The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!

From the Wiki University

 

MEM10023 - Design and connect control switching of circuits for building services and industrial equipment

What evidence can you provide to prove your understanding of each of the following citeria?

Determine job requirements

  1. Follow standard operating procedures (SOPs)
  2. Comply with work health and safety (WHS) requirements at all times, including appropriate risk control measures
  3. Use appropriate personal protective equipment (PPE) in accordance with SOPs
  4. Identify job requirements from specifications, drawings, job sheets or work instructions
Follow standard operating procedures (SOPs)

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Comply with work health and safety (WHS) requirements at all times, including appropriate risk control measures

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Use appropriate personal protective equipment (PPE) in accordance with SOPs

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Identify job requirements from specifications, drawings, job sheets or work instructions

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Design control switching of circuits

  1. Design agreed control switching of circuits to comply with specifications and regulatory requirements
  2. Document agreed design of control circuits in accordance with procedures
  3. Obtain the necessary tools, equipment, test instruments and materials needed to connect the control circuits
Design agreed control switching of circuits to comply with specifications and regulatory requirements

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Document agreed design of control circuits in accordance with procedures

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Obtain the necessary tools, equipment, test instruments and materials needed to connect the control circuits

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Connect control switching of circuits

  1. Isolate and tag circuits and equipment in accordance with procedures, where required
  2. Terminate and connect control circuit components to comply with the design and regulatory requirements
  3. Functional test control circuit operation to ensure compliance with agreed design
  4. Rectify any non-compliances and re-test to meet requirements
  5. Terminate and connect control circuits
  6. Test control circuits to ensure functionality
  7. Document control circuits in accordance with SOPs
Isolate and tag circuits and equipment in accordance with procedures, where required

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Terminate and connect control circuit components to comply with the design and regulatory requirements

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Functional test control circuit operation to ensure compliance with agreed design

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Rectify any non-compliances and re-test to meet requirements

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Terminate and connect control circuits

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Test control circuits to ensure functionality

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Document control circuits in accordance with SOPs

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Assessed

Teacher: ___________________________________ Date: _________

Signature: ________________________________________________

Comments:

 

 

 

 

 

 

 

 

Instructions to Assessors

Evidence Guide

Elements describe the essential outcomes.

Performance criteria describe the performance needed to demonstrate achievement of the element.

1.

Determine job requirements

1.1.

Follow standard operating procedures (SOPs)

1.2.

Comply with work health and safety (WHS) requirements at all times, including appropriate risk control measures

1.3.

Use appropriate personal protective equipment (PPE) in accordance with SOPs

1.4.

Identify job requirements from specifications, drawings, job sheets or work instructions

2.

Design control switching of circuits

2.1.

Design agreed control switching of circuits to comply with specifications and regulatory requirements

2.2.

Document agreed design of control circuits in accordance with procedures

2.3.

Obtain the necessary tools, equipment, test instruments and materials needed to connect the control circuits

3.

Connect control switching of circuits

3.1.

Isolate and tag circuits and equipment in accordance with procedures, where required

3.2.

Terminate and connect control circuit components to comply with the design and regulatory requirements

3.3.

Functional test control circuit operation to ensure compliance with agreed design

3.4.

Rectify any non-compliances and re-test to meet requirements

3.5.

Terminate and connect control circuits

3.6.

Test control circuits to ensure functionality

3.7.

Document control circuits in accordance with SOPs

Required Skills and Knowledge

Elements describe the essential outcomes.

Performance criteria describe the performance needed to demonstrate achievement of the element.

1.

Determine job requirements

1.1.

Follow standard operating procedures (SOPs)

1.2.

Comply with work health and safety (WHS) requirements at all times, including appropriate risk control measures

1.3.

Use appropriate personal protective equipment (PPE) in accordance with SOPs

1.4.

Identify job requirements from specifications, drawings, job sheets or work instructions

2.

Design control switching of circuits

2.1.

Design agreed control switching of circuits to comply with specifications and regulatory requirements

2.2.

Document agreed design of control circuits in accordance with procedures

2.3.

Obtain the necessary tools, equipment, test instruments and materials needed to connect the control circuits

3.

Connect control switching of circuits

3.1.

Isolate and tag circuits and equipment in accordance with procedures, where required

3.2.

Terminate and connect control circuit components to comply with the design and regulatory requirements

3.3.

Functional test control circuit operation to ensure compliance with agreed design

3.4.

Rectify any non-compliances and re-test to meet requirements

3.5.

Terminate and connect control circuits

3.6.

