The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!

From the Wiki University

 

MEM07034A - Operate and monitor intermediate class boiler

What evidence can you provide to prove your understanding of each of the following citeria?

Carry out pre-operational checks

  1. Pre-operational checks of boiler and associated equipment are carried out according to standard operating procedures.
  2. Maintenance requirements are identified and reported in accordance with standard operating procedures.
Pre-operational checks of boiler and associated equipment are carried out according to standard operating procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Maintenance requirements are identified and reported in accordance with standard operating procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Maintain health and safety standards in work area

  1. Hazards and potential hazards in work area are identified and reported in accordance with statutory requirements and workplace procedures.
  2. Personal protective equipment and clothing is selected and used as appropriate, according to statutory requirements and workplace procedures.
  3. Hazard prevention/control measures are selected and used as required, in accordance with statutory requirements and workplace procedures
Hazards and potential hazards in work area are identified and reported in accordance with statutory requirements and workplace procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Personal protective equipment and clothing is selected and used as appropriate, according to statutory requirements and workplace procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Hazard prevention/control measures are selected and used as required, in accordance with statutory requirements and workplace procedures

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Start up boiler

  1. Boiler is started and brought on line safely, consistent with workplace procedures and production requirements.
Boiler is started and brought on line safely, consistent with workplace procedures and production requirements.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Conduct hand-over/take-over procedures

  1. Operating status of the boiler is confirmed in accordance with manufacturer's recommendations and workplace procedures.
  2. Boiler status and operation is communicated according to workplace procedures and statutory requirements.
Operating status of the boiler is confirmed in accordance with manufacturer's recommendations and workplace procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Boiler status and operation is communicated according to workplace procedures and statutory requirements.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Operate and monitor intermediate class boiler and associated equipment

  1. The boiler and associated equipment is operated and monitored consistent with production and safety requirements.
  2. Boiler water quality tests are conducted to manufacturer's recommendations and workplace procedures.
  3. Water quality is maintained according to manufacturer's recommendations and workplace procedures.
  4. Boiler failures and emergencies are responded to in accordance with statutory requirements, manufacturer's recommendations and workplace procedures.
The boiler and associated equipment is operated and monitored consistent with production and safety requirements.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Boiler water quality tests are conducted to manufacturer's recommendations and workplace procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Water quality is maintained according to manufacturer's recommendations and workplace procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Boiler failures and emergencies are responded to in accordance with statutory requirements, manufacturer's recommendations and workplace procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Shut down boiler and associated equipment

  1. Operational shut-downs of boiler and associated equipment are carried out in accordance with work-place procedures, production and safety requirements.
  2. Shut-downs of boiler and associated equipment for internal inspection are carried out in accordance with workplace procedures, production and safety requirements.
  3. Boiler is isolated in accordance with statutory requirements, manufacturer's recommendations and workplace procedures.
  4. Boiler is cleaned internally and externally to manufacturer's recommendations and workplace procedures.
Operational shut-downs of boiler and associated equipment are carried out in accordance with work-place procedures, production and safety requirements.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Shut-downs of boiler and associated equipment for internal inspection are carried out in accordance with workplace procedures, production and safety requirements.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Boiler is isolated in accordance with statutory requirements, manufacturer's recommendations and workplace procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Boiler is cleaned internally and externally to manufacturer's recommendations and workplace procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Store boiler in shut-down mode

  1. Appropriate storage mode is identified
  2. Boiler and associated equipment is stored in shut-down mode to manufacturer's recommendations and workplace procedures.
Appropriate storage mode is identified

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Boiler and associated equipment is stored in shut-down mode to manufacturer's recommendations and workplace procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Assessed

Teacher: ___________________________________ Date: _________

Signature: ________________________________________________

Comments:

 

 

 

 

 

 

 

 

Instructions to Assessors

Evidence Guide

The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.

Overview of assessment

A person who demonstrates competency in this unit must be able to operate and monitor intermediate class boilers. Competency in this unit cannot be claimed until all prerequisites have been satisfied.

