current industry standards, practices and technologies, including: classification of light distribution and beam spread electrical function and components appropriate for the insulation class or extra-low voltage (ELV) fault protection, including supply terminals, lamp holder(s), electrical ancillaries when needed and appropriated internal wiring fluorescent lamps types and principles high intensity discharge (HID) lamps illumination and lighting principles incandescent lamp types and principles ingress protection (IP) ratings and examples of their application to luminaires light-emitting diode (LED) lamps types and principles light distribution and reading a polar luminance distribution curve light output ratio of common typical luminaires without and with reflector and diffuser mechanisms lighting technology luminaires (light fittings) types and principles mechanical function and components (including IP rated enclosure with suitable mounting arrangement, mechanisms to accommodate lamp(s), electrical ancillaries when needed, optical system and excessive temperature rise) technology of light, including: electromagnetic spectrum and visible (frequency/wavelength) range light output from a source, including luminous flux, and efficacy of different types of lamps terms, units, definitions, and symbols used for: light intensity and the relationship with luminous flux illuminance and the relationship with luminous flux and environmental factors luminance and the relationship with luminous intensity and illuminance significance of inverse square law on illuminance vision and illuminance standards for particular environments and activities nature of light, including: colour rendering, colour distortion, colour temperature scale and the perceived colour of a light source comparison of the colour spectrum of sunlight and light generated from different lamp types frequency and colour that light is perceived, including primary and additive colours incandescent lamps, including: application, types, principles, common power ratings and features, including envelope, filament type and temperature (K), fill gas and cap effect of filament evaporation over time and parameters (ϕ, η, P, hr) with variations in rated voltage fluorescent lamps, including: application compact fluorescent (CFL) types, including integrated and non-integrated ballasts, form, and rating for equivalent light out of general lighting service (GLS) lamp expectations (efficacy [l/w]; visual ambience [K]; visual satisfaction [CRI] and life [hr]) type T accessories, including the basic operation, features and advantage of the electromagnetic ballast; and starter capacitor type T series, including the basic principle, double and single phosphor coating and colour rendering index (CRI) high-intensity discharge (HID) lamps, including: application mercury lamp types, including blended and high-pressure (HP) metal halide lamp, including principles, structural features, lamp forms, spectral intensity and CRI structural features and spectral intensity LED lamps, including applications, types, structural features, spectral intensity and CRI optical function and components, including a variety of mechanism to distribute light, direct light, filter light and/or limit glare; and maximum possible light output ratio relevant luminaires for indoor and outdoor applications types and features of indoor luminaires, including light distribution, symmetry, screening and utilisation factor luminaires - light fittings, including: classification of light distribution and beam spread electrical ancillaries when needed, including optical system and excessive temperature rise electrical function and components that must be appropriate for the insulation class or ELV fault protection, including supply terminals, lamp holders, electrical ancillaries when needed, and appropriated internal wiring examples of currently available luminaires for indoor and outdoor applications IP ratings and examples of their application to luminaires light distribution and reading a polar luminance distribution curve light output ratio of common typical luminaires without and with reflector and diffuser mechanisms mechanical function and components for IP rated enclosure with suitable mounting arrangement; mechanisms to accommodate lamps optical function and components, including a variety of mechanisms to distribute, direct, and filter light and/or limit glare to achieve the maximum possible light output ratio types and features of indoor luminaires, including light distribution, symmetry, screening and utilisation factor types and features of outdoor luminaires, including types of light distribution and reflector control interpersonal and communication skills, including listening, questioning and receiving feedback relevant job safety assessments or risk mitigation processes, including safe working practices relevant lighting manufacturer specifications relevant WHS/OHS legislated requirements relevant workplace documentation relevant workplace policies, procedures and instructions sustainable energy principles and practices. |