Test control circuits to ensure functionality

3.7.

Document control circuits in accordance with SOPs

Evidence required to demonstrate competence in this unit must be relevant to and satisfy the requirements of the elements and performance criteria on at least two (2) occasions and include:

following work instructions, standard operating procedures (SOPs) and safe work practices

identifying and interpreting circuits, drawings, plans and specifications relevant to the work to be undertaken

determining the electrical and non-electrical isolation requirements to prevent the creation of hazards linked from the loss of machine/system/process control according to established procedures

using lock out tag procedures with appropriate tags/signs

proving electrical isolation and following established safety rules prior to working on electrical equipment or wiring

ensuring all electrical equipment and tools are tested and tagged and are up to date

developing according to specifications at least five (5) or more of the following control circuit designs:

multiple light switching circuit

master control circuit

local start-stop control and with electrical interlocking

connecting a timer in a controlled circuit

a multiple motor starting circuit which incorporates start, stop and jog control

machine safety circuit

line conditioners

inverters

uninterrupted power supplies (UPS)

energy management systems

terminating and connecting to comply with the above selected control circuit scenarios and regulatory requirements at least five (5) or more of the following control circuit devices:

multi-way switches

switches with more than two positions and Off

push buttons

electromechanical relays

programmable relays

contactors

motor reversing contactors

three-phase starters

reduced voltage starters

transducers/sensors, including:

limit, proximity, float and pressure switches

photoelectric cells

light and temperature sensors

programming timers and using the monitoring facility of the programmable relay to verify the values of the timer

testing connected control circuit devices as against agreed design and rectifying any non-compliant functions

complying with the Australian/New Zealand Wiring Rules and local supply requirements for three-phase motor installations and starters

testing control circuits to ensure functionality

using test equipment to locate faults, completing remedial action and retesting to ensure compliance

documenting connected control circuits in accordance with SOPs.

Evidence required to demonstrate the required knowledge for this unit must be relevant to and satisfy the requirements of the elements and performance criteria and include knowledge of:

safe work practices and procedures and use of personal protective equipment (PPE)

electrical drawings – conventions in linework, symbols used in electrical circuit diagrams, placement and arrangement of circuit components

drawing schematic circuit diagrams complying with Australian Drawing Standard AS/NZS 1102.101-1989 Graphical symbols for electrotechnical documentation – General information and general index, and converting to wiring diagrams

construction and operation of contactors and relays with various types of contacts, including:

normally open

normally closed

timed on closing

timed in opening

timed in both closing and opening

drawing contactors in circuits and drawing conventions applied

control diagrams drawn as ladder diagrams where the ladder stiles are the supply lines and the ladder rungs are the various circuit lines

control circuit variations, including:

two-position control

local or remote operation

two-wire control

two-wire and push button control where extra start push-buttons are all placed in parallel and where extra stop push-buttons are placed in series

reversing circuits – use of mechanical and electrical interlocks

jogging control

common control devices used in circuits, including:

multi-way switches

switches with more than two positions and Off

push buttons

electromechanical relays

programmable relays

contactors

motor reversing contactors

three-phase starters

reduced voltage starters

transducers/sensors, including:

limit, proximity, float and pressure switches

photoelectric cells

light and temperature sensors:

programmable timers, including specifications to be met and functions to be controlled including machine operation or process output

line conditioners and the purpose they provide

inverters and the purpose they provide

energy management systems and the purpose they provide

static electricity discharge or electrostatic discharge and the hazards associated and the precautions to be taken.

Range Statement

This field allows for different work environments and conditions that may affect performance. Essential operating conditions that may be present (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) are included.

Control switching of circuits include five (5) or more of the following:

multiple light switching circuit

master control circuit

local start-stop control and with electrical interlocking

connecting a timer in a controlled circuit

a multiple motor starting circuit which incorporates start, stop and jog control

machine safety circuit

line conditioners

inverters

uninterrupted power supplies (UPS)

energy management systems

Control circuit components include five (5) or more of the following:

multi-way switches

switches with more than two positions and Off

push buttons

electromechanical relays

programmable relays

contactors

motor reversing contactors

three-phase starters

reduced voltage starters

transducers/sensors, including:

limit, proximity, float and pressure switches

photoelectric cells

light and temperature sensors

Regulatory requirements include:

AS/NZS 3000:2007 Electrical Installations (known as the Australian/New Zealand Wiring Rules

Safe working practices include:

demonstration of safe working practices and installation in accordance with industry established safe and sound practices