The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!

From the Wiki University

 

UEEEL0080 - Plan and analyse wiring systems, circuits, control and protection for electrical installations

What evidence can you provide to prove your understanding of each of the following citeria?

Prepare to plan and analyse wiring systems, circuits, control and protection

  1. The scope and nature of the electrical installation is determined from job specifications
The scope and nature of the electrical installation is determined from job specifications

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Load requirements for individual current using equipment are determined from job specifications and/or consultation with appropriate people

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Cable routes, the route lengths of cable, and the conditions in which the wiring system is to operate is determined from job specifications or from consultation with appropriate people

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Evaluate and plan electrical circuits, control and protection

  1. Circuits, control and protective devices are planned to ensure safe and functional operation of the installation and to comply with relevant requirements
Circuits, control and protective devices are planned to ensure safe and functional operation of the installation and to comply with relevant requirements

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Earthing is planned to comply with the multiple earthed neutral (MEN) system requirements

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Protective devices are selected to meet the required switching and tripping currents, coordination and discrimination for overload and short circuit protection in accordance with relevant industry technical standards

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Residual current devices (RCDs) are planned to meet the required circuit switching and tripping currents, in accordance with relevant industry technical standards

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Switchgear/control gear is planned to meet current and voltage requirements and confirmed suitable for environmental conditions (ingress protection (IP) ratings) and functional requirements

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Switchboards are planned to accommodate control and protective devices, links, safety services and other distributor equipment in accordance with relevant industry technical standards

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Plan wiring systems and cables for general electrical installations

  1. Wiring system is planned and suitable for the environments in which it will operate
Wiring system is planned and suitable for the environments in which it will operate

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Cable conductor sizes are planned to meet current carrying capacity requirements and voltage drop and earth fault loop impedance limitations in accordance with relevant industry standards

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Circuit protective devices are planned to meet requirements for co-ordination with conductor current carrying capacity in accordance with relevant industry standards

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Earthing system components are planned to meet multiple earthed neutral (MEN) system in accordance with relevant industry standards

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Document electrical installation wiring systems, circuits, control and protection

  1. Rationale for device and wiring system planning and calculations are documented
Rationale for device and wiring system planning and calculations are documented

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Manufacturer data is referenced in planning of equipment to ensure materials comply with safety requirements and relevant industry standards

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Electrical installation arrangement and specifications for all items are documented

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Assessed

Teacher: ___________________________________ Date: _________

Signature: ________________________________________________