a horizontal installation system including internal and external corners to walls, the covering of window reveals and sealing to door frames and fittings

one installation of a wet wall resilient wall covering installation using a vertical installation system including internal and external corners to walls, the covering of window reveals and sealing to door frames and fittings

Work effectively with others

Modify activities to cater for variations in workplace contexts and environment

Context of, and specific resources for assessment

The application of competency is to be assessed in the workplace or realistically simulated workplace

Assessment is to occur under standard and authorised work practices, safety requirements and environmental constraints

Assessment of essential underpinning knowledge, other than confirmatory questions, will usually be conducted in an off-site context

Assessment is to comply with relevant regulatory or Australian Standards requirements

The following resources should be made available:

workplace location or simulated workplace

materials and equipment relevant to installing resilient sheet to walls

specifications and work instructions

Method of assessment

Assessment must satisfy the endorsed assessment guidelines of the Furnishing Industry Training Package

Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with application of underpinning knowledge

Assessment methods must be by direct observation of tasks and include questioning on underpinning knowledge to ensure its correct interpretation and application

Assessment may be applied under project related conditions (real or simulated) and require evidence of process

Assessment must confirm a reasonable inference that competency is able not only to be satisfied under the particular circumstance, but is able to be transferred to other circumstances

Assessment may be in conjunction with assessment of other units of competency

Required Skills and Knowledge

Required skills

collect, organise and understand information related to work orders, basic plans and safety procedures

communicate ideas and information to enable confirmation of work requirements and specifications, coordination of work with site supervisor, other workers and customers, and the reporting of work outcomes and problems

work with others and in a team by recognising dependencies and using cooperative approaches to optimise work flow and productivity

use pre-checking and inspection techniques to anticipate problems installing resilient wall coverings to avoid re-work and wastage

recognise and respond to circumstances outside instructions or personal competence

plan and organise activities including the preparation and layout of the worksite and the obtaining of equipment and materials to avoid any back tracking, work flow interruptions or wastage

use mathematical ideas and techniques to correctly complete measurements, calculate area and estimate other material requirements

clarify and confirm work instructions

plan work within given task parameters

accept responsibility for given tasks

set, monitor and satisfy personal work goals

satisfy the competency requirements for the job

maintain current knowledge of:

tools and materials

installation techniques

seek learning opportunities

use the limited workplace technology related to installing resilient wall coverings including tools, equipment, calculators and measuring devices.

Required knowledge

State or Territory OHS legislation, regulations, standards and codes of practice relevant to installing resilient sheet to walls

organisational and site standards, requirements, policies and procedures for installing resilient sheet to walls

environmental protection requirements

established communication channels and protocols

problem identification and resolution

types of tools and equipment and procedures for their safe use, operation and maintenance

characteristics of materials, products and defects

set up and operation of equipment

products assembly techniques

procedures for the recording, reporting and maintenance of workplace records and information

appropriate mathematical procedures for estimation and measurement

type, characteristics, uses and limitations of:

weldable resilient wall coverings

resilient wall covering installation adhesives

types and uses of resilient wall covering installation tools and equipment

workplace safety system requirements related to resilient wall covering installation

characteristics and requirements of sub-strate preparation for wall coverings

work flow in relation to fixing, welding and finishing of resilient wall coverings

Range Statement

The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.

Legislative requirements

are to be in accordance with applicable legislation from all levels of government that affect organisational operation. Requirements may include but not be limited to award and enterprise agreements, industrial relations, Australian Standards, confidentiality and privacy, OHS, the environment, equal opportunity, anti-discrimination, relevant industry codes of practice, duty of care and heritage

OHS requirements

are to be in accordance with Commonwealth, State or Territory legislation and regulations, organisational safety policies and procedures. Requirements may include but not be limited to the use of personal protective equipment and clothing, fire fighting equipment, First Aid equipment, hazard and risk control and elimination, control of hazardous materials and substances, manual handling including lifting and carrying

Organisational requirements

may include but not be limited to legal, organisational and site guidelines, policies and procedures relating to own role and responsibility, quality assurance, procedural manuals, quality and continuous improvement processes and standards, OHS, emergency and evacuation, ethical standards, recording and reporting, access and equity principles and practices, equipment use, maintenance and storage, environmental management (waste disposal, recycling and re-use guidelines)

Resilient wall coverings

may be:

homogeneous/heterogeneous

linoleum sheet

encapsulated glass fibre

inlaid

rotogravure

Instructions

Workplace procedures relating to the use and operation of tools and equipment

Workplace instructions, including job sheets, plans, drawings and designs

Workplace procedures relating to reporting and communications

Manufacturer instructions for the use of equipment and materials

Adhesives

are to include, but may not be limited to acrylic adhesives and water and solvent based contacts recommended by manufacturers

Tools and equipment

may include flat trowel, notched trowel, pencil cove roller, wall roller, hand roller, cove and corner roller, recess scriber, hook and straight knife, chalk line, spirit level, tape measure, water level, laser level, height gauge, wall trolley, contact bucket/tray/roller brushes, scaffolding and step ladder

Materials

are to include but are not limited to resilient wall coverings, skirting, reducing and edge strips, welding rod, coving accessories, tapes, pattern paper, fillers and adhesives

Feathering systems

are to include the fitment of PVC edge fillet diminishing strip and the use of pre-mixed or mixed cementitious compounds

Welding

is to include rod welding, self welding and fusion

Profiles

are to include internal and external angles, bullnoses, coves and may include profiling to pipe work

Trimmed and finished

is to include trimming weld rod, abrading and fusing external corners and chemically finishing to industry standards and manufacturer specifications

Sealed

is to include the sealing of the resilient wall coverings at door and window frames, pipes, fixtures, fittings and floor coverings