The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!
From the Wiki University
What evidence can you provide to prove your understanding of each of the following citeria?
Identify job requirements
|
|
The measurement to be made is determined from instructions/plans and relevant job specifications. Completed |
Evidence:
|
Drawing information is interpreted correctly, datums established and the range of tolerances applying to components is understood. Completed |
Evidence:
|
Set up/orient components
|
|
Pre-start checks are undertaken to standard operating procedures. Completed |
Evidence:
|
Correct safety procedures are observed and all equipment is checked for safe operation. Completed |
Evidence:
|
The most appropriate method of clamping/support is determined to minimise distortion and maximise measuring access. Completed |
Evidence:
|
Component/fixture/clamping devices are correctly set up and oriented. Completed |
Evidence:
|
Select and activate part programs
|
|
Part program is identified according to standard operating procedures as required. Completed |
Evidence:
|
Part program is verified. Completed |
Evidence:
|
Selected part program is activated according to standard operating procedures. Completed |
Evidence:
|
Prepare CMM
|
|
Probe configuration is determined according to specifications. Completed |
Evidence:
|
Probe configuration is adjusted on coordinate measuring machine according to standard operating procedures. Completed |
Evidence:
|
Probe angles are checked for compliance and adjusted as required. Completed |
Evidence:
|
CMM is re-set/re-calibrated. Completed |
Evidence:
|
Probes are manually aligned for one-off components. Completed |
Evidence:
|
Edit part programs
|
|
Part program is edited to compensate for errors or changes to component specifications. Completed |
Evidence:
|
Measure components
|
|
Components are measured and checked for conformance to specification. Completed |
Evidence:
|
Data/report is produced Completed |
Evidence:
|