Critical aspects for assessment and evidence required to demonstrate competency in this unit

Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.

Context of and specific resources for assessment

This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is the candidate is not in productive work, then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.

This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with operating and monitoring intermediate class boilers or other units requiring the exercise of the skills and knowledge covered by this unit.

Method of assessment

Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning should not require language, literacy and numeracy skills beyond those required in this unit. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.

Guidance information for assessment

Required Skills and Knowledge

Required skills

Look for evidence that confirms skills in:

following, standard operating procedures and statutory requirements

performing preoperational checks of boiler

performing maintenance checks

orally reporting routine information

identifying hazards, hazardous situations and control measures

using personal protective clothing and equipment

selecting the most appropriate prevention/control measure for a given situation

starting up boilers, including those fitted with associated equipment such as superheaters and economisers

monitoring boilers, including checks of combustion management system and superheater and economiser operation

checking operating status

recording routine and familiar information in operating log and other standard workplace forms

performing water quality tests to manufacturer's recommendations and workplace procedures

using testing equipment

adjusting water quality

responding to typical emergency situations

notifying downstream users

performing operational and inspection shut-down, including procedures for associated equipment, such as superheaters and economisers

isolating boiler from any common connection between the boiler and other boilers on line and all access points required for inspection

Required knowledge

Look for evidence that confirms knowledge of:

pre-operational checks

procedures for identifying and reporting maintenance requirements

statutory requirements and workplace procedures for identifying and reporting hazards in the work area

use and application of personal protective equipment

safe work practices and procedures

prevention and control measures

the processes for starting a boiler such as heat input, warm up of the reticulation system, steam traps and steam line purge, systems operation, reticulation line pressure, steam usage and supply, associated equipment such as superheaters and economisers

the process for confirming operational status of boiler

procedures for maintaining an operating log and communicating boiler status

procedures for communicating boiler status and operation

principles of intermediate boiler operation - single and battery

boiler fittings

preparing boiler for inspection

feed water systems and treatment, including de-aerator function and purpose

procedures for monitoring an intermediate class boiler, such as steam reticulation line pressure, usage, supply and quality of steam, combustion/heat source system, feed water system, fuel system, combustion air supply, water level, boiler steam pressures and operation of control/safety devices, combustion management system, associated equipment such as superheaters and economisers

function, purpose and location of associated equipment:

superheater

economiser

air heater

feed water heater

attemperator

superheater safety valves

economiser relief valves

main steam stop valve

procedures for conducting boiler water quality tests

procedures for adjusting boiler water quality

procedures such as identification of emergency isolation of heat source, operation of boiler, selection and application of fire fighting equipment and notification of downstream users

operational shut-down processes and procedures such as confirming water level, cooling down, boiler pressure/vacuum and fuel/heat source isolation

shut-down processes and procedures for internal inspection, such as confirming boiler cooling down, vacuum/pressure, fuel/heat source isolation, removal of combustion equipment and water from boiler

isolation procedures and safety issues

procedures for cleaning boiler internally and externally

various modes of boiler storage, which may include integral associated equipment such as superheaters and economisers

the reasons for selecting particular storage mode

procedures for storing a boiler in shut-down mode

Range Statement

The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.

Pre-operational checks

Feed water supply, boiler water level, fuel supply/heat source, boiler valves - their operation and position, combustion air supply and combustion equipment

Boiler

Modulating combustion air supply, modulating single heat source, modulating firing rate, and or superheaters, economisers, single and battery

Hazards

Chemical and thermal hazards, manual handling, machine guarding, illumination of work area, rubbish and combustible materials, steam and fuel leaks etc.

Associated equipment

Superheater, superheater safety valves, economiser, economiser relief valves, air heater, feed water heater, attemperator, main steam stop valve

Monitored

Steam pressure, flame and combustion conditions, feed system and condensate returns, fuel system, water level, combustion management system, water management system, boiler and steam manifold fittings, soot blowers

Storage mode

Wet and dry storing, open or closed condition