The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!
From the Wiki University
What evidence can you provide to prove your understanding of each of the following citeria?
Install and remove domestic refrigeration and air conditioning appliances
|
|
Appliance location is identified and sited in accordance with customer requirements, regulations, standards, codes of practice and industry guidelines Completed |
Evidence:
|
Site is prepared for installation of appliance Completed |
Evidence:
|
Appliance is installed and secured in accordance with manufacturer instructions and industry best practice Completed |
Evidence:
|
Operation of the appliance is checked in accordance with manufacturer instructions Completed |
Evidence:
|
Waste materials and products are disposed of in accordance with Commonwealth and State legislation, environmental and industry codes of practice Completed |
Evidence:
|
Determine operating condition of domestic refrigeration and air conditioning appliances
|
|
Established procedures and standard electrical tests are carried out to determine actual operating condition Completed |
Evidence:
|
Established OHS risk control measures and procedures are followed to enable the system to be isolated and checked where necessary Completed |
Evidence:
|
Tools, equipment and testing devices needed to determine the basic refrigeration operating conditions are obtained and checked for correct operation and safety Completed |
Evidence:
|
Industry codes of practice and manufacturer service instructions are followed Completed |
Evidence:
|
Carry out routine maintenance of domestic refrigeration and air conditioning appliances
|
|
Safety hazards are identified and recorded and established risk control measures implemented Completed |
Evidence:
|
Routine maintenance procedure is performed as per manufacturer and client scheduling Completed |
Evidence:
|
Routine maintenance records are maintained and faults recorded Completed |
Evidence:
|
Fault-find and troubleshoot domestic refrigeration and air conditioning appliance faults
|
|
OHS requirements are determined Completed |
Evidence:
|
Equipment and testing devices needed to determine fault are selected Completed |
Evidence:
|
Apply standard test procedures to determine faults against equipment specifications Completed |
Evidence:
|
Test data and faults are recorded as required Completed |
Evidence:
|
Replace, repair or service faulty components in domestic refrigeration and air conditioning appliances
|
|
Plug in appliance is electrically disconnected or arrangements made for appropriately licensed person to isolate hard-wired appliances Completed |
Evidence:
|
Electrical components are replaced in accordance with manufacturer recommendation and industry best practice Completed |
Evidence:
|
Refrigeration system replacement components are selected and prepared Completed |
Evidence:
|
Refrigerants are recovered, stored and disposed of in accordance with Commonwealth legislation and industry codes of practice Completed |
Evidence:
|
Refrigeration system components are installed in accordance with industry best practice, standards and codes Completed |
Evidence:
|
Refrigeration system is returned to operating condition using standard refrigeration return to service procedures Completed |
Evidence:
|
Return to service domestic refrigeration and air conditioning appliances
|
|
Standard electrical tests are applied to identify electrical faults before operating Completed |
Evidence:
|
Appliance is started and operated in accordance with manufacturer standards Completed |
Evidence:
|
Standard tests are carried out to confirm system performance to manufacturer specifications Completed |
Evidence:
|
Appliance operating data is recorded as required Completed |
Evidence:
|
Worksite is cleaned and left in presentable condition in accordance with original presentation, client requirements, industry standards and organisational requirements Completed |
Evidence:
|